Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 05, 2019 FBO #6433
SOURCES SOUGHT

79 -- WALK-BEHIND FLOOR SCRUBBERS

Notice Date
7/3/2019
 
Notice Type
Synopsis
 
NAICS
333318 — Other Commercial and Service Industry Machinery Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 10;8888 Keystone Crossing;Suite 1100;Indianapolis IN 46240
 
ZIP Code
46240
 
Solicitation Number
36C25019Q1024
 
Response Due
7/18/2019
 
Archive Date
8/17/2019
 
Point of Contact
317-988-1523
 
Small Business Set-Aside
N/A
 
Description
This is a REQUEST FOR INFORMATION (RFI) only pertaining to brand name or equal equipment and supplies for the VA medical center located at 2121 Lave Ave. Fort Wayne, IN 46953. If a solicitation is issued, the Government will do so in accordance with Federal Acquisition Circular (FAC) 2005-94, 2005-95/ 01-19-2017, FAR Part 13, Simplified Acquisition Procedures. The North American Industry Classification System (NAICS) number is 333318 and the NAICS size is 1,000 employees. The PSC is 7910. Information gathered during this request for information may be used in a small business set aside. Any concern that believes they are capable and desires to claim preference for small business status must be registered with the SBA at http://web.sba.gov/pro-net/. Any contractor that believes they are capable and desires to claim preference for veteran owned small business status must be registered with the VIP at https://www.vip.vetbiz.gov as an SDVOSB or VOSB. Responses shall include: (1) Business Name and Address, (2) FSS Contract Number (3) Vendor Point of Contact Name, Phone Number and E-mail Address (4) DUNS and NAICS code (5) Business Size (6) Type of Business: service disabled veteran owned, veteran owned small business, 8a, HUBZone, woman-owned, etc. (7) If the concern is the manufacture and the sole distributor, the concern shall provide documentation supporting the claim. Contractors that deem themselves capable of meeting the requirement shall provide the below information to John Saunders, Contracting Officer, at Kenneth.Stephend4@va.gov no-later-than Thursday, July 18, 2019 at 4:30PM, EST referencing RFQ1306528. Contractor must be registered with https://www.sam.gov Supplies are to include only TAA compliant items. Items that are not TAA compliant must be clearly identified by the contractor on the contractor s quote should a solicitation be subsequently issued. FOB is Destination. Delivery is needed 30 days ARO. Delivery is to: VAMC Fort Wayne 2121 Lake Ave. Fort Wayne, IN 46805 PLEASE SEE THE BELOW FOR THIS REQUIREMENT Salient Characteristics The walk behind orbital scrubber should have the following salient characteristics: Electrically charge the water so that it has alkaline and acid steams to attack dirt. This allows for no chemicals to be needed for cleaning. It also lowers the amount of water needed. 20 orbital cleaning area 24 V DC battery operated On board 120 V AC charger Minimum solution tank size of 11 gallons Minimum recover tank size of 14 gallons Maximum length of 49 Maximum width of 21 Maximum height of 43 Maximum weight without batteries of 270 pounds Minimum pad speed of 2000 RPM Minimum scrub motor size of 0.6 hp Minimum vacuum motor size of 0.6 hp Minimum vacuum water lift of 34.5 The walk behind cylindrical scrubber should have the following salient characteristics: Electrical charge the water so that it has alkaline and acid steams to attack dirt. This allows for no chemicals to be needed for cleaning. It also lowers the amount of water needed. 20 cylindrical cleaning head 24 V DC battery operated On board 120 V AC charger Minimum solution tank size of 11 gallons Minimum recover tank size of 14 gallons Maximum length of 51 Maximum width of 25 Maximum height of 43 Maximum weight without batteries of 270 pounds Minimum brush speed of 1000 RPM Minimum scrub motor size of 1 hp Minimum vacuum motor size of 0.5 hp Minimum vacuum water lift of 34.5 NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (03-JUL-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/InVAMC538/InVAMC538/36C25019Q1024/listing.html)
 
Record
SN05359965-F 20190705/190703230020 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.