SOURCES SOUGHT
65 -- Tissue Dissociator
- Notice Date
- 7/12/2019
- Notice Type
- Synopsis
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- Department of Veterans Affairs;Ann Arbor Healthcare System;Network Contracting Office 10;2215 Fuller Road;Ann Arbor MI 48105
- ZIP Code
- 48105
- Solicitation Number
- 36C25019Q1109
- Response Due
- 7/26/2019
- Archive Date
- 8/10/2019
- Point of Contact
- john.mccallum3@va.gov
- Small Business Set-Aside
- N/A
- Description
- This Sources Sought/Market Survey Notice is being conducted by Network Contracting Office (NCO) 10, PO Box 492, Ann Arbor, MI 48106 to identify sources that can provide and install an AUTOMATED TISSUE DISSOCIATOR for the VA Ann Arbor Healthcare System, 2215 Fuller Road, Ann Arbor, MI, 48105. Background The Ann Arbor VA requires an automated tissue dissociator for use in isolating immune cells from melanoma tumors. The dissociator shall be able to perform flow cytometry, transcriptome analysis, and adoptive transfers, and be capable of isolating CD8+ T cells and other tumor-infiltrating lymphocytes without disrupting cellular integrity. The tissue dissociator shall be able to process up to 8 tissue samples at a time, with customizable programs for incubation temperature (37 C, time, speed (+20-+4,000 rpm), Rotation direction (clockwise, counter-clockwise), loop cycles and ramp time (time to reach certain speed). The tissue dissociator shall be able to program each sample independently and run all eight simultaneously. Functionality The tissue dissociator shall be capable of providing the following functions: Be capable of isolating CD8+ T cells and other tumor-infiltrating lymphocytes without disrupting cellular integrity Must be able to accommodate samples from 300 microliters to 10 mL total volume, and 20 to 4000 mg of tissue Provide analysis by flow cytometry, transcriptome analysis, and adoptive transfers must be programmable for custom workflows for the following criteria; Temperature (heated or not) Time of incubation Speed (+20-+4,000 rpm) Rotation direction (clockwise, counter-clockwise) Loop cycles Time to reach certain speed (ramp time) Must be able to run 8 samples simultaneously Each sample must be able to be programmed independently The heat source must be capable of heating all eight samples at to 37 degrees C (incubation temperature) Warranty and Service The equipment shall include a warranty for repair service to address any instrument defects and parts and labor for necessary repairs. Technical support and software upgrades shall be included as well. Security The C&A requirements do not apply, and a Security Accreditation Package is not required. No sensitive data will be stored on the device. The device will not be connected to the VA network nor will it have access to sensitive patient data. Installation The contractor shall be responsible for installing the device in the research lab in room 112 of building 31 at the VA Ann Arbor Healthcare System in Ann Arbor, located at 2215 Fuller Road, Ann Arbor MI, 48105. Response If your business can provide the above required equipment and installation, please respond to this Sources Sought inquiry by Friday, July 26, 2019 at 4:30 PM EDT. Emails only accepted that reference subject: RFI 36C25019Q1109 SOURCES SOUGHT TISSUE DISSOCIATOR Responses should include: (1) Business name, GSA contract number (if applicable) and address (2) Point of contact name, phone number, and E-mail address (3) DUNS number and NAICS code (4) Business size, i.e. SMALL or LARGE (5) Type of business, i.e. Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), 8A, HUB Zone, Women Owned Small Business (WOSB), etc. (6) Capability statement All businesses capable of providing the required products and installation are encouraged to reply to this request for information as this may be used to determine potential set-asides for this request. E-mail responses to: John McCallum john.mccallum3@va.gov (Note: This is NOT A REQUEST FOR QUOTE or an announcement of a solicitation.) NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (12-JUL-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/spg/VA/VAAAHCS506/VAAAHCS506/36C25019Q1109/listing.html)
- Place of Performance
- Address: Department of Veterans Affairs;VA Ann Abor Healthcare System;2215 Fuller Rd. Building 1;Ann Arbor, MI
- Zip Code: 48105-2303
- Country: USA
- Zip Code: 48105-2303
- Record
- SN05368275-F 20190714/190712230025 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |