Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 17, 2019 FBO #6445
SOLICITATION NOTICE

Z -- Provide Emergency Power to Telecommunication Rooms/603-18-601

Notice Date
3/27/2019
 
Notice Type
Synopsis
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 9;1639 Medical Center Parkway;Suite 400;Murfreesboro TN 37129
 
ZIP Code
37129
 
Solicitation Number
36C24919B0010
 
Response Due
4/15/2019
 
Point of Contact
COREY.MALIK@VA.GOV
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Page 5 of 5 THIS IS A PRESOLICITATION NOTICE The Department of Veterans Affairs, Nashville VA Medical Center is preparing to issue an Invitation for Bid (IFB) for Project 626-18-601 Provide Emergency Power to Telecommunication Rooms SET ASIDE: 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) PROJECT MAGNITUDE: Between $1,000,000.00 and $2,000,000.00 NAICS: 236220 Commercial and Institutional Building Construction SMALL BUSINESS SIZE STANDARD: $36.5 million PROJECT OVERVIEW: This project will provide construction services for the the upgrading of the electrical service to the closets from 120V normal power to 208V emergency power to accommodate the Cisco Systems Catalyst 4500 Series Switches operating at their maximum power configuration. The affected closets are: Building 1, Room D-002b Building 1, Room B-016a. Building 1, Room D-102 Building 1, Room C-132c Buildign 1, Room B-237 Building 1, Room C-219 Building 1, Room B-328 Building 1 Room C-306e (Deduct Alternate #3) Building 1, Room B-435a (Deduct Altnerate #1) Building 1, Room A-933 Building 3/4, Room 3201 (Deduct Alternate #2) Building 5, Room 5104 Building 6, Room 6101 Building 8, Room 8101 (Boiler Room) Building 12, Room 12002 Most of the closets are interior rooms without an adjacent exterior building wall. The size of the cooling units will take into consideration the heat loads of the new Cisco Systems Catalyst 4500 Series Switches. Statement of Work The scope includes upgrade of the electrical service from 120V normal power to 208V emergency power for the new Cisco Systems Catalyst 4500 Series switches operating at maximum power configuration. Cooling systems for the affected closets will also be revised, and electrical circuits for the revised cooling system will be included. The proposed scenario for serving the TIP units and closets is to circuit power from existing panels which were added in prior construction and add additional panels if those are needed. Emergency power is to be provided via a 30A 208V twist lock receptacle intended for a UPS in each TIP room, as well as Normal power distributed via two (2) 208V 20A twist lock receptacles for the normal power feed to the new switches. The normal feeder power will be distributed from an existing normal panelboard located in the basement electrical room of Building 1. Where TIP rooms are located in buildings other than Building 1, power will be served from adjacent panels which exist in the buildings being served. One UPS will be provided and turned over to the VA OIT, for each TIP room, with the following characteristics: NEMA L6-30P input; 8 NEMA 5-15/20R, 2 L6-20R & 1 L6-30R outlets, Rack mounted, 5kVA / 5000VA line interactive UPS; Sine wave output, 208 & 120V output during brownouts to 167 and over voltages to 260V, 3750W. The delivery of the UPS will be coordinated with the COR and the OIT. The solicitation is anticipated to be posted to the Federal Business Opportunities (FedBizOpps) website www.fbo.gov on or about April 15, 2019. Important Notice: Prior to submitting a proposal under this SDVOSB set- aside solicitation, bidders/offerors must have an active registration, being both listed and viewable in the database located at the Center for Verification & Evaluation (CVE) (www.vip.vetbiz.gov) in accordance with 38 CFR Part 74 and VAAR 819.70. Other required registrations that will be verified upon offer submission are: System for Award Management (SAM): https://www.sam.gov/portal/public/SAM/ VETS 4212 Report must be completed: http://www.dol.gov/vets/vets4212.htm NO TELEPHONE CALLS OR QUESTIONS WILL BE CONSIDERED UNTIL THE FORMAL SOLICITATION IS RELEASED. NOTE: THIS NOTICE MAY HAVE POSTED ON FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (27-MAR-2019). IT ACTUALLY APPEARED OR REAPPEARED ON THE FEDBIZOPPS SYSTEM ON 15-JUL-2019, BUT REAPPEARED IN THE FTP FEED FOR THIS POSTING DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/NaVAMC/VAMCCO80220/36C24919B0010/listing.html)
 
Place of Performance
Address: ROBLEY REX VA MEDICAL CENTER;800 ZORN AVENUE;LOUISVILLE, KENTUCKY
Zip Code: 40206
Country: USA
 
Record
SN05369596-F 20190717/190715230013 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.