Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 17, 2019 FBO #6445
MODIFICATION

Z -- Repair Building 3004, Schofield Barracks, Hawaii

Notice Date
7/15/2019
 
Notice Type
Modification
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Attn: CECT-POH Building 230 Fort Shafter HI 96858-5540
 
ZIP Code
96858-5540
 
Solicitation Number
W9128A19B0002
 
Point of Contact
Colin Waki, Contract Specialist, Phone 808-835-4393, - Kent Tamai, Contracting Officer, Phone 808-835-4377, Fax 808-835-4396
 
E-Mail Address
colin.k.waki@usace.army.mil, kent.a.tamai@usace.army.mil
 
Small Business Set-Aside
N/A
 
Description
This announcement constitutes a Pre-Solicitation notice (synopsis) in accordance with FAR Subpart 5.2. The U.S. Army Corps of Engineers, Honolulu District hereby announces its intent to issue a solicitation entitled, "Repair Building 3004, Schofield Barracks, Hawaii," as described within this announcement. The Government intends to issue a formal solicitation via an Invitation for Bid (IFB) in accordance with FAR Part 14, which will follow this announcement and will take place no sooner than 15 days from the publication of this announcement. Solicitation plans and specifications will be made available for viewing and/or downloading on the Federal Business Opportunities (FedBizOpps) website located at https://www.fbo.gov/ on or after May 31, 2019. The Government intends to solicit this requirement as an unrestricted procurement. The North American Industry Classification Code (NAICS) for this requirement is 236220 (Commercial and Institutional Building Construction). The small business size standard for this NAICS code is $36,500,000 average annual revenue. The Government intends to award a firm-fixed price contract as a result of this solicitation. Project Description: This is a design-bid-build requirement to repair or replace deteriorated and failing building components. First floor includes repair of existing interior walls, repair of failing Heating Ventilation and Air Conditioning system, lighting, electrical wiring and conduits, communication, fire alarm, plumbing to support two Company Headquarters. Existing first floor to be repaired to accommodate two (2) Company Operations Facilities (COFs). Two arms vaults will be repaired on the first floor. Second and third floors repairs will include repairing failing window unit air conditioning, lighting, electrical, communication, fire alarm, plumbing, and roofing. Structural repairs to the entire building include floor framing strengthening to support code prescribed live loads; beams, columns, and foundation strengthening to meet seismic life-safety performance levels. The concrete floor will be repaired and steel beams will be designed to carry the load demand from the existing floor beams, and repair the overall gravity load capacity in the floor repair areas. New floor openings will be made to relocate stair shafts and install a new elevator. Existing failed or failing windows will be repaired with blast rated glazing systems that respect historic aesthetics. Supplemental structural steel framing (vertical mullions, heads, and sills) will be required. Existing aged plumbing fixtures, piping and existing hot water system will be repaired. Existing failed or failing flooring, wall partitions, ceilings, doors and windows will also be repaired. Surfaces will be patched, repaired and repainted. Existing failed and failing air cooled chillers, piping, fan coil units, and other mechanical equipment and appurtenances will be repaired. Incidental lead based paint, asbestos containing material (ACM) and light fixture removal are included. Personnel are not exposed directly to ACM and all safety precautions will be followed. Failed or failing light fixtures, suspended ceilings, electrical power and communication systems will be repaired. Fire protection and mass notification systems/alarms will be repaired or installed to meet current Life Safety Code and base physical security requirements. Failing exterior finishes will require repainting and minor repair to spalled concrete. The estimated period of performance is 24 to 36 months. The project magnitude is $25,000,000 to $50,000,000. An organized site visit will be conducted at a date and time that is to be determined. It is the bidder's responsibility to check for any posted changes to the solicitation. Solicitation documents will not be issued on compact disc (CD) unless the Government determines that it is necessary. Bidders must have and/or maintain an active registration with the System for Award Management (SAM) website to be eligible for a Government contract award. To register in SAM, go to https://www.sam.gov. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (15-JUL-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/USA/COE/DACA83/W9128A19B0002/listing.html)
 
Place of Performance
Address: Building 3004 Schofield Barracks, HI
Zip Code: 96857
Country: US
 
Record
SN05370641-F 20190717/190715230101 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.