SOLICITATION NOTICE
65 -- 589-19-3-7626-0142, EK, CT DOSE PROFILER
- Notice Date
- 7/19/2019
- Notice Type
- Synopsis
- NAICS
- 334515
— Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office (NCO) 15;3450 S 4th Street Trafficway;Leavenworth KS 66048
- ZIP Code
- 66048
- Solicitation Number
- 36C25519Q0636
- Response Due
- 7/26/2019
- Archive Date
- 9/24/2019
- Point of Contact
- 913-946-1168
- Small Business Set-Aside
- N/A
- Description
- Statement of Work: EKHCS, HTM Department The HTM Department desires to replace its obsolete Fluke TNT 12000 Diagnostic X-ray QA system (589-EE138200) with Name Brand or Equal to the BLACK PIRANHA Model 557. This system can be used to test radiation-producing equipment and other radiological modalities for compliance within certain predetermined, accepted metrics and determine both safety and efficacy of using these devices on patients. This replacement system shall be upgradable to meet anticipated technology advancements over the next seven years. The system can be used to keep the facility in compliance with requirements outlined in Joint Commission (JC) Environment of Care (EC) 02.04.03 Elements of Performance (EP) 21, 22, 23, 24 and 34. The system shall be: Name Brand or Equal to the BLACK PIRANHA Model 557 Transmitting all invasive and non-invasive test data (mA, mAs, kVp, Time, and Dose) via Bluetooth wireless Vendor shall produce Federal Information Processing Standards (FIPS) 140-2 certificate number, is certified Ability to check the detector position Solid state detector Base unit (BP) includes ability to measure all basic parameters. Probes shall operate on battery for at least 12 hours continuous operation on a full charge. Being calibrated a minimum of every two (2) years Calibration must be meet all NIST standards. Downloading data in an MS Excel spreadsheet format both in real time and as a completed QA report. Alternatively, the system should be able to save test data directly into a Word or Excel file and transfer completed chart to a remote document. Retaining 15-hour battery life Testing RF, CT, and Dental Modalities Vendor must provide training to two individuals on-site. Vendor should provide at a minimum a two year manufactures warranty and have an option to purchase an extended warranty. Any software required to display or manipulate data must be included. Software should function in a Windows 7 or 10 Operating System (OS). NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (19-JUL-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/spg/VA/LeVAMC/VAMCKS/36C25519Q0636/listing.html)
- Record
- SN05375602-F 20190721/190719230016 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |