Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 08, 2019 FBO #6467
SOURCES SOUGHT

D -- Ophthalmic Instruments Eye Clinic

Notice Date
8/6/2019
 
Notice Type
Synopsis
 
NAICS
339115 — Ophthalmic Goods Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 22;4811 Airport Plaza Drive;Suite 600;Long Beach CA 90815
 
ZIP Code
90815
 
Solicitation Number
36C26219Q1131
 
Response Due
8/12/2019
 
Archive Date
8/27/2019
 
Point of Contact
562-766-2244
 
Small Business Set-Aside
N/A
 
Description
Page 3 of 3 THIS REQUEST FOR INFORMATION (RFI) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT DESCRIPTION This is NOT a solicitation announcement. This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339115 (size standard of 1000 employees). Responses to this sources-sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources-sought, a solicitation announcement may be published. Responses to this sources-sought synopsis are not considered adequate responses for a solicitation announcement. The Department of Veterans Affairs (VA), VISN 22 Network Contracting Office, is seeking sources that can provide Ophthalmic Equipment, brand name or equal, that can meet the following salient characteristics: ----------------------- --------------------- ------------------------------- ITEM NO. DESCRIPTION QUANTITY UNIT OR STOCK NO. ----------------------------------------------------------------------------- EQUIPMENT: CSRE980 CHAIR, EXAM.. RELIANCE 980 FULL AUTO RECLINE (LOW BASE) -LAYS FLAT, LOW AND SPECIAL HEADREST 22 EA Exam Chair and Head Rest Must be able to go completely flat Must be able to accommodate up to 600 lbs. Must have locking arm rests Must have round base CSRE940 SYSTEM, GLIDE, RELIANCE 940 WHEELCHAIR ACCESSIBLE. 20 EA Wheelchair with accessible glide system Must be ADA compliant Must have locking system CSRE7900ICWC STAND, INSTRUMENT, RELIANCE 7900, W/CONSOLE, OVER HEAD LAMP & REFRACTOR ARM & WHEELCHAIR ACCESSIBLE 20 EA 7900 Instrument Stand w/console Must have overhead lamp Must have refractor arms Must be wheelchair accessible Must be compatible with exam chair STRE5346 STOOL, RELIANCE 5346, W/ROUND SEAT, BACKREST & RING ELEVATION. 20 EA 5346 Stool Must have ring elevation (no lever) Must have backrest CSRE2000 CHAIR, LASER, RELIANCE 2000 2 EA 2000 Laser Chair Must swivel 360 degrees Must come with foot switch that raises and lowers chair Must have hand rails and foot rests REAO11636 REICHERT ILLUMINATED PHOROPTOR-CYL 15 EA Reichert Illuminated Phoroptor Must be illuminated Must come in black color RETOEXAM5000 SYSTEM, REFRACTION, TOPCON CV5000S, ON DESK COMPLETE 5 EA Topcon CV5000S refraction desk Must be compatible with Top Con auto refractor and acuity system. CPMS2020BASICC SYSTEM, M&S SMART, 20/20 STANDARD COMPUTERIZED VISUAL ACUITY SYSTEM ( MUST INCLUDE: ETDRS, CONTRAST SENSITIVITY, GLARE TESTING OPTION) 27 EA M&S Smart System Must have ETDRS Chart Must have contrast sensitivity. Must have glare testing option. Must be compatible with auto refraction system. LMMA4004 LENSMETER, MARCO 101 MANUAL 8 EA MARCO 101 Lensmeter Must have full 90-degree inclination Must be LED SLHS0900-00111LE LAMP, HAAG STREIT BQ LED SLIT (UNIT MODEL) 20 EA Haag Streit BQ Led Slit lamp (Unit Model) Must sit on instrument stand. Must be LED Must have five magnifications Must have 14 mm slit length TOHS09004-4 TONOMETER, HAAG STREIT BQ APPLANATION (ALSO FOR BX, BP SLIT LAMP) 21 EA Haag Streit BQ Applanation Tonometer Must fit with Haag Streit BQ Slit Lamp (Unit Model). SLHS09007-10 30 SPLITTER, BEAM, FOR HAAG STREIT SLIT LAMP 5 EA Beam Splitter for Haag-Streit Slit Lamp Must fit with Haag Streit BQ Slit Lamp (Unit Model). SLHS09007-13 TUBE, OBSERVER, W/EYEPIECE FOR HAAG-STREIT SLIT LAMP 5 EA Observer Tube w/eyepiece for Haag-Streit Silt Lamp Must fit with Haag Streit BQ Streit Slit Lamp SLHS0900-00100LE LAMP, SLIT, TABLE MODEL, HAAG STREIT BQ LED 1 EA Haag Streit BQ Led Slit Lamp Table Model Must sit on instrument stand. Must be LED Must have five magnifications Must have 14 mm slit length SLHS7220550SEETP MODULE, IMAGING, HAAG STREIT IM900, W/EYESUITE SOFTWARE & RM02 RELEASE MODULE FOR EXISTING BQ LED SLIT LAMP W/CPU 1 EA Haag Streit IM900 Imaging Module w/eyesuite software and RM02 Release Module Must be compatible with BQ 900 BIKE1205P10200 KEELER WIRELESS VANTAGE PLUS SLIMLINE LED W/ CHARGER & BATTERY 21 EA Keeler Wireless Vantage Plus LED W/charger & Battery Must be wireless Must hold charge for 4 6 hours of continuous use. Must have IR/UV filters. TOAO230650 REICHERT TONOPEN AVIA 20 EA Reichert Tonopen Avia Must have auto calibration Must be portable Prefer quick tap measurement mode XZAC245100 18 PEN, ACCUTOME PACH 12 EA Accutome Pach Pen Must have 2.5 mm probe or less Must have lithium battery Must have +- five microns accuracy LMTOCL300P 19 LENSOMETER, TOPCON CL300P AUTO, W/PRINTER 4 EA Topcon CL 300 P Must be compatible with refraction system Must give UV readings Must have progressive mode ARTOKR1 20 REFACTOR/KERATOMETER, TOPCON KR-1 FULL AUTOMATIC AUTO. 1 EA Topcon KR-1 full automatic auto refractor/keratometer Must be compatible with refraction system Must give keratometry readings. Must have cataract mode ARTOKR800S 21 REF/KERATOMETER, TOPCON AUTO, W/ SUBJECTIVE VA MEASUREMENT, CONTRAST & GLARE TESTING 3 EA Topcon Auto Ref/Keratometer w/subjective VA measurement Must have glare testing and subjective VA Must be compatible with refraction system ARNIKPLUS3 22 RETINOMAX K-PLUS 3 (88449) 3 EA Retinomax K-Plus 3 Must be portable Must give keratometry readings Must come with battery pack and charging base Must not weigh more than 2 kilograms TA250W 23 TABLE, WHEELCHAIR 4 EA Wheelchair Table Must be ADA compliant Must be no greater than 26 x 36 Must be automatic lift SLCCBA904C 24 LAMP, SLIT, HAAG STREIT HAND HELD (5606013) W/POWER CENTER, 2X RECHARGEABLE ENERGY PACK & SMALL CASE. 4 EA Haag Streit Hand Held slit lamp (5606013) w/Power Center Must come in case Must include two energy packs, charger, power supply Required services: Service and support Calibration verification of goldman tonometers and acuity systems 1-year warranty Office call within 1 year of the delivery date Part Loaner Service/training on all equipment Installation and calibration Onsite consultation Remote assistance The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies that fulfill the required specifications. If you are interested and capable of providing the sought-out supplies, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc. (2) Is your company considered small under the NAICS code identified under this RFI? (3) Are you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items? (4) If you re a small business and you are an authorized distributor/reseller for the items identified above (or equivalent product/solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? (5) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number. (6) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract? (7) Please provide general pricing for your products/solutions for market research purposes. (8) Please submit your capabilities in regard to the salient characteristics being provided and any information pertaining to equal to items to establish capabilities for planning purposes? *** Submissions addressing Section (8) should show clear, compelling and convincing*** evidence that all equal to items" meet all required salient characteristics. Responses to this notice shall be submitted via email to edgar.alvizar@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Monday, August 12, 2019 at 9:00 a.m. PST. If a solicitation is issued it shall be announced later, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (06-AUG-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/LBVANBC/VAMD/36C26219Q1131/listing.html)
 
Place of Performance
Address: Department of Veterans Affairs;VA Loma Linda Healthcare System
Zip Code: 90073
Country: USA
 
Record
SN05393929-F 20190808/190806230021 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.