SOURCES SOUGHT
65 -- Connex Spot Monitors
- Notice Date
- 8/14/2019
- Notice Type
- Synopsis
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 4
- ZIP Code
- 17042
- Solicitation Number
- 36C24419Q1043
- Response Due
- 8/20/2019
- Archive Date
- 11/18/2019
- Point of Contact
- Michael.Shull@va.gov
- Small Business Set-Aside
- N/A
- Description
- This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government. This notice is intended strictly for market research. The purpose of this Sources Sought Notice is to determine interest and capability of potential vendors to provide Welch Allyn Connex Spot Monitors along with the device connectivity licensing. Welch Allyn Connex Spot Monitors able to connect to the Connex centralized server. Additionally, it must have a bi-directional interface with the computerized patient record system (CPRS) that serves at the VA Pittsburgh electronical health record (EHR). VA Pittsburgh will make a best value decision. The unit must function of the wireless infrastructure and follow cybersecurity requirements. Minimum requirements for Welch Allyn Connex Spot Monitor are: The integration must contain a method for a centralized repository. This means that it takes information from the multiple Vital Sign Monitors and then passes on this information to CPRS for all parameters. The Integration must contain a method for BCMA use at the point of care. This means that the user must be able to scan a patient wrist band or Veterans Identification Card to associate data collected with the patient s record. Additionally, the system must have ability to use the staff DUZ number assigned inside VistA for staff identification. The information must meet HL7 message formatting and VistA integration based on existing CPRS standards. This must be true for inbound and outbound traffic. The integration to CPRS must be seamless. A seamless integration means that any validation of information going into the patient record must be achievable from the point of care. The integration must be wireless capable using new and existing VA Pittsburgh infrastructure and must comply with Federal Information Processing Standard (FIPS) 140-2. Installation and integration must also be provided. NIBP Systolic pressure from 30-260 mmHg NIBP Diastolic pressure from 20-220 mmHg MAP from 20-230 mmHg Pulse from 20-250 bpm Autodeflate pressure of 300+/- 15 Provides cuffs of small adult, adult, large adult, and thigh Tempanic temperature probe Approximately 15 seconds on measurement time 2-dimensional barcode scanner Must display Systolic pressure, Diastolic, MPA, Pulse, SpO2, temperature Can monitor height, weight, BMI, pain level, respiration rate Must provide 2D Barcode Scan capabilities for CPRS interface and recognition. Battery must be able to sustain constant use for at least 5 hours and hold a charge for at least 5 days. Must allow for continuous monitoring for all parameters. Must be within (HxWxD) 10 x 12 x 7 in Must weight no more than 10 lbs **NOTE** Please read all of this document before submitting questions, or an affirmative response. All interested parties shall respond, via email, with the following information: Company Name Address Phone Number Point of Contact Any Current Available Contracts/Schedules: Socio-Economic classification Status (HubZone, Service Disabled Veteran-Owned, etc.) A brief description of your interest and experience providing the items described above. PLEASE USE THIS LANGAUGE IN THE SUBJECT LINE OF YOUR E-MAIL RESPONSE (36C24419Q1043 Connex Spot Monitors) Responses are due by 12:00 PM Eastern on 08/20/2019 via email to Michael.Shull@va.gov ADDITIONAL INFORMATION: The Government will neither award a contract solely on the basis of this notice nor will it reimburse the contractor for any costs associated with preparing or submitting a response to this notice. This notice does not constitute a Request for Quotation (RFQ), Request for Proposal (RFP) or an Invitation for Bid (IFB), nor does this issuance restrict the Government's acquisition approach. The Government reserves the right to reject in whole or part any industry input as a result of this announcement. The Government recognizes that proprietary data may be a part of this effort. If so, clearly mark such restricted or proprietary data and present it as an addendum to the non-restricted/non-proprietary information. If the Government decides to award a contract for this or related effort, a solicitation will be published and posted on the GSA eBuy or FBO.gov website. Interested parties are responsible for monitoring the GSA eBuy website and FBO.gov and downloading a copy of the solicitation. End of Document NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (14-AUG-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/spg/VA/PiVAMC646/PiVAMC646/36C24419Q1043/listing.html)
- Record
- SN05404579-F 20190816/190814230026 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |