Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 01, 2019 FBO #6491
SOLICITATION NOTICE

65 -- Supply: MRI Non-magnetic Monitors

Notice Date
8/30/2019
 
Notice Type
Combine Synopsis/Solicitation
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 8 (NCO 8);8875 Hidden River Pkwy Suite 525;Tampa FL 33637
 
ZIP Code
33637
 
Solicitation Number
36C24819Q1412
 
Response Due
9/5/2019
 
Archive Date
10/20/2019
 
Point of Contact
leslie.hawkins2@va.gov
 
Small Business Set-Aside
Total Small Business
 
Description
36C24819Q1412 Page 2 of 2 This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6 Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice.   This announcement constitutes the only solicitation; quotations are being requested and a written solicitation will not be issued.  Solicitation number 36C24819Q1412 is issued as a Request for Quotation (RFQ).   The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC Number: 2019-05, Effective Date: August 13, 2019.   This requirement is a total small business set-aside. The associated North American Industry Classification System (NAICS) Code for this acquisition is 334510, with a small business size standard of 1250 employees. All interested companies shall provide quotations using the below Price/Cost Schedule format for the following brand name or equal items. PRICE/COST SCHEDULE ITEM INFORMATION ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 2.00 EA __________________ __________________ 3880 MRI Standard Monitor, +Temp, ECG, SP02, NIB, ETC02 & Temp Manufacturer: IRADIMED Corporation PRODUCT NUMBER: 3880-4 (BRAND NAME OR EQUAL) Refer to Statement of Need for salient characteristics and additional information. 0002 2.00 EA __________________ __________________ MRI Monitor, Remote System, with REmote Tablet, Base and Recorder Manufacturer: IRADIMED Corporation PRODUCT NUMBER: 3885 (BRAND NAME OR EQUAL) 0003 2.00 EA __________________ __________________ Pole Mount, Rotating 3880 Monitor Manufacturer: IRADIMED Corporation PRODUCT NUMBER: 1891 (BRAND NAME OR EQUAL) 0004 1.00 EA __________________ __________________ MRI Wireless Multigas Unit W/02 Manufacturer: IRADIMED Corporation PRODUCT NUMBER: 3886 (BRAND NAME OR EQUAL) 0005 1.00 EA __________________ __________________ Mount, Arm, 3880 Monitor Manufacturer: IRADIMED Corporation PRODUCT NUMBER: 1884 (BRAND NAME OR EQUAL) 0006 1.00 EA __________________ __________________ Mount, Arm, 3886 Agents Module Manufacturer: IRADIMED Corporation PRODUCT NUMBER: 1883 (BRAND NAME OR EQUAL) 0007 1.00 EA __________________ __________________ Dual Radio Module, 2.4GHz, 3880/3886 Manufacturer: IRADIMED Corporation PRODUCT NUMBER: 1887 (BRAND NAME OR EQUAL) 0008 2.00 EA __________________ __________________ Roll Stand, Non-Magnetic, 3880 Monitor Manufacturer: IRADIMED Corporation PRODUCT NUMBER: 1119M (BRAND NAME OR EQUAL) GRAND TOTAL __________________ DELIVERY SCHEDULE ITEM NUMBER QUANTITY DELIVERY DATE 0001-0008 SHIP TO: JAMES A. HALEY VA HOSPITAL 13000 BRUCE B. DOWNS TAMPA, FL 33612 USA ALL 30 days ARO ALL ITEMS SHALL BE DELIVERED AND INSTALLED WITHIN 30 DAYS AFTER RECEIPT OF ORDER AND ORDER PLACEMENT. STATEMENT OF NEED MRI Non-Magnetic Monitor System GENERAL: The James A. Haley Veterans Hospital, Anesthesiology Department, 13000 Bruce B. Downs Blvd, Tampa, Florida 33612, has a requirement for a monitor system that is safe for use in the MRI Suite. BACKGROUND: Anesthesiology Department is responsible for anesthetizing patients who cannot undergo MRI procedures without sedation. Many of our veteran-patients suffer from PTSD and other illnesses that make it difficult or impossible to undergo an MRI scan. Additionally, anesthesiology provides care for critically ill patient populations undergoing MRI scans. PURPOSE: The James A. Haley, Anesthesiology Department does not currently own any Magnetic Resonance (MR) safe monitors and therefore, unable to provide general anesthesia for MRI patients. SCOPE: James A Haley is requesting contractors provide brand name or equal equipment that meets or exceed the physical, functional and performance of the listed salient characteristics as follows in this section. The equipment features are essential to the technical requirements to meet the needs of the service. PHYSICAL CHARACTERISTICS: Equipment must have the physical characteristics to enable the government to perform the capabilities: The monitor must be non-magnetic. MR uses a superconducting magnet that can cause ferromagnetic objects to become projectiles. The monitor must be wireless. Conventional wired products cannot be used in the MRI suite. The monitor must be visible from the control room in-order-to safely use a general anesthesia machine. Remote capability via tablet technology is highly desirable. The clinician must be able to fully operate the monitor from the MRI control room. e. The monitor must have high-quality pulse oximetry. Masimo technology is preferable. Color TFT resistive touchscreen Monitor must be lightweight (ideally less than 10 pounds) and easy to place on patient stretcher. Must be able to mount to an IV pole. FUNCTIONAL AND PERFORMANCE CHARACTERISTICS: Equipment must provide the following function and performance capabilities to enable the government to perform the capabilities and obtain required results for patient care: Magnetic Field Limit: 30,000 Gauss: 0.5 to 3.0 Tesla MRI Systems. The monitor must have ECG with dynamic gradient filtering. The EKG reading must be free from MR inference that causes EKG distortion. Must have a rechargeable battery with a battery life indicator in order to transport patients to recovery area. SpO2 averaging time:6 seconds. Pulse Rate Accuracy: ± 3 ppm Heart Rate (HR) Averaging Method: Five point Mean filter Thermal line recorder: Single or Dual Waveform Lead Set Configuration: 3 and 5 lead: I, II, III, V, AVF, AVR, AVL Invasive blood pressure capability: 1, or 2 simultaneous pressure channels Temperature monitoring: direct fiberoptic. PERFORMANCE MONITORING: Contractor shall provide appropriate training on utilization of equipment. Contractors submitting quotation for brand name equal product shall submit with quote for evaluation the brand name equal specifications used to determine product compliance with physical, functional, and performance salient characteristics outlined in solicitation and Statement of Need. Products will be safely and securely stored when not in use. PLACE OF PERFORMANCE: James A. Haley Veterans Hospital, 13000 Bruce B. Downs Blvd, Tampa, FL 33612. DELIVERY SCHEDULE: All items to be delivered and installed within 30 days of purchase order processing and order placement. FOB: DESTINATION pricing. WARRANTY OF EQUIPMENT: Contractor must provide manufacturer s warranty on all provided equipment. Gray market items are Original Equipment Manufacturers (OEM) goods sold through unauthorized channels in direct competition with authorized distributors. This procurement is for new OEM medical supplies, medical equipment and/or services contracts for maintenance of medical equipment (i.e. replacement parts) for VA Medical Centers. No remanufactures or gray market items will be acceptable. Vendor shall be an OEM, authorized dealer, authorized distributor or authorized reseller for the proposed medical supplies, medical equipment and/or services contracts for maintenance of medical equipment (i.e. replacement parts), verified by an authorization letter or other documents from the OEM, such that the OEM s warranty and service are provided and maintained by the OEM. All software licensing, warranty and service associated with the medical supplies, medical equipment and/or services contracts for maintenance of medical equipment shall be in accordance with the OEM terms and conditions. The delivery of gray market items to the VA in the fulfillment of an order/award constitutes a breach of contract. Accordingly, the VA reserves the right enforce any of its contractual remedies. This includes termination of the contract or, solely at the VA s election, allowing the Vendor to replace, at no cost to the Government, any remanufactured or gray market item(s) delivered to a VA medical facility upon discovery of such items. The clause at 52.212-4, Contract Terms and Conditions -- Commercial Items, applies to this acquisition and no additional addenda to the clause included. The clause at 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders -- Commercial Items, applies to this acquisition. 52.204 10 52.209-6 52.219-27 52.222-19 52.222.21 52.222 26 52.222-36 52.222-40 52.222-50 52.223-18 52.225-13 52.232-33 The clause at 52.219-6 NOTICE OF TOTAL SMALL BUSINESS SET-ASIDE (NOV 2011) The clause at VAAR 852.219-10 VA NOTICE OF TOTAL SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS SET-ASIDE (JUL 2016) (DEVIATION) The clause at VAAR 852.219-11 VA NOTICE OF TOTAL VETERAN-OWNED SMALL BUSINESS SET-ASIDE (JUL 2016) (DEVIATION) The clause at VAAR 852.232-72 ELECTRONIC SUBMISSION OF PAYMENT REQUESTS (NOV 2018) The clause at VAAR 852.237-70 CONTRACTOR RESPONSIBILITIES (APR 1984) The clause at VAAR 852.246-71 REJECTED GOODS (OCT 2018) The clause at VAAR 852.273-70 LATE OFFERS (JAN 2003) The following Provisions applies to this acquisition: The provision at 52.204-7, SYSTEM FOR AWARD MANAGEMENT (OCT 2016) The provision at 52.211-6, BRAND NAME OR EQUAL The provision at 52.212-1, INSTRUCTIONS TO OFFERORS COMMERCIAL ITEMS. The provision at 52.212-2 EVALUATION COMMERCIAL ITEMS (OCT 2014) Award shall be made to the quoter whose quotaton offers the best value to the Government. The government will evaluate information based on the following evaluation criteria in accordance with FAR 13.106-2(b)(3): COMPARATIVE EVALUATION The Government will award a Firm-Fixed Price contract to the responsible quoter using a comparative evaluation. The comparative evaluation will be performed in accordance with FAR 13.106-2(b)(3). The government reserves the right to select a quotation that provides benefit to the government that exceeds the minimum but is not required to do so. Quoters are advised that quotation may exceed the requirements, but the government is not requesting or accepting alternate quotes; each response must respond to the solicitation requirement, stated in the RFQ. The government will apply the following comparative evaluation process as the basis for award: Assess the direct comparison of one quote with another in a uniform and fair manner to determine which quote provides the government what it needs, where and when in accordance with the Statement of Need (SON) and this Request for Quote. It is an assessment of which response is best as a whole. Once one quotation is found acceptable, it is compared side-by-side to the remaining ones, and the best one is chosen for the best value to the government. The following comparative evaluation factors shall be used: - Technical: Each offeror s quote shall be evaluated based on equipment and services specifications, to determine if the offeror provides a sound, compliant approach that meets the requirements of the Statement of Need and demonstrates a thorough knowledge and understanding of those requirements and their associated risk. In addition, the offeror must submit for evaluation (1) evidence of warranties, (2) specification of brand name or equal products as detailed in the Price/Cost Schedule and Statement of Need. Delivery Date: The purpose of the delivery factor is to assess the offeror s shipment information and after receipt of order (ARO) delivery days to meet the Government s delivery timeframe of 30 days ARO. - Past Performance: The Government may rely on internal documentation including the Contract Performance Assessment Reporting System (CPARS) and contracting officer s knowledge of and previous experience with supply or service being acquired for determining Past Performance. If no record of past performance is found in CPARS, the contract shall not receive a favorable or unfavorable rating but shall receive a rating of neutral. - Price: Award will be made to the offeror whose price represents the best overall value. Complete Price/Cost schedule. Information not contained in a vendor s quote will not be considered during the evaluation. The Government intends to make award selection without clarification but may determine after evaluating submitted quotes that the elements stated in FAR 13.106-2(b)(3) for evaluation procedures are necessary and conduct them as appropriate. The Government reserves the right to make no award if no quotes meet the requirements of this solicitation. The provision at 52.212-3 OFFEROR REPRESENTATIONS AND CERTIFICATIONS-COMMERCIAL ITEMS. All vendors must have an active registration in the System for Award Management (SAM) portal: https://www.sam.gov prior to award. All quoters certified as a Service-Disabled Veteran-Owned Small Business (SDVOSB) and Veteran-Owned Small Business (VOSB) must be verified as SDVOSB/VOSB in the VetBiz/VIP portal: https://www.vip.vetbiz.gov/ prior to award. End of Provisions All quotes shall be submitted to Raimundo Rivera at raimundo.rivera@va.gov and Leslie Hawkins at leslie.hawkins2@va.gov by 2:00pm EST on September 5, 2019. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (30-AUG-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/TaVAMC673/TaVAMC673/36C24819Q1412/listing.html)
 
Place of Performance
Address: Department of Veterans' Affairs;James A. Haley VA Hospital;13000 Bruce B. Downs Blvd;Tampa, FL
Zip Code: 33612
Country: USA
 
Record
SN05426415-F 20190901/190830230030 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.