SOURCES SOUGHT
66 -- Signal and Sprectrum Analyzer
- Notice Date
- 9/3/2019
- Notice Type
- Sources Sought
- NAICS
- 334515
— Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
- Contracting Office
- Department of the Navy, Naval Air Systems Command, Naval Air Warfare Center Aircraft Division Pax River, Building 441, 21983 Bundy Road Unit 7, Patuxent River, Maryland, 20670, United States
- ZIP Code
- 20670
- Solicitation Number
- 1300802323
- Archive Date
- 10/3/2019
- Point of Contact
- Linda S Loving, Phone: 301-995-4038, Monique, Johnson-Coates, Phone: 301-757-1965
- E-Mail Address
-
linda.loving@navy.mil, monique.johnson@navy.mil
(linda.loving@navy.mil, monique.johnson@navy.mil)
- Small Business Set-Aside
- N/A
- Description
- This is a Sources Sought to procure Calibration Standards (CALSTDs) and ancillary equipment for Aviation Fleet Intermediate Calibration Activities, fleet training activities, and Aviation Navy Calibration Laboratories (NCLs) to support Aviation Organizational and Intermediate level maintenance assets. The Naval Air Warfare Center Aircraft Division (NAWCAD) intends to award a Firm-Fixed Price (FFP) contract, on a sole source basis, to Rohde & Schwarz USA, Inc., 6821 Benjamin Franklin Drive, Columbia, MD, 21046, for this procurement. The statutory authority permitting other than Full and Open Competition is USC 2304(c)(1), as implemented by FAR 6.302-1 only one responsible source and no other supplies or services will satisfy agency requirements. The procedures of FAR Part 12 and 13.5 will be utilized for this commercial acquisition. The draft Statement of Work (SOW), Attachment (1), is hereby provided. Tasking: REQUIREMENTS: 1. Mfr. one year warranty with sticker affixed to each unit plus a warranty certificate. 2. Calibration Certificate and calibration sticker (as applicable for each unit) 3. Units shall be serialized. The contractor shall provide the following equipment with no substitutions: 1. P/N FSV40-N OPTB1, B4 SIGNAL AND SPECTRUM ANALYZER: Qty. 42 To include the following: a) Frequency range: a. DC-coupled: 9 kHz to 40 GHz b. AC-coupled: 10 MHz to 40 GHz b) Frequency resolution: 0.01 Hz c) Reference frequency, internal: a. Accuracy: (time since last adjustment × aging rate) + Temperature drift + calibration accuracy b. Aging per year: 1 × 10-7 c. Temperature drift (+5 °C to +45 °C): 1 × 10-7 d) Frequency readout: a. Marker resolution: 1 Hz b. Uncertainty: ±(marker frequency × reference uncertainty + 10 % × resolution bandwidth + ½ (span/(sweep points - 1)) + 1 Hz) c. Number of sweep (trace) points: i. default value: 691 ii. range: 101 to 32001 d. Marker tuning frequency step size: i. marker step size = sweep points: span/(sweep points -1) ii. marker step size = standard: span/(default sweep points -1) e) Frequency counter resolution: 0.001 Hz f) Count accuracy: ±(frequency × reference uncertainty + ½ (last digit)) g) Display range for frequency axis: 0 Hz, 10 Hz to max. frequency h) Resolution: 0.1 Hz i) Max. span deviation: 0.1 % j) Spectral purity: a. SSB phase noise: frequency = 500 MHz, carrier offset i. 100 Hz < -84 dBc (1 Hz) ii. 1 kHz < -101 dBc (1 Hz) iii. 10 kHz < -106 dBc (1 Hz) iv. 100 kHz < -115 dBc (1 Hz) v. 1 MHz < -134 dBc (1 Hz) vi. 10 MHz typ. -150 dBc (1 Hz) b. Residual FM: i. frequency = 500 MHz, RBW = 1 kHz, sweep time = 100 ms < 3 Hz, nominal -160 k) Sweep time: a. Range: i. span = 0 Hz 1 μs to 16000 s ii. span ≥ 10 Hz, swept 1 ms to 16000 s 1 iii. span ≥ 10 Hz, FFT 7 μs to 16000 s 2 b. Sweep time accuracy: i. span = 0 Hz 0.1 %, nominal ii. span ≥ 10 Hz, swept 3 %, nominal l) Resolution bandwidths: a. Sweep filters and FFT filters i. Resolution bandwidths: (-3 dB) span ≥ 10 Hz, sweep filters 1 Hz to 10 MHz in 1/2/3/5 sequence span ≥ 10 Hz, FFT filters 1 Hz to 300 kHz in 1/2/3/5 sequence span = 0 Hz 20 MHz, 28 MHz additionally ii. Bandwidth uncertainty < 3 %, nominal iii. Shape factor 60 dB:3 dB < 5, nominal b. Video bandwidths 1 Hz to 10 MHz in 1/2/3/5 sequence, 20 MHz, 28 MHz c. Signal analysis bandwidth f ≤ 7 GHz 28 MHz, nominal m) Level: a. Display range: displayed noise floor up to +30 dBm b. Max. input level: i. DC voltage: 1. AC-coupled 50 V 2. DC-coupled 0 V ii. CW RF power: 1. RF attenuation 0 dB 2. RF preamplifier = OFF 20 dBm (= 0.1 W) 3. RF attenuation ≥ 10 dB 4. RF preamplifier = OFF 30 dBm (= 1 W) iii. Pulse spectral density: 1. RF attenuation 0 dB: 97 dB μV/MHz 2. RF preamplifier = OFF iv. Max. pulse voltage RF attenuation ≥ 10 dB 150 V v. Max. pulse energy RF attenuation ≥ 10 dB, 10 μs 1 mWs n) Spurious responses: a. Image response: i. 20 MHz ≤ f ≤ 7 GHz: 1. fin - 2 × 8409.9 MHz (1st IF) typ. < -80 dBc 2. fin - 2 × 729.9 MHz (2nd IF) < -80 dBc 3. fin - 2 × 89.9 MHz (3rd IF) < -80 dBc ii. 7 GHz < f < 30 GHz: 1. fin ± 2 × 729.9 MHz (1st IF) < -80 dBc 2. fin - 2 × 89.9 MHz (2nd IF) < -80 dBc iii. 30 GHz < f ≤ 40 GHz: 1. fin ± 2 × 729.9 MHz (1st IF) < -70 dBc 2. fin - 2 × 89.9 MHz (2nd IF) < -80 dBc b. W × H × D 435 mm × 192 mm × 460 mm (17.13 in × 7.56 in × 18.11 in) o) Intermediate frequency response: a. 20 MHz ≤ f ≤ 7 GHz: i. 1st IF (8409.9 MHz) typ. < -70 dBc ii. 2nd IF (729.9 MHz) < -80 dBc iii. 3rd IF (89.9 MHz) < -80 dBc b. 7 GHz < f ≤ 40 GHz: i. 1st IF (729.9 MHz) < -80 dBc ii. 2nd IF (89.9 MHz) < -80 dBc p) Residual spurious response: a. 0 dB RF attenuation: i. f ≤ 1 MHz < -90 dBm ii. f > 1 MHz < -103 dBm q) Local oscillator related spurious: a. f < 15 GHz: i. kHz ≤ offset from carrier ≤ 10 MHz < -70 dBc ii. offset from carrier > 10 MHz < -80 dBc b. 15 GHz ≤ f < 30 GHz: i. 1 kHz ≤ offset from carrier ≤ 10 MHz < -64 dBc ii. offset from carrier > 10 MHz < -74 dBc c. 30 GHz ≤ f ≤ 40 GHz: i. 1 kHz ≤ offset from carrier ≤ 10 MHz < -58 dBc ii. offset from carrier > 10 MHz < -68 dBc r) Other interfering signals: a. Subharmonic of 1st LO: 20 MHz ≤ f < 7 GHz, spurious at 8410 MHz - 2 × fin: < -70 dBc b. Harmonic of 1st LO: mixer level < -25 dBm, Spurious at fin -4205 MHz: < -70 dBc s) Level display: a. Logarithmic level axis: 1 dB to 200 dB, in steps of 1/2/5 b. Linear level axis: 10 % of reference level per level division, 10 divisions or logarithmic scaling c. Number of traces: 6 d. Trace detector: Max Peak, Min Peak, Auto Peak (Normal), Sample, RMS, Average e. Trace functions: Clear/Write, Max Hold, Min Hold, Average, View f. Setting range of reference level: -130 dBm to (-10 dBm + RF attenuation - RF preamplifier gain), in steps of 0.01 dB g. Units of level axis: i. logarithmic level display dBm, dBμV, dBmV, dBμA, dBpW ii. linear level display μV, mV, μA, mA, pW, nW t) Level measurement uncertainty: a. Absolute level uncertainty at 64 MHz: i. RBW = 10 kHz, level -10 dBm, reference level -10 dBm, RF attenuation 10 dB ii. +20 °C to +30 °C: < 0.2 dB (σ = 0.07 dB) iii. 0 °C to +50 °C: < 0.35 dB (σ = 0.12 dB) u) Frequency response referenced to 64 MHz: a. DC coupling, RF attenuation 10 dB, 20 dB, 30 dB, 40 dB, RF preamplifier = OFF, +20 °C to +30 °C i. 9 kHz ≤ f < 10 MHz < 0.5 dB (σ = 0.17 dB) ii. 10 MHz ≤ f < 3.6 GHz < 0.3 dB (σ = 0.1 dB) iii. 3.6 GHz ≤ f < 7 GHz < 0.5 dB (σ = 0.17 dB) iv. 7 GHz ≤ f < 13.6 GHz, span < 1 GHz < 1.5 dB (σ = 0.5 dB) v. 13.6 GHz ≤ f < 30 GHz, span < 1 GHz < 2 dB (σ = 0.66 dB) vi. 30 GHz ≤ f ≤ 40 GHz, span < 1 GHz < 2.5 dB (σ = 0.83 dB) b. Any setting of RF attenuation, RF preamplifier = OFF, 0 °C to +50 °C i. 9 kHz ≤ f < 3.6 GHz < 1 dB (σ = 0.33 dB) ii. 3.6 GHz ≤ f < 7 GHz < 1.5 dB (σ = 0.5 dB) iii. 7 GHz ≤ f < 13.6 GHz < 2.5 dB (σ = 0.83 dB) iv. 13.6 GHz ≤ f < 30 GHz < 3 dB (σ = 1 dB) v. 30 GHz ≤ f ≤ 40 GHz < 3.5 dB (σ = 1.33 dB) c. Any setting of RF attenuation, RF preamplifier = ON, 0 °C to +50 °C: i. 9 kHz ≤ f < 3.6 GHz < 1 dB (σ = 0.33 dB) ii. 3.6 GHz ≤ f < 7 GHz < 1.5 dB (σ = 0.5 dB) d. With R&S®FSV-B29 option, DC coupling, RF preamplifier = OFF, 0 °C to +50 °C: i. 10 Hz ≤ f < 20 Hz < 1.5 dB, nominal ii. 20 Hz ≤ f < 9 kHz < 1 dB (σ = 0.33 dB) v) Attenuator switching uncertainty: a. f = 64 MHz, 0 dB to 70 dB, referenced to 10 dB attenuation: i. < 0.2 dB (σ = 0.07 dB) w) Uncertainty of reference level setting: 0 dB 3 x) Bandwidth switching uncertainty: a. referenced to RBW = 10 kHz: i. sweep filters < 0.1 dB (σ = 0.04 dB) ii. FFT filters < 0.2 dB (σ = 0.07 dB) y) Display nonlinearity: a. Logarithmic level display: i. S/N > 16 dB, 0 dB to -70 dB: 1. < 0.1 dB (σ = 0.04 dB) b. Linear level display: i. S/N > 16 dB, 0 dB to -70 dB 1. 5 % of reference level z) Total measurement uncertainty: a. signal level 0 dB to -70 dB below reference level, S/N > 20 dB, sweep time = AUTO, sweep type = sweep, RF attenuation 10 dB, 20 dB, 30 dB, 40 dB, RF preamplifier = OFF, span/RBW < 100, 95 % confidence level, +20 °C to +30 °C i. 9 kHz ≤ f < 10 MHz 0.39 dB ii. 10 MHz ≤ f < 3.6 GHz 0.28 dB iii. 3.6 GHz ≤ f < 7 GHz 0.39 dB iv. 7 GHz ≤ f < 13.6 GHz 1 dB v. 13.6 GHz ≤ f < 30 GHz 1.32 dB vi. 30 GHz ≤ f ≤ 40 GHz 1.65 dB aa) Trigger: a. Trigger source: free run, video, external, IF power b. Trigger offset: i. span ≥ 10 Hz 31.25 ns to 30 s, min. resolution 31.25 ns (or 1 % of offset) ii. span = 0 Hz: (-sweep time) to 30 s, min. resolution 31.25 ns (or 1 % of offset) c. Max. deviation of trigger offset: ±(7.8125 ns + (0.1 % × trigger offset)) bb) IF power trigger: a. Sensitivity: i. min. signal power: -60 dBm + RF attenuation - RF pre amplifier gain ii. max. signal power -10 dBm + RF attenuation - RF preamplifier gain b. IF power trigger bandwidth: i. RBW > 500 kHz, swept: 40 MHz, nominal ii. RBW > 20 kHz, FFT: 40 MHz, nominal iii. RBW ≤ 500 kHz, swept: 6 MHz, nominal iv. RBW ≤ 20 kHz, FFT: 6 MHz, nominal cc) Gated sweep: a. Gate source: video, external, IF power b. Gate delay 31.25 ns to 30 s, min. resolution 31.25 ns (or 1 % of delay) c. Gate length: 31.25 ns to 30 s, min. resolution 31.25 ns (or 1 % of gate length) d. Max. deviation of gate length ±(7.8125 ns + (0.1 % × gate length)) dd) RF input: a. Impedance: 50 Ω b. Connector: 2.92 mm male (compatible with 3.5mm) c. VSWR: i. RF attenuation ≥ 10 dB 1. 10 MHz ≤ f < 3.6 GHz < 1.5, typ.1.3 2. 3.6 GHz ≤ f < 20 GHz < 2, typ. 1.8 3. 20 GHz ≤ f < 27 GHz < 2.2, typ. 2 ii. 27 GHz ≤ f < 30 GHz 1. DC-coupled < 2.2, typ. 2 2. AC-coupled typ. 2.5 iii. 30 GHz ≤ f ≤ 40 GHz: 1. DC-coupled < 2.5, typ. 2.2 2. AC-coupled typ. 3 iv. RF attenuation < 10 dB, DC-coupled: 1. 10 MHz ≤ f < 7 GHz typ. 2 2. 7 GHz ≤ f < 30 GHz typ. 2.5 3. 30 GHz ≤ f ≤ 40 GHz typ. 3 ee) Setting range of attenuator: a. standard 0 dB to 75 dB, in 5 dB steps b. with R&S®FSV-B25 option 0 dB to 75 dB, in 1 dB steps ff) Setting range of electronic attenuator: a. with R&S®FSV-B25 option, f ≤ 7 GHz 0 dB to 25 dB, in 1 dB steps b. with R&S®FSV-B25 option, f > 7 GHz 0 dB to 9 dB, in 1 dB steps gg) RF preamplifier gain: a. with R&S®FSV-B22 option, f ≤ 7 GHz 20 dB, nominal hh) Probe power supply: a. Supply voltages: +15 V DC, -12.6 V DC and ground, max. 150 mA, nominal ii) Noise source drive: a. Connector BNC female b. Output voltage 0 V/28 V, max. 100 mA, switchable, nominal jj) Power sensor: a. Connector 6-pin LEMOSA female for supported R&S®NRP-Zxx power sensors kk) USB interface: 2 ports, type A plug, version 2.0 ll) Reference output: a. Connector: BNC female b. Impedance: 50 Ω c. Output frequency: d. internal reference 10 MHz e. external reference same as reference input signal f. Level > 0 dBm, nominal mm) Reference input: a. Connector BNC female b. Impedance 50 Ω c. Input frequency range 1 MHz ≤ fin ≤ 20 MHz, in 100 kHz steps d. Required level > 0 dBm into 50 Ω nn) External trigger/gate input: a. Connector BNC female b. Trigger voltage 0.5 V to 3.5 V c. Input impedance 10 kΩ d. IEC/IEEE bus control interface in line with IEC 625-2 (IEEE 488.2) e. Command set SCPI 1997.0 f. Connector 24-pin Amphenol female g. Interface functions SH1, AH1, T6, L4, SR1, RL1, PP1, DC1, DT1, C0 oo) LAN interface: 10/100/1000BaseT: a. Connector: RJ-45 pp) External monitor: a. Connector : VGA-compatible, 15-pin, mini D-Sub qq) Display: 21 cm LC TFT color display (8.4") rr) Resolution: 800 × 600 pixel (SVGA resolution) ss) Pixel: failure rate < 1 × 10-5 tt) Data storage: a. Internal solid state disk ≥ 8 Gbyte b. External supports USB-2.0-compatible memory devices uu) Temperature: a. Operating temperature range 0 °C to +50 °C b. Permissible temperature range 0 °C to +50 °C c. Storage temperature range -40 °C to +70 °C d. Climatic loading +40 °C at 90 % rel. humidity, in line with EN 60068-2-30 vv) Mechanical resistance: a. Vibration: i. Sinusoidal 5 Hz to 150 Hz, max. 2 g at 55 Hz; 0.5 g from 55 Hz to 150 Hz; in line with EN 60068-2-6 ii. random 10 Hz to 300 Hz, acceleration 1.2 g (RMS), in line with EN 60068-2-64 b. Shock: 40 g shock spectrum, in line with MIL-PRF-28800F, class 3 ww) EMC: in line with EMC Directive 2004/108/EC including: i. IEC/EN 61326-1 4, 5 ii. IEC/EN 61326-2-1 iii. CISPR 11/EN 55011 4 iv. IEC/EN 61000-3-2 v. IEC/EN 61000-3-3 xx) Power supply: a. AC supply: 100 V to 240 V, 3 A to 1.25 A; 50 Hz to 400 Hz, class of protection I in line with VDE 411 b. Power consumption typ. 115 W, max. 180 W with all options c. Safety in line with EN 61010-1, IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1-4 d. Test mark VDE, GS, CSA, CSA-NRTL yy) Weight and dimensions: a. Dimensions: W × H × D 412 mm × 197 mm × 417 mm 16.22 in × 7.76 in × 16.42 in b. Net weight without options, nominal: 24.46 lb. zz) Ruggedized Housing with carrying handle aaa) OCXO PRECISION REFERENCE FREQUENCY (10MHZ) Delivery Date: Delivery shall be no later than 5 weeks after award of contract. Invoicing: All invoicing shall be submitting into Wide Area Workflow for payment after ALL material is received in the condition as stated. Place of Delivery: The items above must be delivered to the following address: COMMANDER, NAVAIR Calibration Standards, MCAS, Attn: Lou Cerrillo, (UIC N48535) Building 612, Bay 9, Beaufort, SC 29904. This notice is not a request for competitive proposals. All responsible interested parties may submit a capability statement by 4:00 p.m. on 18 September 2019 via e-mail to linda.loving@navy.mil. Capability Statements will be considered solely for the purposes of determining whether to conduct a competitive procurement. The Government shall not reimburse interested sources for any information provided nor return any information provided. Offerors must ensure that their firm is registered with the System for Award Management (SAM). For further information, please refer to https://www.sam.gov.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVAIR/N00421/1300802323/listing.html)
- Place of Performance
- Address: Patuxent River, Maryland, 20670, United States
- Zip Code: 20670
- Zip Code: 20670
- Record
- SN05429203-W 20190905/190903231330-655758f8201859e8b19177e505c6c20e (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |