Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 17, 2019 FBO #6505
DOCUMENT

65 -- Electrosurgical Unit | 654-19-3-055-0176 - Attachment

Notice Date
9/15/2019
 
Notice Type
Attachment
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office (NCO 21);VA Northern California HealthCare System;5342 Dudley Blvd, Bldg 209;McClellan CA 95652-2609
 
ZIP Code
95652-2609
 
Solicitation Number
36C26119Q1301
 
Response Due
9/19/2019
 
Archive Date
10/4/2019
 
Point of Contact
Sidney R Davis
 
E-Mail Address
923-4550<br
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Brand Name or Equal Worksheet ( Salient Characteristics ) v 2.0 8/15/2019 The technical POC will use the characteristics on this worksheet to determine if any alternate offers meet the government s requirements. To that end, please describe the essential characteristics of the brand name item that make it what the Government needs. Not all characteristics will necessarily apply (e.g., do not include weight unless weight is actually important). Brand Name Item: Electrosurgical Unit: Monopolar/Bipolar Essential/significant physical, functional, or performance characteristics. Easy to use touch screen setup, Six coagulation settings, six combinations of initiation and cutting settings. Able to read tissue 434,000 times per second. Dedicated footswitch for activating bipolar cut and coagulation. Compatibility With existing supplies. Dimensions Weight- Industry/Government Standard FDA approved Purpose Designed for targeted endovenous therapy Governing Body or Organization Device must be FDA approved for its intended use. Meet electrical safety requirements as set forth in NFPA 99. Other Mobile cart for the electrosurgical unit. Trade-in credit of $4200 for 7 ValleyLab Forces FX Generators. Two-year extended warranty. Complete generic identification Electrosurgical Unit: Monopolar/Bipolar Applicable model/make/catalog number ValleyLab FT10 Energy Platform Manufacturer name Medtronic Per VAAR 811.104 and 811.105, I certify the following regarding the above information: The salient characteristics listed above are essential to the Government s requirements. To my knowledge, the restrictions listed above will not limit the acquisition to an item peculiar to one manufacture. Name, Date: Pam Miller, Administrative Nurse Surgery Service May 2019 _______________________________________
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANCHCS/VANCHCS/36C26119Q1301/listing.html)
 
Document(s)
Attachment
 
File Name: 36C26119Q1301 36C26119Q1301.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=5156147&FileName=36C26119Q1301-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=5156147&FileName=36C26119Q1301-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN05445133-W 20190917/190915230044-ef3b0057a8f06c50a4cf9b9700def29f (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.