MODIFICATION
13 -- MK 38 Cables for the 25MM Machine Gun Systems
- Notice Date
- 10/8/2019
- Notice Type
- Modification/Amendment
- NAICS
- 332618
— Other Fabricated Wire Product Manufacturing
- Contracting Office
- Department of the Navy, Naval Sea Systems Command, NSWC IHEODTD, 4081 N. Jackson Rd. Bldg 841, Indian Head, Maryland, 20640-5116, United States
- ZIP Code
- 20640-5116
- Solicitation Number
- N00174-19-R-0157
- Point of Contact
- Michael J. Anthony,
- E-Mail Address
-
michael.anthony@navy.mil
(michael.anthony@navy.mil)
- Small Business Set-Aside
- N/A
- Description
- SYNOPSIS: MK 38 Cables for the 25MM Machine Gun Systems The Naval Surface Warfare Center, Indian Head Explosive Ordnance Disposal Technology Division (NSWC IHEODTD) - Picatinny Detachment, is re-soliciting previously synopsized procurement of (3) types of bulk cables (W3, W1, W51) to be used in creating the cable assemblies during shipboard installation of the MK 38 MOD 2/3 for the 25MM Machine Gun Systems. Solicitation N0017419-R-0157 will be re-solicited as a Firm Fixed Price Full and Open Competition acquisition. The NAICS code is 332618. The intended contract will consist of a base year only. This synopsis is for information purposes only. The Request for Proposal (RFP) will be posted to the Federal Business Opportunities website approximately fifteen (15) days follow this pre-solicitation post. MK 38 Cable Requirements are as follows: W3 - 52 conductors (Orion Wire Company Part Number CMB-12200329-LSZHBK) •18 x M27500-22SB2T23 - Cable, 2 Wires, 22 AWG 19/34 Stranded, 9/96-9 •3 x M27500-22SB3T23 - Cable, 3 Wires, 22 AWG 19/34 Stranded, 9/96/93-9 •3 x low loss triaxial video cable o75 Ohm nominal characteristic impedance center conductor to inner shield o17 pf per foot center conductor to inner shield o81% nominal velocity of propagation o28 AWG 7/36 silver plated copper or copper alloy center conductor oLess than 74 Ohms per 1000 feet for center conductor oInner and outer shield minimum 38 AWG tinned copper braid, 90% minimum coverage oMaximum working voltage 1,000V •2 x M27500-12SB2T23 - Cable, 2 Wires, 12 AWG 19/29 Stranded 9/96-9 •Shielding - 34 AWG tinned copper braid, 90% min coverage •Jacket -.060" black low-smoke / zero halogen polyethylene to.983" ±.025" OD •Minimum bend radius of 10" W1 - 19 conductors (Orion Wire Company Part Number CMB-12200331-LSZHBK) •4 x M27500-12SB2T23 - Cable, 2 Wires, 12 AWG 19/29 Stranded, 9/96-9 •4 x M27500-20SB2T23 - Cable, 2 Wires, 20 AWG 19/32 Stranded, 9/96-9 •1 x M27500-20SB3T23 - Cable, 3 Wires, 20 AWG 19/32 Stranded, 9/96/93-9 •Shielding - 34 AWG tinned copper braid, 90% min coverage •Jacket -.050" black low-smoke / zero halogen polyethylene to.830" ±.025" OD •Minimum bend radius of 8.5" W51 - 12 conductors (Orion Wire Company Part Number CMB-12200330-LSZHBK) •4 x M27500-22SB3T23 - Cable, 3 Wires, 22 AWG 19/34 stranded •Shielding - 36 AWG tinned copper braid, 90% min coverage •Jacket -.035" black low-smoke / zero halogen polyethylene to.405" ±.015" OD •Minimum bend radius of 4" Assemble cables using filler(s) and binder tape as required Any inquiries should be submitted via electronic mail to: Michael Anthony Email: michael.anthony@navy.mil
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVSEA/N00174/N00174-19-R-0157/listing.html)
- Record
- SN05470674-W 20191010/191008230551-14834909cb4c55ab81bc4a48fedde193 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |