Z -- Service/Repair Sub Stations A, B, C, Exchange, Stadium, McCard, Bldg.1002 Fiber Optic Cable & Siemens Service Support
- Notice Date
- 10/8/2019
- Notice Type
- Award Notice
- NAICS
- 561210
— Facilities Support Services
- Contracting Office
- Department of the Navy, Naval Facilities Engineering Command, NAVFAC Washington, Chesapeake, ROICC Quantico, Building 2004, PO Box 1855, Marine Corps Base, Quantico, Virginia, 22134-0855
- ZIP Code
- 22134-0855
- Solicitation Number
- N40080-19-Q-1024
- Archive Date
- 10/12/2019
- Point of Contact
- Larry D. Curtis, Phone: 7037841079
- E-Mail Address
-
larry.d.curtis1@navy.mil
(larry.d.curtis1@navy.mil)
- Small Business Set-Aside
- N/A
- Award Number
- N40080-19-P-1024
- Award Date
- 9/27/2019
- Awardee
- Romem Aqua Systems Company, Inc, 1635-2 Woodside Drive <br />, <br />, Woodbridge, 22191-3045, United States
- Award Amount
- $158,710.00
- Description
- Maintenance and repairs to be completed at Electrical Sub Stations, 12, A, B, and C •· Replace existing indicating lights with new LED style lights. •· Install new batteries and battery charger at Sub Station-12. •· Test clean and provide preventive maintenance. •· Provide report with recommendations of any additional repairs. •· Work will be performed on Saturdays, Working hours will be 7am to 5pm. •· Power outages will be scheduled for each station being serviced/repaired. •· Old battery disposal will be the responsibility of the contractor. •· Provide qualified personnel and PPE for all work to be performed. •· Remove and re-install equipment covers. •· Open and close equipment doors •· Provide a schedule, work plan and safety plan. •· Oil samples will be included. Electrical Sub Station-12: Medium Voltage (MV) Switchgear, qty-1 WV Vacuum Breaker, qty-5 PT set or CPT, qty-5 Relay-Overcurrent - 1/Phase 50/51, qty-16 Relay-AC Directional Overcurrent 67, qty-8 Battery & Charger, qty-1 Meter-Voltmeter, Ammeter and Frequency, qty-4 Repair or Replace MV CB Motor Operator, qty-2 Install new Gel type battery, qty-1 Electrical Sub Station-A: Medium Voltage (MV) Switchgear, qty-1 MV Transformer-Liquid Filled, up to 5000Kva, qty-1 WV Vacuum Breaker, qty-6 PT set or CPT, qty-2 Relay-Overcurrent - 1/Phase 50/51, qty-13 Relay-AC Directional Overcurrent 67, qty-8 Battery & Charger, qty-1 Meter-Voltmeter, Ammeter and Frequency, qty-6 Electrical Sub Station-B: Medium Voltage (MV) Switchgear, qty-1 MV Transformer-Liquid Filled, up to 5000Kva, qty-1 WV Vacuum Breaker, qty-8 PT set or CPT, qty-5 Panel board (<600V), qty-1 Relay-Overcurrent - 1/Phase 50/51, qty-21 Relay-AC Directional Overcurrent 67, qty-8 Battery & Charger, qty-1 Meter-Voltmeter, Ammeter and Frequency, qty-8 S&C Oil Switch, qty-1 Electrical Sub Station-C: Medium Voltage (MV) Switchgear, qty-1 MV Transformer-Liquid Filled, up to 5000Kva, qty-1 WV Vacuum Breaker, qty-7 PT set or CPT, qty-5 Panel board (<600V), qty-1 Relay-Overcurrent - 1/Phase 50/51, qty-21 Relay-AC Directional Overcurrent 67, qty-8 Battery & Charger, qty-1 Meter-Voltmeter, Ammeter and Frequency, qty-8 Building 1002 Fiber Optic Cable Installation: •· Install new steel messenger cable on existing utility poles for fiber optic cable installation. •· Install new aerial fiber optic cable and lash to new messenger cable as specified from Building 1002 to Building 122. •· Install new rigid galvanized conduit on the exterior of both buildings to specified areas for the fiber optic cable installation. Exclusions: •· Any new utility poles. •· Any terminations or devices for the fiber optic cable. ------------------------------------------------------------------------------------------------- Siemens Service Support: •· Contractor shall furnish on-site Siemens service support for (10) ten days, provide support as directed by customer. •· Install a Siemens Industry, Inc. environmental control, energy management and/or building automation system in accordance with plans and specifications. ------------------------------------------------------------------------------------------------- Stadium, Exchange and McCard substations: •· Contractor shall inspect the Stadium curves and relay times in association with, McCard and exchange feed. Relay timings need to be adjusted so that exchange relays is not affected by Mccard outages. Typically exchange relay opens when Mccard relay opens, this needs to be corrected and tested.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVFAC/N62477QUAN/Awards/N40080-19-P-1024.html)
- Record
- SN05470811-W 20191010/191008230620-5cd6e8ecb97c0232cce339948e6e3f5a (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |