DOCUMENT
66 -- Copy of Surface Plasmon Resonance (SRP) (VA-19-00070294) - Attachment
- Notice Date
- 11/5/2019
- Notice Type
- Attachment
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- US Department of Veterans Affairs;Veterans Health Administration;Regional Procurement Office (RPO) East;323 North Shore Drive, Suite 500;Pittsburgh PA 15212-5319
- ZIP Code
- 15212-5319
- Solicitation Number
- 36C24E20Q0021
- Archive Date
- 11/5/2019
- Point of Contact
- Elaine F DiBucci
- E-Mail Address
-
822-3432<br
- Small Business Set-Aside
- N/A
- Description
- The Veterans Administration, Augusta VA intends to negotiate on a sole source basis with Nicoyalife for Open SPR-XT and components The VA requires a benchtop surface plasmon resonance (SPR) instrument to provide high quality, label-free interaction analysis. The Surface Plasmon Resonance (SPR) will be used to determine the interaction between aquaporin-3 (AQP3) and phospholipase D2 (PLD2), which is crucial to the anti- inflammatory action of AQP3 and glycerol, as it allows the glycerol transported by AQP3 to the converted to phosphatidylglycerol (PG) by the action of PLD2. PG, in turn, suppresses inflammation by inhibiting the activation of toll-like receptors (TLRs) of the innate immune system. The principal investigator would also use the SPR to examine the interaction between PG and TLRs and TLR co-receptors in order to generate preliminary data (see salient characteristics below). This notice of intent is not a request for competitive proposals; however, any responsible source who believes it is capable of meeting the requirement and who is the Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller of all the items listed above, may submit a capability statement to the contracting office to the contracting office no later than Monday, November 11, 2019, 4:00 PM EST. Interest/capability statements may be sent to Elaine DiBucci at elaine.dibucci@va.gov. No telephone responses will be accepted. A determination not to compete the proposed requirement based upon the responses to this notice is solely within the discretion of the Government. OPN-STR-R4.2-XT : -1 OpenSPR-XT 2-Channel Instrument -1 OpenSPR-XT PC Software -1 100 L Sample Loop (installed in OpenSPR-XT) -1 Flow Cell (installed in OpenSPR-XT) -3 250 mL Buffer Bottles with Fitted Tubing Caps -1 500 mL Waste Bottle with Fitted Tubing Cap -10 96-Well Plates -10 Well Plate Foils -1 Training Kit -1 OpenSPR Accessory Kit (Tweezers, Install USB, Tool Set) -1 XT Autosampler Accessory Kit (2x 48-vialadapters, 2x fuses, needle stripper spacer tool,air needle, PEEK connector kit) -1 Wash Solvent Bottle with Adapter -2 Silicon drain hoses -2 USB A-B Cables -1 OpenSPR Power Cord -1 XT Autosampler Power Cord (USA and EUR) -1 6pk Standard Sensors -1 Year Warranty TDS-P l kinetic analysis software; Including laptop with OpenSPR and Trace Drawer preinstalled and preconfigured. SSP-1 3 COOH Sensor Chips 3 NTA Sensor Chips 3 Streptavidin Sensor Chips 1 3x Reaction Amine Coupling Kit 1 NTA Coupling Kit SEN-AU-100-10-LIP1Lipsome (LIP-1) (Pack of 10) LIP-RK (reagents to immobilize and remove liposome-based ligands on and off Lipsome (LIP-1) Sensor Chips. REGOPT Optimization kit includes: -MgCl2 4M (25 mL) -NaOH 0.2M (25 mL) -SDS 0.5%(25 mL) -NaCl 5M(25 mL) -Glycine-HCl pH at 4 pH values (25 mL) SPARE-R4-XT Spare Part Kits includes: -1 Flow cell -1 100 uL Sample Loop -1 Injection Port -1 LED Light Source -1 Replacement Tubing Kit -10 Ferrules -4 Nuts - Finger Tightening -1 Bulk Head -1 Spline Wrench -Replacement Valve Rotor Seal for XT -Replacement XT Injection Needle with Connections -Replacement Transit Tube with connections for XT -Replacement Syringe for XT -Replacement Syringe Valve for XT MNT Maintenance Kit includes: 1x Cleaning Kit 1x Declogging Kit Including Training, 2 Year extended warranty, shipping
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/170585ea1d3f9ba02f50fcad6952e6b7)
- Document(s)
- Attachment
- File Name: 36C24E20Q0021 36C24E20Q0021.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=5214693&FileName=36C24E20Q0021-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=5214693&FileName=36C24E20Q0021-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: 36C24E20Q0021 36C24E20Q0021.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=5214693&FileName=36C24E20Q0021-000.docx)
- Record
- SN05489842-W 20191107/191105230534-170585ea1d3f9ba02f50fcad6952e6b7 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |