Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 08, 2019 SAM #6583
SOURCES SOUGHT

J -- Replace and install condensate return repairs

Notice Date
12/6/2019 12:47:18 PM
 
Notice Type
Sources Sought
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
242-NETWORK CONTRACT OFFICE 02 (36C242) ALBANY NY 12208 USA
 
ZIP Code
12208
 
Solicitation Number
36C24220Q0153
 
Response Due
12/13/2019 8:59:59 PM
 
Archive Date
12/30/2019
 
Point of Contact
Jacob.Burg@VA.gov
 
E-Mail Address
JACOB.BURG@VA.GOV
(JACOB.BURG@VA.GOV)
 
Awardee
null
 
Description
This is a Sources Sought Notice:(a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited.(b) Although ""proposal,"" ""offeror,"" contractor, and ""offeror"" may be used in this Sources Sought Notice, any response will be treated as information only. It shall not be used as a proposal.(c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as ""proprietary"" or ""confidential,"" intended to restrict distribution will not be distributed outside of the Government, except as required by law. (d) This Sources Sought is issued by VISN 2 Contracting Office in Cheektowaga, NY for the purpose of collecting information about partial replacement of low-pressure steam condensate return risers and installation of new medium-pressure supply and return at East Orange Veterans Hospital, NJ 07018. The VA is seeking to provide for this requirement starting in January 2020. The NAICS code identified for this requirement is 238220 Plumbing, Heating, and Air-Conditioning Contractors. The requirement is detailed in the Statement of Work section of this document. (e) Cursory market research has identified several small businesses that may be able to provide for this requirement. Contractors that can meet the requirements in the attachment are encouraged to email a capability statement and full information to Jacob Burg at Jacob.Burg@VA.gov- Part of the purpose of this Sources Sought Notice is to determine the viability of set aside to a specific socio-economic category. Contractors shall identify the NAICS code for the services being offered as well as their size status under said NAICS. If contractor is a Service-Disabled Veteran Owned Small Business (SDVOSB), a Veteran Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. - Contractors shall also identify any Federal Supply Schedules that may carry the desired services. - Contractors shall identify pertinent point of contact for company, contractor DUNS number for size standard and socioeconomic verification in SAM and VIP.- Contractors shall include any relevant comments about the Attachment(s) if applicable. VA New Jersey Healthcare System385 Tremont AvenueEast Orange, New Jersey 070181. Background: Currently Bldg. 1 D-wing floors A through 5 have low pressure condensate return risers that are leaking. The leaking sections need to be removed and replaced. Currently Radiation Oncology s steam risers are inactive, and an alternate steam riser(s) are needed.2. Scope of Work: Contractor shall furnish all labor and materials to provide complete scope of work for Bldg.1 steam supply and condensate return risers in accordance with VA specifications for the VA NJ Health Care System, East Orange, NJ. 3. Statement of Objectives: Partial replacement of a low-pressure steam condensate return risersInstallation of new medium-pressure supply and return.4. Required Results: Bldg. 1 A level-3rd floor replacement of leaking low pressure condensate return risers.Bldg.1 B level A level installation of new MPS/MPR for Radiation Oncology.Work shall include but not be limited to removal of existing steam condensate return piping originating in the A level file rm. (A-250) crawlspace and terminate in the existential space above the museum ceiling (2nd Floor Elevation). Remove and dispose of approximately 120LF of 1 1/4 and 60LF of 1 schedule 40 black pipe, associated fittings and insulation.Furnish and install approximately 120LF of 1 � and 60LF of 1 schedule 80 pipe. Schedule 40 for all associated fittings. Approximately 120 LF of insulation for 1 � IPS piping and 60LF of insulation for of 1 IPS piping. Piping locations sometimes runs adjacent to or near existing piping or modified locations. Routing to be determined by contractor. Will require core drilling in multiple locations up to ten locations.May require scaffolding or platform work to accomplish tasks (to be determined by contractor).Paint exposed piping and insulation in museum flat black to blend into exhibit background.Fabricate any soffits or pipe chases needed to enclose said piping.Furnish and install approximately 180LF of 1 � Medium Pressure Steam Schedule 40 pipe and 180LF of Medium Pressure Condensate Return 1 schedule 80 pipe. Schedule 40 for all associated fittings. Approximately 180 LF of insulation for 1 � IPS piping and 180LF of insulation for of 1 IPS piping. Tie into existing 4 MPS Supply and 3 Return located on B-Level Shaft #5 and termination in A-level Mechanical room A-236E. Pipe routing to be determined by contractor. Immediately after receiving the contract award, the Contractor shall;Provide all necessary Labor, Material and equipment to perform the required work to provide fully functional system.Re-commission the system and prepare for system reactivation.Repair/replace piping insulation and provide ID/ labeling as necessary to replace original ID/Labeling. 5. Location of Performance: Bldg. 1 floors A through 56. Period of Performance: Contractor to start immediately after receiving award, estimate completion time is 60 calendar days.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/6957569cee8f437fb0c82149c9d7586c/view)
 
Place of Performance
Address: New Jersey Health Care System;VA East Orange Campus;385 Tremont Avenue;East Orange, NJ 07018
Zip Code: 07018
 
Record
SN05511387-F 20191208/191206230253 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.