Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 12, 2019 SAM #6587
SOURCES SOUGHT

65 -- Cryostar NX50 Closes 12/18/2019 4:00PM EST

Notice Date
12/10/2019 12:23:12 PM
 
Notice Type
Sources Sought
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
244-NETWORK CONTRACT OFFICE 4 (36C244) PITTSBURGH PA 15215 USA
 
ZIP Code
15215
 
Solicitation Number
36C24420Q0155
 
Response Due
12/18/2019 8:59:59 PM
 
Archive Date
02/16/2020
 
Point of Contact
Amanda L. Williamsamanda.williams4@va.gov
 
E-Mail Address
amanda.williams4@va.gov
(amanda.williams4@va.gov)
 
Awardee
null
 
Description
Purpose and Objectives: The intent of this Sources Sought Notice is to identify potential businesses especially any Serviced Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses and any other Small Business concerns capable of providing a Cryostar NX50 research equipment as listed in the below Statement of Need. These are for the VA Medical Center in Pittsburgh, PA 15240. Responses to this Sources Sought Notice should demonstrate the firm's ability, capability, and responsibility to provide the principal components of supplies listed in the Statement of Need. Responses should include the following information: Business name, address, Point of Contact, Business size and representations of your business (SDVOSB, VOSB, Hubzone, WOSB, Large Business, etc.) and if you are a manufacturer or distributor of the items. All information is to be submitted via e-mail at Amanda.Williams4@va.gov. Information provided will not be returned. All responses shall be in the English Language. Responses are due by 4:00 pm (EST) on Wednesday, December 18, 2019. No submissions will be accepted after this date and time. Questions can be submitted electronically to Amanda.Williams4@va.gov. This is a Sources Sought Notice and submissions will be used for informational and planning purposes only. This notice does not constitute a formal Request for Quote (RFQ), nor is the government obligated to issue an RFQ. In addition, the Government does not intend to pay for any information provided under this notice. The Government is not obligated to notify respondents of the results of this survey. STATEMENT OF NEED:PurposeOur new project will require us to conduct a large amount of imaging experiments to assess brain lesion, changes in expression of multiple proteins with immunofluorescence staining, and morphological structural changes of tissue and cell bodies. The Cryostar NX50 from Thermo Fisher is a high-performance cryostat that we require for preparing optimal tissue slices for the previously listed experiments from fragile tissues of adult mouse brains. This cryostat offers many unique benefits that will allow us to obtain the best tissue sectioning possible for our required imaging experiments. RequirementsThe system should provide the following:Touch screen interface and intuitive software allows the user to view and adjust the following parameters: temperature, section thickness, remaining blade holder travel, sectioning and trimming thickness and all other instrument settings. Standby mode for energy savings and noise reduction. Green instrument 0.30kW/hr measured during a regular day running mode (7.2kW/day). Specimen retraction. Body contoured design positions the user closer to the chamber and the microtome Manual handwheel lock secures the upper position of specimen head. 42L large open Stainless-steel cryochamber. Cryobar holds 18 freezing stations and one fast freezing station.Constantly cooled chamber at a temperature of -25�C+/-2�C at ambient temperature of +20�C Constantly cooled knife holder at a temperature of -27�C to -20�C +/-2�C at 20�C to 30�C ambient.Active Object head cooling -43�C+/-2�C at 20�C ambient The object head temperature can be user defined.Integrated Peltier fast-freezing device -57�C +/-3�C at 20�C ambient with separate cooling element.Sliding glass door with integrated LED lightingChoice of immediate or scheduled defrost cycleColor coded specimen chucks help to identify specimens.Rapid response temperature-controlled object head.Specimen orientation on orbital 80 XY axis and specimen rotation on Z axis.Section thickness from 0.5 to 500 m.Vertical specimen stroke of 64mm.Blade carrier horizontal feed range of 48mm.Highly stable knife holder delivers consistent section thickness.Specimen Holder Moves vertically only for sectioning, reducing vibration.Knife advances horizontally towards the sample.Microtome with precise stepping motor advanceAutomated retraction feature which can be switched on or off.Light-touch handwheel minimizes the risk of repetitive motion injury (repetitive strain).Maintenance-free cross-roller bearings Blade carrier for low-profile, high-profile, and c-knife blades Magnetic blade transfer tool supports safe removal of the blade from the blade holder reducing risk of potential injury.Protective blade guard acts as a barrier between the operator and the blade.Removable section waste trayItem #Description/Part Number*Qty957250HCRYOSTAR NX50 HIGH PROFILE1NC1572419STEEL KNIFE CARRIER11407025KNIFE-16CM C PROFILE STEEL2
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/86b66b802b7d407ca113d849aa8ecb15/view)
 
Place of Performance
Address: VA Pittsburgh Healthcare System;University Drive Campus;University Drive;Pittsburgh, PA 15240
Zip Code: 15240
 
Record
SN05513528-F 20191212/191210230255 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.