Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 13, 2019 SAM #6588
SPECIAL NOTICE

66 -- KEYENCE BZX FLOURESCENCE MICROSCOPE Intent to Sole Source

Notice Date
12/11/2019 7:48:24 AM
 
Notice Type
Special Notice
 
NAICS
333314 — Optical Instrument and Lens Manufacturing
 
Contracting Office
RPO EAST (36C24E) PITTSBURGH PA 15212 USA
 
ZIP Code
15212
 
Solicitation Number
36C24E20Q0035
 
Archive Date
03/10/2020
 
Point of Contact
Contracting Officer: Michael HaydoEmail: michael.haydo@va.gov
 
E-Mail Address
Michael.Haydo@va.gov
(Michael.Haydo@va.gov)
 
Awardee
null
 
Description
The Veteran s Administration (VA) Office of Research and Development, Regional Procurement Office East in Pittsburgh, PA intends to negotiate on a sole source basis with Keyence Corporation of America based in Woodcliff Lake, NJ. on behalf of the Buffalo VA Medical Center located in Buffalo, NY. Salient CharacteristicsSystem Components: ItemQTYBZ-X810 Keyence BZX Fluorescence Microscope Head1BZ-X800E Keyence BZX Fluorescence Microscope Controller1Keyence BZ Support Package 1BZ-H4XD Keyence BZX Hardware Module (Multi-Stack)1BZ-H4XF Keyence BZX Hardware Module (Sectioning)1BZ-H4XI BZX Hardware Module (Cytometer)1BZ-H4XT Keyence BZX Hardware Module (Time Lapse)1972082 Keyence KIW (MIX) TOKAIHIT (100% CO2)1BZ-H4A Keyence BZX Software (Image Analyzer Software)2BZ-H4R Keyence BZX Software (3D Analysis)2BZ-H4M Keyence BZX Software (BZX Measurement Module)2BZ-H4C BZX Software (Hybrid Cell Count Software)2BZ-H4CM Keyence BZX Software (Macro Cell Count)2BZ-H4K Keyence BZX Software (Motion Analysis)2OP-87762 Keyence BZX Accessory (Dapi Filter)1OP-87763 Keyence BZX Accessory (GFP Filter)1OP-87765 Keyence BZX Accessory (Texas Red Filter)1OP-87766 Keyence BZX Accessory (Cy5 Filter)1OP-87764 BZX Accessory (TRITC Filter)1972029 Keyence BZ Nikon Objective Lens (APO 2X LAMBDA)1972030 BZ NIKON OBJECTIVE LENS (APO 4X LAMBDA)1972031 Keyence BZ Nikon Objective Lens (APO 10X LAMBDA)1972032 Keyence BZ Nikon Objective Lens (APO 20X LAMBDA)1972033 Keyence BZ Nikon Objective Lens (APO 40X LAMBDA)1972036 Keyence BZ Nikon Objective Lens (APO 60X OIL LAMBDA)1972326 Win10 PC for BZ-X801972072B 23'' Monitor1972037 Keyence BZ Nikon Objective Lens (APO 100X Oil LAMBDA)1972081 BZ NIKON OBJECTIVE LENS (4X PHASE) CFI PLAN FLUOR1971936 BZ NIKON OBJECTIVE LENS (10X PHASE) CFI PLAN FLUOR1971962 BZ NIKON OBJECTIVE LENS (20x PHASE) CFI PLAN FLUOR1971963 BZ Nikon Objective Lens (40X Phase) CFI PLAN FLUOR1INSTALLATION: Installation and Training Included1WARRANTY: Min 1-Year Warranty Included From Keyence1Shipping Included - No Cost to the Government1This instrument shall be delivered and installed at the VA in Western New York.Minimum Specifications:The requirement is for one Keyence BZ-800e fluorescent microscopic system that meets or exceeds the following specifications:A fully-integrated, inverted fluorescent microscope system microscope system that provides a full imaging range including software controlled and automated motorized stage and camera system. Wide range of fluorescent filter capabilities to include the capability to capture: DAPI, GFP, Texas Red, Cy5, and TRITC wavelengths and standard bright field. Multiple objectives for a wide viewing range including 2X, 4X, 10X, 20X, and 40X, 60X (oil), and 100X (oil) magnifications, as well as 4X, 10X, 20X, and 40X phase contrasted ranges.Mounting adaptors to allow collection of images from slides, chambers, petri dishes, and tissue culture flasks. Custom modules to include Multi-stack, sectioning, image cytometer, time lapse.Navigation function where the observation point moves to a specific location on a wide-area map image, enabling high-magnification observation and an overall picture with a wide-area image keyed to the XY stage coordinate information. All mountable lenses shall allow the generation of a wide-area map image. Image stitching functionality (maximum of 50,000 x 50,000 pixels) captured via the automatic range set-up when using any mountable lens.Optical sectioning that is unaffected by fluorescence blurring during fluorescence imaging should be possible. Fully integrated microscope control software and image analysis for quantitation of captured still and video images. Software includes functionality that automatically selects cells based on contour and color contrast and automatically takes count and calculates the area, perimeter, Feret diameter, longest diameter, shortest diameter, and the integrated value of luminance. There should also be a function that uses the selected image information as a mask area to perform automatic counting upon re-setting the conditions for the images in each area, also enabling an easy measurement of area ratio, etc.The system should enable outputting, as a conditions file, of measurement conditions used with the automatic counting function. Furthermore, the system should have a macro processing function that performs automatic counting on multiple image files at once with the same conditions based on the conditions file.Equipped with a function that records videos at a frame rate of 95 fps or higher and images should be recorded at 12,000,000 pixels or more.Allows for mounting of temperature/CO2 regulated chamber for time-lapse imaging. The mounted chamber shall allow for multi-well plates to be set inside.Capable of transforming z-stacks into 3D renderings with a single click to accurately observe three-dimensional structures. Cytometer function that scans wells with uniform conditions for high reproducibility of data.Microscope, filters, and camera constructed inside a covered, Dark room simulated environmentThe features of the Axiovert A1 FL inverted microscope to include the following capabilities:Ability to visualize multiple muscle fiber types (up to 4 types simultaneously) using multi-channel fluorescent capabilities. Capture of muscle stem cell pre- and post-differentiated states, including size and cross-bridging analysis of mature myotubes. Capture of bone marrow stem cells.Imaging of mature osteoclast for quantitation and size measurement.Imaging of alizarin red and alkaline phosphatase stained osteoblast tissue culture plates.Imaging of oil-red-O staining of muscle fibers and liver histological samples for assessment of fat content.Capture of multi-tissue (Muscle, liver, adipocytes, cardiac, kidney) hemotoxilin and Eosin staining for structural and physiological assessment.Cell quantitation of seahorse extracellular flux analysis tissue culture plates to normalize cellular respiration data.Multi-color imaging of protein biomarkers in brain, muscle, liver, and bone tissues.Visualization of astrocytes and other brain derived cell types. Investigation of cellular RNA trafficking and looking into cells to investigate the kinetics and steady-state outcomes of catalytic RNA (ribozyme) therapeutics on specific target mRNAs and their cognate proteins.Investigation of real time ribozyme kinetics in live cells exploiting fluorescent RNA aptamer technology.Facilitate deeper investigations that include characterizing specific hematopoietic subtypes and macrophage polarization using the novel Z-stacking capabilities.Investigation of cardiac stem cell mediated repair using multiple fluorescence imaging and the quantitation of features to elucidate adult stem cells stimulation of endogenous myocyte proliferation.Imaging of iPSC-derived midbrain dopaminergic (DA) neurons, to better understand the impacts of parkin mutations as a model of idiopathic Parkinson s disease.Capture of high-resolution images of multi-channel fluorescent stains as well as automate imaging and quantification of large sections of tissue, thus augmenting the ability to compare the effectiveness of the exosome-based therapies as well as streamline the workflow process.The requirement will take place at a VA facility in Buffalo, NY. The sole source is pursuant to FAR 6.302-1 Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements. This notice of intent is not a request for competitive proposals, however; any responsible Disabled Veteran Owned Small Business, or Veteran Owned Small Business source who believes it is capable of meeting or exceeding the requirement may submit a capability statement and supporting documentation to the contracting office no later than Tuesday, December 17, 2019, (10:00 AM, EST). Interest/capability statements may be sent to Michael Haydo at Michael.haydo@va.gov. No telephone responses will be accepted. A determination not to compete the proposed requirement based upon the responses to this notice is solely within the discretion of the Government.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/1038c562bb384b38bfe69e230c190444/view)
 
Record
SN05513797-F 20191213/191211230303 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.