Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 13, 2019 SAM #6588
SOLICITATION NOTICE

J -- 619-20-1-5243-0008 Emergency Generator PM & MAINTENANCE (VA-19-00054180)

Notice Date
12/11/2019 5:01:31 PM
 
Notice Type
Solicitation
 
NAICS
811310 — Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
 
Contracting Office
247-NETWORK CONTRACT OFFICE 7 (36C247) AUGUSTA GA 30904 USA
 
ZIP Code
30904
 
Solicitation Number
36C24720Q0100
 
Response Due
12/13/2019 8:59:59 PM
 
Archive Date
12/28/2019
 
Point of Contact
Earnest EllisonContract Specialist334-272-4670, x2041
 
E-Mail Address
Earnest.Ellison@va.gov
(Earnest.Ellison@va.gov)
 
Awardee
null
 
Description
PERFORMANCE BASED WORK STATEMENTDIESEL GENERATORSInspections, Preventive Maintenance, TestingCentral Alabama Veterans Healthcare System (East and West Campuses)SCOPE OF WORK:The contractor shall provide all labor, equipment, tools, materials, supervision, test equipment, travel and transportation necessary to perform annual preventive maintenance and inspections of the diesel generators along with checking the switchgears for each of the 15 listed generators in accordance with current NFPA 99 and NFPA 100 testing and maintenance activities. Inspections shall include, but not limited to, assessing the prime mover s exhaust gas temperature against the minimum temperature recommended by the manufacturer (this information must be on the report). Annually, the contractor shall provide a minimum of four (4) continuous hours load bank with at least 30% of the nameplate rating to perform test. During the test, the dummy or load bank must be arranged so that it could be disconnected if power was lost to each facility and the generator was needed for Medical Center s use. This annual inspection (of the generators, etc.) must be accomplished during the month of August. PERIOD OF PERFORMANCE: This contract is for a base year with (2) one-year option. The days and hours of operation is Monday thru Friday 8:00 a.m. to 4:30 p.m. excluding Federal holidays. III. EQUIPMENT DESCRIPTION:Diesel Generators with manufacturer, model, location and size located at CAVHCS (East Campus), 2400 Hospital Road Tuskegee, AL and CAVHCS (West Campus), 215 Perry Hill Rd, Montgomery, AL.WEST CAMPUSMANUFACTURERMODELLOCATIONKWVOLTAGE OUTPUTKohler125RE02JBBuilding 14125 kw208 VKohler80RE02JFBuilding 481 kw277 VCaterpillar2A300287Building 1 Chiller Plant800 kw480 VCaterpillar 1572RSL2037A-P00 WBuilding 1440 kw277 VCaterpillar 2572RSL2037A-P00 WBuilding 1440 kw277 VEAST CAMPUSMANUFACTURERMODELLOCATIONKWVOLTAGE OUTPUTKohler10478911Building 5600750Perkins 2 EA2206D-E13TAG3Building 121400500Cummins5AT1224552C1Building 12350438Kohler80RZI81Building 1580kvaCummins KohlerSC534ES350R0ZD71Building 120450350563438Kohler600R0ZDBuilding 129600750Cummins500FDR5051FF-WBuilding 124300375Kohler150REOZ5BBuilding 90160200Cummins500FDR5051FF-WBuilding 123300375Hi power portableBuilding 1330kvaHi power portableBuilding 1330kvaHi power portableBuilding 1330kvaIV. PERFORMANCE REQUIREMENTS: Diesel powered emergency generators shall be exercised for FOUR (4) continuous hoursannually with supplemental loads of:30 percent of nameplate rating for sixty (60) minutes, followed by;50 percent of nameplate rating for sixty (60) minutes, followed by;75 percent of nameplate rating for 120 minutes for a total of four continuous hours.The contractor s inspection shall include the following:Check exciter brushesCheck for ground fault currentCheck all safety alarmsCheck all shutdown systemsCheck operation of emersion heaterObserve operation of governor during start-up, accepting load and shutdownCheck operation of remote safety alarms in Boiler Plant.The contractor s mechanical personnel shall:Check over-speed shutdownCheck cylinder head mechanism and make any necessary adjustmentsDrain, flush and refill the generator cooling systems every two years, beginning December 2019.Air filters need to be changed out every 3 years Oil and fuel filters need to be changed out once a year Check operation of fuel transfer pumps and day tank systemsTake engine oil sample and have analysis performed. Provide copy of the report to the facility. The contractor shall make all adjustments and repairs where parts are not required. The contractor shall provide a list of parts required by part number, manufacturer and a source where parts can be purchased.The contractor shall provide a written report to the Maintenance Supervisor (COR) within 30 days after completion of the inspection. The report will contain information as to the condition, operation, recommendations for corrective action; and analysis report of engine oil sample. Written reporting shall contain but not limited to the following headings:Lubricating SystemCooling Systems and HosesAir Cooled EnginesFuel SystemAir Intake SystemExhaust SystemIgnition System (Gas/Gasoline) also provide fuel analysis on each generator.Engine Electrical SystemEngine Generator SystemGenerator OperationTransfer Switch OperationGenerator InspectionGenerator Room/EnclosureAssessment of Evidence of Wet StackingThe contractor shall provide the Contracting Officer s Representative (COR) notification five (5) working days prior to coming onto the site for inspection.V. CONTRACTOR QUALIFICATIONSContractor shall have a minimum five (5) years of experience servicing generators for various types of facilities. Contractor shall have a minimum five (5) years of experience servicing the type of generators indicated in section III Equipment Description above. Contractor shall have Liability Insurance. VI. SECURITY REQUIREMENTS:Contractor must report to Building 14, Utilities and Maintenance Supervisor to get access badge starting at 8:00 a.m. and may be accompanied by a VA employee while on station at the COR s discretion. Contractor must report to Building 13, Utilities Supervisor.Vendors/contractors shall wear VA issued ID badge at all times while on station. Taking photographs and video is strictly prohibited while on station and on all Federal VA premises. SITE VISIT: Bidders shall visit the site to confirm location, dimension, and condition of the required for the fulfillment of this contract. The site visit shall be for the purpose of observing first hand any conditions relevant to the fulfillment of this contract. No consideration will be given to claims based on a lack of knowledge of the existing conditions, except where contract documents make definite provisions for adjustment in cost or extension due to existing conditions not readily foreseeable. One (1) site visit will be held on December 16, 2019 at 10:00 am CST. The site visit address is:CAVHCS 2400 Hospital Road Building 68, Room 217Tuskegee, AL 36083There are two locations (Tuskegee and Montgomery) for the site visit, the government will not provide transportation. The meeting will start at the above address mention in Tuskegee AL. Questions and Answers: All questions and answers must be in writing. Email all questions to earnest.ellison@va.gov and courtesy copy Yolanda.Bickham@va.gov. Do not contact the Contracting Officer Representative (COR) this will delay a response to RFIs. RFI time period ends 12/23/2019 at 9:30 pm cst. Incidental Parts and Repairs The contractor shall provide all labor, equipment, tools material, supervision, test equipment, travel and transportation necessary to perform repairs of the Diesel Generators located in Montgomery and Tuskegee Al, all modifications must be approved by the Contracting Officer prior executing repairs. The contractor shall submit one quote for the repairs to the COR and Contracting Officer.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/46ef3fc6882c411ca3a370542777f418/view)
 
Record
SN05513924-F 20191213/191211230304 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.