Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 21, 2019 SAM #6596
SOURCES SOUGHT

Y -- Building E3330 Repairs

Notice Date
12/19/2019 10:29:13 AM
 
Notice Type
Sources Sought
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
W2SD ENDIST BALTIMORE BALTIMORE MD 21201 USA
 
ZIP Code
21201
 
Solicitation Number
W912DR20R0012
 
Response Due
1/16/2020 8:00:00 AM
 
Archive Date
02/29/2020
 
Point of Contact
Michael J. Getz, Phone: 4109623455
 
E-Mail Address
Michael.J.Getz@usace.army.mil
(Michael.J.Getz@usace.army.mil)
 
Description
TITLE: REPAIR BUILDING E3330, LAB & TEST, COMBAT CAPABILITIES DEVELOPMENT COMMAND � CHEMICAL BIOLOGICAL CENTER, ABERDEEN PROVING GROUND, EDGEWOOD, MD SOLICITATION NO. W912DR20R0012 THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR PROPOSALS, QUOTATIONS OR BIDS. THERE WILL NOT BE A SOLICITATION, SPECIFICATIONS, OR DRAWINGS AVAILABLE AT THIS TIME.� � � � � � � � � � � � � � � � � � � �� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � The U.S. Army Corps of Engineers (USACE), Baltimore District, requests letters of interest from qualified SMALL BUSINESS CONSTRUCTION CONTRACTORS interested in performing work on the potential construction project for Repair of Building E3330, Lab & Test, Chemical Biological Center at Aberdeen Proving Ground Edgewood Area. By way of this Market Survey/Sources Sought Notice, the USACE Baltimore District intends to determine the extent of capable firms that are engaged in providing the services described hereunder. Responses to this Sources Sought announcement will be used by the Government to make appropriate acquisition decisions. Responses to this notice are not offers and cannot be accepted by the U.S. Government to form a binding contract. It is the responsibility of the interested parties to monitor this site for additional information pertaining to this notice. PROJECT DESCRIPTION: The project is for the restoration and modernization of historic building E3330 to support the U.S. Combat Capabilities Development Command Chemical Biological Center (CCDC CBC), Aberdeen Proving Ground Edgewood Area, Edgewood, Maryland.� The Repair Building E3330 Lab & Test project is for the complete restoration and modernization of the approximately 175,000 square foot building.� The project will address structural deterioration; removal and replacement of building utility systems including:� Heating, Ventilation, and Air Conditioning (HVAC) systems, plumbing systems, electrical systems, fire suppression and alarm/mass notification systems, utility management control, telephone, advance communication networks, cable television and infrastructure for and installation of complete electronic security systems (ESS) (i.e. intrusion detection, closed-circuit surveillance and electronic access control), replacement of a service elevator, ADA access points, and ADA compliant elevators. New interior spaces will be created which include offices, open office areas, conference rooms, break rooms, restrooms, chemical test and laboratory, biological test and laboratory, secured space requirement per ICD-705, utility support space, secure historical documents library. �New interior finishes will be provided throughout the building.� Repair and replace building windows.� Repair and/or install new exterior finish system.� Exterior site-work and utilities include repairing draining problems to eliminate ponding along the foundation of the building, a new underground fire water main and post indicator valve, electrical, water, gas, sanitary sewer and information systems distribution, utility screening.� The construction contract will also include separate packages for the procurement and installation of furniture, furnishings and industrial/manufacturing type equipment, IT/communications and for electronic surveillance systems (ESS).� Work will consist of Hazardous Material abatement and demolition to address water infiltration and condensation from improper Heating, Ventilation, and Air Conditioning that have led to mold in numerous areas of the building, asbestos tile from the original construction in 1941, and lead based paint.� Portions of the building, including the main entry lobby, are considered historic and require State Historic Preservation Office coordination.� The purpose of this notice is to gain knowledge of interest, capabilities and qualifications of various members of industry, to include the Large Business and Small Business Community: Small Business (SB), Section 8(a), Historically Underutilized Business Zones (HUBZones), Small Disadvantaged Business (SDB), Veteran-Owned Small Business (VOSB), Service-Disabled Veteran-Owned Small Business (SDVOSB), and Women-Owned Small Business (WOSB). ACQUISITION APPROACH: The Government is anticipating a Two-Phase Design-Build Request for Proposal best value trade-off procurement process.� CONSTRUCTION MAGNITUDE: In accordance with DRARS 236.204 the magnitude of construction is between $25,000,000 and $100,000,000. RESPONSES TO THIS NOTICE: Responders should address ALL of the following in their submittal: Firm�s name, address, point of contact, phone number, email address, CAGE code and DUNS number. Indicate if your company is currently registered with the Systems for Award Management (SAM) database.� If not, indicate if it has been registered or does it plan to register. In consideration of NAICS code 236220, with a small business size standard in dollars of $39.5M, indicate which of the following small business categories your business is classified under:� Small Business, Veteran Owned Small Business, Service Disabled Veteran Owned Small Business, Small Disadvantaged Business, Woman-Owned Small Business, HUBZone Small Business, or 8(a) Business. Indicate if your company is currently prohibited from doing business from doing business with the Federal Government.� Yes/No. (If yes, explain). Provide a letter from the surety regarding the bonding capability for a single contract action and aggregate of the interested prime contractor. Provide at least three (3) example projects similar to the project description above completed by the interested prime contractor in the last ten years.� Projects shall be no less than $50M.� Include point of contact information for the examples provided in order for the Government to verify the past performance on indicated projects.� Contractors with unsatisfactory past performance may not be considered capable of successfully performing this type of work. Responders should have experience in the area listed below and provide narrative identifying that specific experience:� Antiterrorism Force Protection (ATFP) Compliance; United Facilities Criteria (UFC); Department of the Army Information Security Program specifically Sensitive Compartmented Information and Special Access Program Information; Chemical and Biological test and laboratory spaces; hazardous material abatement and demolition; Americans with Disabilities Act. Total submittal shall be no longer than 20 pages in one (1).pdf file double sided pages will count as two (2) separate pages. Comments will be shared with the Government project team, but otherwise will be held in strict confidence. SUBMISSION INSTRUCTIONS: THIS NOTICE IS NOT A REQUEST FOR PROPOSAL, QUOTE OR BID. It is a market research tool being utilized to determine the availability of potential qualified contractors before determining the method of acquisition. In addition, this sources sought is not to be considered as a commitment by the Government, nor will the Government pay for any information solicited or delivered. Interested parties who consider themselves qualified to perform the above-listed requirement are invited to submit a response to this Sources Sought Notice NLT 11:00 AM (EST) 16 January 2020. All responses under this Sources Sought Notice must be emailed to michael.j.getz@usace.army.mil, Contract Specialist, referencing the sources sought notice number W912DR20R0012. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. If you have any questions concerning this opportunity please contact: Michael Getz via email � michael.j.getz@usace.army.mil.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/c8247b2a9c3741a6bc58aa2a5dde56c3/view)
 
Place of Performance
Address: Aberdeen Proving Ground, MD 21040, USA
Zip Code: 21040
Country: USA
 
Record
SN05521910-F 20191221/191219230156 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.