Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JULY 01, 2020 SAM #6789
SOLICITATION NOTICE

W -- Rental of Mobile Pharmacy Trailer

Notice Date
6/29/2020 7:42:29 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
532120 — Truck, Utility Trailer, and RV (Recreational Vehicle) Rental and Leasing
 
Contracting Office
262-NETWORK CONTRACT OFFICE 22L (36C262) LONG BEACH CA 90815 USA
 
ZIP Code
90815
 
Solicitation Number
36C26220Q0964
 
Response Due
7/1/2020 9:00:00 AM
 
Archive Date
07/06/2020
 
Point of Contact
adrienne.brown4@va.gov, Adrienne Brown, Phone: 951-601-4536
 
E-Mail Address
Adrienne.Brown4@va.gov
(Adrienne.Brown4@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
The purpose of this amendment is to: Extend the response date to July 1, 2020 at 0900 PST Answer questions submitted by potential offeror See question and answers below. Questions Q: There shall be pass throughs equipped with a HEPA filtration air purge between the workroom and the hazardous and non-hazardous buffer rooms. The current pass through on the non-hazardous side is static not HEPA because the room is positive pressure. The current design meets the requirements of USP 797/800. Is static configuration in the non-hazardous side acceptable?   A: Yes, if requirements of USP 797/800 are met. Q: Power a. The contractor shall provide a step-down transformer for the Government provided power b. Contractor shall provide all necessary cabling to hook up the trailer and any necessary ADA cable ramps. Does the current trailer have an ADA cable ramp installed? A: VA is currently using its own 3-foot-long cable ramp. Q: Task 4: Non-Hazardous and Hazardous Anteroom Capabilities/Requirements a. Filtration: ISO Class 7 b. Pressurization: Positive pressure with minimum 30 ACPH c. Minimum size/space: 4 x 4 x 7 H (ceiling) d. Contain casework for personal protective equipment (PPE) that must be donned by staff prior to entering the respective hazardous and nonhazardous IV preparation rooms e. Contain a bench for staff to sit while donning/doffing PPE The current non-hazardous anteroom is designed to ISO-8 which meets USP 797/800. Does this the non-hazardous anteroom have to be brought up to ISO-7? A: No, ISO Class 8 would be fine for the non-hazardous ante room. The hazardous ante room, however, will need to be ISO Class 7.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/054f6d334cd946cb937fdfa3f5d0a9cc/view)
 
Place of Performance
Address: Department of Veteran Affairs VA Loma Linda Healthcare System 11201 Benton Street Bldg 1C05, Loma Linda 92357, USA
Zip Code: 92357
Country: USA
 
Record
SN05706254-F 20200701/200629230154 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.