SOLICITATION NOTICE
W -- Rental of Mobile Pharmacy Trailer
- Notice Date
- 6/29/2020 7:42:29 AM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 532120
— Truck, Utility Trailer, and RV (Recreational Vehicle) Rental and Leasing
- Contracting Office
- 262-NETWORK CONTRACT OFFICE 22L (36C262) LONG BEACH CA 90815 USA
- ZIP Code
- 90815
- Solicitation Number
- 36C26220Q0964
- Response Due
- 7/1/2020 9:00:00 AM
- Archive Date
- 07/06/2020
- Point of Contact
- adrienne.brown4@va.gov, Adrienne Brown, Phone: 951-601-4536
- E-Mail Address
-
Adrienne.Brown4@va.gov
(Adrienne.Brown4@va.gov)
- Small Business Set-Aside
- SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Awardee
- null
- Description
- The purpose of this amendment is to: Extend the response date to July 1, 2020 at 0900 PST Answer questions submitted by potential offeror See question and answers below. Questions Q: There shall be pass throughs equipped with a HEPA filtration air purge between the workroom and the hazardous and non-hazardous buffer rooms. The current pass through on the non-hazardous side is static not HEPA because the room is positive pressure. The current design meets the requirements of USP 797/800. Is static configuration in the non-hazardous side acceptable? A: Yes, if requirements of USP 797/800 are met. Q: Power a. The contractor shall provide a step-down transformer for the Government provided power b. Contractor shall provide all necessary cabling to hook up the trailer and any necessary ADA cable ramps. Does the current trailer have an ADA cable ramp installed? A: VA is currently using its own 3-foot-long cable ramp. Q: Task 4: Non-Hazardous and Hazardous Anteroom Capabilities/Requirements a. Filtration: ISO Class 7 b. Pressurization: Positive pressure with minimum 30 ACPH c. Minimum size/space: 4 x 4 x 7 H (ceiling) d. Contain casework for personal protective equipment (PPE) that must be donned by staff prior to entering the respective hazardous and nonhazardous IV preparation rooms e. Contain a bench for staff to sit while donning/doffing PPE The current non-hazardous anteroom is designed to ISO-8 which meets USP 797/800. Does this the non-hazardous anteroom have to be brought up to ISO-7? A: No, ISO Class 8 would be fine for the non-hazardous ante room. The hazardous ante room, however, will need to be ISO Class 7.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/054f6d334cd946cb937fdfa3f5d0a9cc/view)
- Place of Performance
- Address: Department of Veteran Affairs VA Loma Linda Healthcare System 11201 Benton Street Bldg 1C05, Loma Linda 92357, USA
- Zip Code: 92357
- Country: USA
- Zip Code: 92357
- Record
- SN05706254-F 20200701/200629230154 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |