Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JULY 23, 2020 SAM #6811
SPECIAL NOTICE

99 -- TECHNOLOGY/BUSINESS OPPORTUNITY Livermore Tomography Tools (LTT)

Notice Date
7/21/2020 5:17:29 PM
 
Notice Type
Special Notice
 
Contracting Office
LLNS � DOE CONTRACTOR Livermore CA 94551 USA
 
ZIP Code
94551
 
Solicitation Number
FBO465-20
 
Response Due
8/20/2020 9:00:00 PM
 
Archive Date
08/22/2020
 
Point of Contact
Connie Pitcock, Phone: 9254221072, Charity Follett, Phone: 9254221817
 
E-Mail Address
pitcock1@llnl.gov, follett2@llnl.gov
(pitcock1@llnl.gov, follett2@llnl.gov)
 
Description
Opportunity: Lawrence Livermore National Laboratory (LLNL), operated by the Lawrence Livermore National Security (LLNS), LLC under contract no. DE-AC52-07NA27344 (Contract 44) with the U.S. Department of Energy (DOE), is offering the opportunity to license and commercialize LLNL�s Livermore Tomography Tools (LTT). Challenge: Computed Tomography (CT) is a common imaging modality used in industrial, healthcare, and security settings. It is widely used at LLNL for non-destructive evaluation using all manner of waves and particles (e.g., x-rays, neutrons, protons). During a common CT scan, a beam of x-rays is passed through an object (whether a person, airport luggage or industrial part), recorded from many angles on a detector, then processed by a computer to generate 2D cross-sectional images or tomographic slices of the object. A number of these tomographic image slices are then digitally stacked together to form a full 3D volume of the object�s interior. Many types of CT reconstruction and analysis software methods have been implemented since its invention in the early 1960�s. However, most are specific to a single scanner setup, require hardware-based knowledge, and are susceptible to a number of artifact-causing problems such as scatter, metal shadowing, detector blur, and beam hardening. Frequently, the specialized algorithms needed to correct these issues take much more time to process and/or may not significantly improve the image. The resulting images typically contain qualitative pixel values with little physical meaning, not quantitative 3D features such as density or atomic number. Consequently, this type of CT scanning is not as helpful for applications that require physics-based measurements or high throughput (i.e., industrial non-destructive evaluation or cargo screening) or low doses (medical). These deficiencies limit industry adoption. CT performance improvement is essential as the need increases for more challenging 3D imaging problems with different materials in various sizes. Description:� To solve these challenges using new and existing CT system designs, LLNL has developed an innovative software package for CT data processing and reconstruction. Livermore Tomography Tools (LTT) is a modern integrated software package that includes all aspects of CT modeling, simulation, reconstruction, and analysis algorithms based on the latest research in the field. LTT contains the most expansive and recently published CT data preprocessing and reconstruction algorithms available. LTT is platform-independent (Windows, Linux, and Mac) and capable of processing data on one or more graphical processing units (GPUs) or other hardware accelerators, including high-performance supercomputers. It can be used as a stand-alone application, accessed as a library from existing applications such as MATLAB or Python, or integrated into a separate graphical user interface (GUI) that the user may require. The algorithms in LTT are capable of processing CT data from raw detector counts to recon�structed volumes and are designed to provide quantitatively accurate results (with specified units) in a timely manner. Most conventional scanner geometries (parallel-, fan-, and axial/helical cone-beam) are supported, as well as modern fixed gantry systems in which the user provides the location of every x-ray source and detector pair and the detector orientation in a text file. With x-ray and neutron cross-section tables included, LTT is the right tool to research the best CT scanner and experimental designs based on physics models. It incorporates algorithms to correct for beam hardening, scatter, blur, and other common issues of CT data acquisition. LTT implements advanced iterative reconstruction algorithms to build 3D volumes of an object in cases where the data are incomplete, such as limited view, sparse view, high aspect-ratio objects, or metal obscuration. This versatility greatly enhances LTT�s usability and provides a means to simultaneously process, reconstruct, and analyze CT data and volumes. Advantages LTT�s primary benefits are: Reduced Processing Time: �Automatically optimizes for the full capabilities of many computer system architectures including multiple nodes and multiple GPUs (NVIDIA, AMD, or Intel); Accuracy: Provides quantitatively accurate results independent of the CT scanning system; Flexibility: Processes data from any CT geometry and runs on Windows, Mac, and Linux platforms. Potential Applications LTT is a highly efficient and versatile research tool for CT. By reducing the time needed to properly reconstruct a 3D image of a scanned item, LTT can increase throughput and reduce image processing labor costs for applications such as industrial quality control scanning and airport baggage screening. LTT provides quantitively accurate results independent of the system, and its flexibility allows data to be processed from any CT geometry, independent of the computing platform, making it suitable for many industrial applications. If approved and used for medical diagnostics applications, LTT has the potential to significantly reduce the number of projections required�which reduces both the scan time and the patients� exposure to radiation. And by reducing the time needed to properly reconstruct a 3D volume, LTT could increase throughput for CT medical screening�which further reduces the operational costs and time demands on healthcare providers. Development Status:� LLNL has filed for patent protection and has copyrights on the LTT software.� LTT is at the TRL of 7-9. NOTE:� THIS IS NOT A PROCUREMENT. Partnership Criteria LLNL is seeking interested end user licensees as well as U.S. industry partners interested in commercializing and distributing the software. Distribution partners should show their demonstrated ability to work with Federal Laboratories and bring Laboratory innovations to the market. Interested End Users Interested end users may request a license by emailing follett2@llnl.gov. Licenses are negotiable depending on the type of organization and use case requested. To help the nation address the serious challenge that the COVID-19 pandemic represents, LLNL is also making LTT available under a special, royalty-free, non-exclusive license. Qualified users who will use LTT for the purpose of researching, developing and utilizing solutions to respond to and mitigate the effects of COVID-19 can obtain a non-negotiable license via the agreement posted at https://ipo.llnl.gov/coronavirus. Interested Commercialization Partners Companies interested in commercializing and distributing LTT are invited to respond to this announcement. Please visit the IPO website at https://ipo.llnl.gov/resources for more information on working with LLNL and the industrial partnering and technology transfer process. Companies with demonstrated experience and expertise commensurate with the commercialization efforts needed should provide a detailed statement of interest no later than sixty (60) days from the publication date of this notice. The statement of interest should describe the following company elements: Organization name and address The name, address, and telephone number of a point of contact Related experience, expertise and complimentary technologies Demonstrated ability to bring innovations to the market Sufficient resources to accomplish development and commercialization of the system Interest in performing and/or funding cooperative research at the LLNL Relevance for LLNL mission and economic development interest Substantial presence in the United States. Note: LLNL�s technology is export controlled and LLNL prefers to work with U.S. organization(s). Responses should reference FBO 465-20 and be directed to follett2@llnl.gov. Please provide your statement within sixty (60) days from the date this announcement is published to ensure consideration of your interest in LLNL's Livermore Tomography Tools (LTT).
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/4daa2b69cf5647658322f1669d5bd5e0/view)
 
Record
SN05727354-F 20200723/200721230147 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.