65 -- Phillips Allura Xper FD10 repair St. Louis VAMC

Notice Date
7/31/2020 12:29:54 PM
 
Notice Type
Special Notice
 
NAICS
334517 — Irradiation Apparatus Manufacturing
 
Contracting Office
255-NETWORK CONTRACT OFFICE 15 (36C255) LEAVENWORTH KS 66048 USA
 
ZIP Code
66048
 
Solicitation Number
36C25520F0200
 
Archive Date
08/30/2020
 
Point of Contact
Jeanine Wallace, Contracting Officer, Phone: 913-946-1968
 
E-Mail Address
jeanine.wallace@va.gov
(jeanine.wallace@va.gov)
 
Awardee
null
 
Description
B.3 STATEMENT OF WORK: General Information Service Agreement: The St. Louis VA Medical Center is requesting to establish an emergency service contract for the repair on the Philips Allura Xper FD10. The facility is located at: VA St. Louis Healthcare System John Cochran Division 915 N. Grand Blvd. St. Louis, MO 63106 Scope of Work: The Contractor shall supply all labor, travel, materials, equipment, tools, supervision, and all incidentals required to complete on-site full diagnosis and repair of the equipment identified in Section II, in accordance with Manufacturer s recommendations, Joint Commission standards, design specifications, and the specifications, terms, and conditions of this contract. Performance Period: The Contractor shall begin the work required under this SOW commencing with the effective date of award, unless otherwise directed by the CO, and shall provide continuous service until the X-ray system is fully operational. Equipment to be Serviced Each of the following items is to be serviced in accordance with the specifications, terms and conditions of this contract. Line Item Manufacturer Model EE# Location 1 Philips Allura Xper FD10 142853 B516-01-JC Services to be Provided The Contractor shall supply all labor, travel, materials, equipment, tools, supervision, and all incidentals required to complete on-site full diagnosis and repair. Currently, the X-Ray is down and needs a new tube to be replaced. Documentation/Reports No later than seven (7) business days after the conclusion of any maintenance or repair the Contractor will provide to the COR or Alt COR a signed detailed service/inspection report listing all devices, all repairs for each device, parts used to maintain or repair the devices, and operating efficiency of the devices. The service/inspection report shall contain, at a minimum, the following information: Date and time of the technician s arrival on station. Type, model, and serial number(s) of all equipment on which maintenance was performed. Total time spent performing maintenance (exclusive of any travel time). Detailed narrative description of work performed. Complete list of parts replaced. Comments as to the cause of the malfunction when applicable Date and time the repair/preventive maintenance was completed. Security Requirements Upon arrival at the VA Medical Center, all Contractor personnel shall be required to report to the VA Medical Center Police for a temporary ID and then to the COR for check-in. This check-in process is mandatory. When the service is completed, the personnel shall be required to check out with the COR, Biomedical Engineering Shop Supervisor. The contractor's field service employee shall wear visible identification at all times while on the premises of the VA Medical Center. Competency of Contractor Personnel The Contractor must have an established business, with an office and full time staff. The staff includes a ""fully qualified"" FSE and a ""fully qualified"" FSE who will serve as the backup. Fully Qualified"" is based upon training and experience in the field. For training, the FSE(s) must have successfully completed a formal OEM Certified (or equivalent) training program for all equipment to be maintained and all equipment to be utilized in the performance of the contract. For field experience, the FSE(s) must have a minimum of two years of experience in the installation, calibration, maintenance and repair of the specific equipment identified in Section II. All work shall be performed by ""Fully Qualified"" competent FSEs. The Contractor shall provide written assurance of the competency of their personnel and a list of credentials of approved FSEs. The CO may authenticate the training requirements by request training certificates or credentials from the Contractor at any time for any personnel who are providing services. The CO and/or the COR or Alt COR specifically reserve the right to reject any of the Contractor's personnel and refuse them permission to work on equipment. If subcontractor(s) are used, they must meet the same competency standards as Contractor personnel and be preapproved by the CO. The Contractor shall submit any proposed change in subcontractor(s) to the CO for approval or disapproval. Exposure to Blood Borne or Infectious Material There is a potential for exposure to blood borne or other infectious material with equipment throughout the medical centers. All maintenance persons must use the Universal Precautions (i.e. decontamination of medical equipment, wearing protective gloves, aprons, and goggles) during cleaning and maintenance/repair procedures. Test Equipment The Contractor shall provide the COR or Alt COR with a copy of the current calibration certification of all test equipment which is to be used by the Contractor in the performance of this contract. Test equipment calibration shall be traceable to a national standard. Identification, Parking, Smoking, and VA Regulations Contractor s personnel shall wear visible identification at all times while on the premises of the VA. Identification shall include, as a minimum, the employee s name, position, and the contractor s trade name. It is the responsibility of the contractor to park in the appropriate designated parking areas. Information on parking is available from VA Police Service. VA will not invalidate or make reimbursement for parking violations of the contractor under any conditions. Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search. Violations of VA regulations may result in citation answerable in the United States (Federal) District Court, not local district, state, or municipal court. Smoking is prohibited inside all VA buildings. Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search. Violations of VA regulations may result in citation answerable in the United States (Federal) District Court, not a local district, state or municipal court. IT Security Requirements VA information technology certification and accreditation requirements do not apply to this contract and a security accreditation package is not required.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/e67f4624b3444d2bbdb9d87f0d8fb310/view)
 
Record
SN05741385-F 20200802/200731230144 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.