Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF AUGUST 29, 2020 SAM #6848
SOLICITATION NOTICE

Y -- Repair Fire Suppression Systems in Bldgs 323, 431, 441 and 443

Notice Date
8/27/2020 2:17:19 PM
 
Notice Type
Solicitation
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
US ARMY ENGINEER DISTRICT FT WORTH FORT WORTH TX 76102-6124 USA
 
ZIP Code
76102-6124
 
Solicitation Number
W9126G20B0032
 
Response Due
9/11/2020 8:00:00 AM
 
Archive Date
09/26/2020
 
Point of Contact
Markeith Berry, Phone: 8178861269, Eugene A. Gibbs, Phone: 8178861069
 
E-Mail Address
markeith.berry@usace.army.mil, Eugene.a.gibbs@usace.army.mil
(markeith.berry@usace.army.mil, Eugene.a.gibbs@usace.army.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
**AMENDMENT 0002�FOR THIS SOLICITATION IS HEREBY POSTED AND ISSUED AS OF THURSDAY, 27�AUG 2020** Location: Red River Army Depot, Texarkana, TX: �Total Small Business Set Aside Invitation for Bid (IFB) This project is to repair/replace the Fire Suppression Systems in Buildings 323, 431, 441, and 443 at the Red River Army Depot (RRAD), Texarkana, Texas. Work shall include but is not necessarily limited to the following: Magnitude of Construction is between $1,000,000 and $5,000,000. Location 1 - This project is for the replacement of the Fire Suppression Systems in B323 at the RRAD, Texarkana, Texas. Work shall include but is not necessarily limited to the following: 1) Replacement of Fire Suppression System in Building 323. 2) Fire pump required as part of the design.� 3) Replacement shall include PI valve (and any work required to replace the PI valve), include all pipe, components, installation and painting. Fire Suppression System piping (above ground) shall be appropriately primed and painted red (no 11105, Safety Red) in accordance with MIL-STD-101 and ASME (ANSI) A13.1 codes when visible, but when the pipe would not be typically visible it may be appropriately marked/banded. The complete system shall be painted or marked/banded as indicated above. Location 2 - This project is for the replacement of the Fire Suppression Systems in B431 at the RRAD, Texarkana, Texas. Work shall include but is not necessarily limited to the following: 1) Replacement of Fire Suppression System in Building 431. 2) Fire pump is not required but a riser room shall be added to the building. 3) New drop ceiling is required. 4) Replacement shall include Post Indicator (PI) valve (and any work required to replace the PI valve). Fire Suppression System piping (above ground) shall be appropriately primed and painted red (no 11105, Safety Red) in accordance with MIL-STD-101 and ASME (ANSI) A13.1 codes when visible, but when the pipe would not be typically visible it may be appropriately marked/banded. The complete system shall be painted or marked/banded as indicated above. Location 3 - This project is for the replacement of the Fire Suppression Systems in B441 at the RRAD, Texarkana, Texas. Work shall include but is not necessarily limited to the following: 1) Replacement of Fire Suppression System in Building 441. 2) Fire pump is not required but a riser room shall be added to the building.� 3) Replacement shall include PI valve (and any work required to replace the PI valve). Fire Suppression System piping (above ground) shall be appropriately primed and painted red (no 11105, Safety Red) in accordance with MIL-STD-101 and ASME (ANSI) A13.1 codes when visible, but when the pipe would not be typically visible it may be appropriately marked/banded. The complete system shall be painted or marked/banded as indicated above. Location 4 - This project is for the replacement of the Fire Suppression Systems in B443 at the RRAD, Texarkana, Texas. Work shall include but is not necessarily limited to the following: 1) Replacement of Fire Suppression System in Building 443. 2) Fire pump and riser room are required.� 3) Replacement shall include PI valve (and any work required to replace the PI valve). Fire Suppression System piping (above ground) shall be appropriately primed and painted red (no 11105, Safety Red) in accordance with MIL-STD-101 and ASME (ANSI) A13.1 codes when visible, but when the pipe would not be typically visible it may be appropriately marked/banded. The complete system shall be painted or marked/banded as indicated above. Disclosure of the magnitude of construction project (ii) between $1,000,000. 00 to $5,000,000. 00 Anticipated project completion date is 365 days from Notice to proceed. After solicitation issuance, contractors may view and/or download this solicitation and all amendments at the following internet address: https://beta.sam.gov/.� The use of the website requires prior registration at https://beta.sam.gov/. Plans and specifications will not be made available at https://beta.sam.gov/ at issuance of solicitation.� It is the Offerors responsibility to monitor the https://beta.sam.gov/ web site for amendments to the solicitation.� You must be registered with the System Award for Management (SAM), to receive a Government contract award.�� The Government reserves the right to use only the Internet as notification of any amendments to this solicitation.� It is the offerors responsibility to view https://beta.sam.gov/. Website daily for amendments to the solicitation. Accordingly, prospective contractors may view and/or download the solicitation and all amendments from the https://beta.sam.gov/ website solicitation number W9126G20B0032.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/eff5ff25ee7b447e91205c580908ae1a/view)
 
Place of Performance
Address: Texarkana, TX 75507, USA
Zip Code: 75507
Country: USA
 
Record
SN05775977-F 20200829/200827230206 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.