Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JANUARY 07, 2021 SAM #6979
SOLICITATION NOTICE

Y -- Unit 1 & 2 Generator Stator Rewind

Notice Date
1/5/2021 11:25:54 AM
 
Notice Type
Solicitation
 
NAICS
237130 — Power and Communication Line and Related Structures Construction
 
Contracting Office
US ARMY ENGINEER DISTRICT TULSA TULSA OK 74137-4290 USA
 
ZIP Code
74137-4290
 
Solicitation Number
W912BV20R0040
 
Response Due
1/14/2021 12:00:00 PM
 
Archive Date
01/29/2021
 
Point of Contact
Shawn Brady, Phone: 9186697670, Julie S. Hill, Phone: 9186697699
 
E-Mail Address
shawn.brady@usace.army.mil, julie.s.hill@usace.army.mil
(shawn.brady@usace.army.mil, julie.s.hill@usace.army.mil)
 
Description
The Tulsa District Corps of Engineers has a requirement to perform all work required to rewind two approximately 50 MVA hydroelectric generating units at Keystone Powerhouse, Sand Springs, OK. The contractor shall furnish all labor, material, and equipment to perform this work in strict accordance with the detailed requirements of the specifications and associated drawings. The work described within these specifications shall include, but not necessarily be limited to, the following: 1. Design, manufacture, and perform Voltage Endurance test on prototype coils (or Roebel bars). 2. Perform Thermal Cycle test on prototype coils (or Roebel bars). 3. Design, manufacture, shop test, prepare and load for shipment, deliver f.o.b. destination, and unload two complete sets of stator coils (or Roebel bars) and specified accessories. 4. Pre-disassembly mechanical and electrical testing, and alignment checks of two hydroelectric generating units. 5. Disassemble two generator units, including the exciter equipment, air housing, and rotor. 6. Remove old stator coils, install and test new stator windings and accessories. 7. Clean, inspect, and test stator iron; perform necessary repairs to stator iron. 8. Furnish and Install new surge rings, circuit rings, main leads, and neutral leads. 9. Refurbish (machine) the collector rings. 10. Clean and inspect rotor, clean and test the rotor field poles winding. 11. Furnish spare parts. 12. Perform generator special field tests. 13. Furnish manufacturer�s representative on-site services to supervise installation of the generator stator coils (or Roebel bars), reassembly, and to perform start-up, commissioning, and testing of two generators. 14. Perform all work required for painting, miscellaneous welding, machinist, electrician, and other skilled craftsman hire.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/c826497d8e6644f1900bf47cc7f4605e/view)
 
Place of Performance
Address: Sand Springs, OK 74063, USA
Zip Code: 74063
Country: USA
 
Record
SN05884999-F 20210107/210105230110 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.