Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JANUARY 09, 2021 SAM #6981
SOURCES SOUGHT

65 -- Snowden Pencer laparoscopic instruments

Notice Date
1/7/2021 10:42:53 AM
 
Notice Type
Sources Sought
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
255-NETWORK CONTRACT OFFICE 15 (36C255) LEAVENWORTH KS 66048 USA
 
ZIP Code
66048
 
Solicitation Number
36C25521Q0124
 
Response Due
1/12/2021 1:00:00 PM
 
Archive Date
01/27/2021
 
Point of Contact
Jon LutmerJonathan.lutmer@va.gov 410-446-3862, Phone: 410-446-3862
 
E-Mail Address
Jonathan.lutmer@va.gov
(Jonathan.lutmer@va.gov)
 
Description
General Description of Performance Requirements and Features of the System: Laparoscopic ergonomic take-apart instruments. The instruments need to have the ability to be taken apart, separating the handle, shaft and insert to aid visual inspection during cleaning. �Contain a 360� rotation knob that is effectively sized and contoured to enable easy instrument rotation. Must have thumb actuation ridges to facilitate actuating the instrument using the thumb. Gripping flares to facilitate palm-grip applications. Integrated ratchet and ratchet defeat mechanism positioned to give fingertip access.� Large double front ring to help improve stability with removable cushioned insert which will aid to reduce thumb pressure and accommodate both larger and smaller hands.� Ergonomic contouring to uniformly distribute pressure on hands, decreasing the potential for intraoperative hand fatigue. Ring handle design to work with both a traditional precision grip or palm grip. Ratchet function mechanism should allow easy and quick adjustment. The same instrument should be able to be used with or without the ratchet function. Instruments should feature a tungsten-carbide insert where appropriate to ensure durable performance, but contain the capability of disassembly, separating the handle, shaft and insert to aid visual inspection during cleaning. Double-layer Halar� insulation to reduce the potential for cracks and defects in the shaft insulation. Dual assembly/release buttons to aid assembly and help eliminate unintended disengagement during use. Electrosurgical post to allow monopolar cutting and coagulation. Fully insulated durable polymer handle to protect against aggressive cleaning and sterilization. Validated to be reprocessed by both manual cleaning methods and automatic washer/disinfector. Validated to be sterilized containerized via prevacuum steam sterilization at a temperature of 270 degrees Fahrenheit with exposure time of at least 4 minutes. Site Specific Requirements:� Overall diameter of shaft will be both 5mm and 10mm where indicated Overall length of shaft will be 36mm or 45mm where indicated Jaws will be double action or single action where indicated Overall length of inserts will be 36mm or 45mm where indicated 10ea GRASPER, BULLET NOSE, DOUBLE ACTION INSERT 5MM-360MM 5ea DISSECTOR, DOUBLE ACTION, RIGHT ANGLE, SP,ERG TA 5MM-360MM 5ea DISSECTOR,INSERT,MARYLAND,SP,ERG TA,DOUBLE ACTION,ESU 5MM-360MM 10ea GRASPER,WAVY DOUBLE-ACTION,ERG TA,5MM-360MM,21.3MM JAW 5ea MCKERNAN FUNDUS GRASPER, SP, ERG TA5MM, 36CM, DOUBLE ACTION INSERT ESU 5ea ELECTRODE,ENDO,LAPAROSCOPY,COAGULATING,RIGHT ANGLE,33 CM 5ea DISSECTOR,SERRATED CUP,SP,ERG,TA,10MM-360MM 8ea HANDLE,NON-RATCHETED,V-MUELLER LAT-H-NR 10ea SHAFT,VM,TA,10MM-360MM 30ea DISSECTOR,SURGICAL,SNOWDEN-SPENCER,SHAFT,LENGTH 36 CM,RETRACTOR END 5 MM WIDE,HALAR COATED,TAKE APART 20ea DISSECTOR,SURGICAL,SNOWDEN-SPENCER,NON-RATCHET HANDLE,TUNGSTEN-CARBIDE INSERT,TA 20ea RATCHET/RATCHET DEFEAT HANDLE, ESU,HANDLE RRD 5ea CORD,BOVIE,UNIPOLAR,UNIVERSAL PLUG 4ea INSERT,DOUBLE ACTION,60 DEGREE ANGLED,ERG TA,10MM-450MM 6ea INSERT,DEBAKEY,DOUBLE ACTION,SP,ERG TA,ESU 5MM-450MM, 10MM,45CM,35MM JAW 4ea INSERT,DOUBLE ACTION,SERRATED CUP,SP,ERG TA,5MM-450MM 5ea HOLDER,NEEDLE,CURVED,LT,PISTOL GRIP,ERG TA,5MM-450MM 3ea GRASPER,DORSEY,FENESTRATED,DOUBLE ACTION INSERT,ESU 5MM-450MM 3ea DISSECTOR,LONG R ANGLE,DA 45CM,SP ERG TA,5MM,21.0MM JAW,DOUBLE ACTION INSERT 3ea GRASPER,BABCOCK,SP,ERT TA,10MM,45CM,DOUBLE ACTION STANDARD COMPLETE INSTRUMENT,ESU 10MM-450MM 3ea DISSECTOR,SERRATED CUP,SP,ERG TA,DOUBLE ACTION COMPLETE INSTRUMENT,NON-RATCHETED,5MM-450MM 2ea SHAFT 10MM 45CM HALAR COATED ESU 6ea RAPTOR 5MM 45CM SINGLE ACTION INSERT 16ea SHAFT 5MM 45CM HALAR COATED ESU �
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/6cd4e97efba8481f9fc5298a0a8cb1d3/view)
 
Place of Performance
Address: Wichita, KS 67218, USA
Zip Code: 67218
Country: USA
 
Record
SN05887643-F 20210109/210107230124 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.