SOLICITATION NOTICE
65 -- DriScope Jet Stream
- Notice Date
- 1/19/2021 1:24:29 PM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 257-NETWORK CONTRACT OFFICE 17 (36C257) ARLINGTON TX 76006 USA
- ZIP Code
- 76006
- Solicitation Number
- 36C25721Q0330
- Response Due
- 1/21/2021 1:00:00 PM
- Archive Date
- 01/31/2021
- Point of Contact
- Marcellus Jackson, Contract Specialist, Phone: 210-694-6376
- E-Mail Address
-
marcellus.jackson@va.gov
(marcellus.jackson@va.gov)
- Small Business Set-Aside
- SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Awardee
- null
- Description
- Statement of work DRI-SCOPE AID Jet Stream Endoscope Dryer 1. The CTVHCS -SPS currently owns endoscope drying cabinet that is built into the wall unit. The Austin SPS does not have space and due to design and building issues there is no way to install similar dying and storage cabinets. The Austin SPS will have to either retrofit current endoscope storage cabinets or use exterior drying technique to dry endoscopes prior to hanging in storage cabinet. The CTVHCS Austin Sterile Processing Service (SPS) needs to retrofit their cabinets with the capability to dry the interior lumens and passages of the endoscopes without adding additional cabinets. 2. These scope driers need to be approved for use on Olympus endoscopes and Karl Storz endoscopes. 3. The endoscope drier system needs to be 110V powered and produce own purified filtered medical grade air. 4. Reference for the requirements can be found in AAMI-ST91, AAMI ST79 and VHA Dir. 1116(2). 5. Salient requirements for CTVHCS AOPC SPS Endoscope drying Statement of Need: SPS has requirement to ensure all endoscopes have all lumens dried with filtered forced medical grade air to dry the inside of the flexible endoscopes. Austin SPS facility is not able to have cabinets replaced with a different unit due to size versus locations, power and medical air supply line requirements as well as remodeling would cause the procedure areas to be closed for several days. Endoscope drying system: 1. Must be compatible with Olympus America CF190 and GF 190 endoscopes and GFUC Endoscopes. Must also have kits to fit K. Storz endoscopes 2. Must produce own filtered medical grade air from room air. 3. Must function using 110V power. 4. Easily replaceable lines and filters 5. Wall mounted, small footprint necessary. 6. Affordable and available single use or 1-day use connectors. 7. Minimum 1- year warranty and on-site technical help and repair. Suggested vendor is Tricor for recommended product: Dri-Scope Aid Jet Stream Manufacturor/Description/Part/Model Number* Qty 402119-111-TS SI Mounting Bracket kit 6 402119-210 Air Filter (0.1µm) - replacement 6 402119-100P-T TSI Dri-Scope AidT Jet-Stream Series 1840P Kit (main part of system with filtered air pump and timer) 6 402119-101P-T TSI Dri-Scope AidT, Jet-Stream, Series 1040P 6 401789-146 Power Supply, Medical Grade (w/6' cord) 6 402119-167 Operator's Manual, Jet Stream, Series 1840P 6 402119-211 Pressure Test Load (w/log sheet) 6 402119-210 Air Filter (0.1µm) - installed 6 TD-662 Quick Start Guide 6 401789-405-2 Olympus Single-Use Connector-Type ""O"" (Qty 100) 1 401789-414 Olympus 24hr Tubing Kit-Type O (qty 10) 1 401789-411 Small Diameter 24hr Tubing Kit-Type SD-O(qty 10 ) 1 401789-412 Olympus Bronchoscope Single-Use Connector-Type SD-O(qty 100 ) 1 401789-413 Small Diameter Single-Use Connector-Type SD-U(qty 100 ) 1
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/dc27bccd213140aa956c232797a92655/view)
- Place of Performance
- Address: Olin E. Teague VAMC 1901 Veterans Memorial Dr., Temple, TX 76504, USA
- Zip Code: 76504
- Country: USA
- Zip Code: 76504
- Record
- SN05894874-F 20210121/210119230110 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |