SOURCES SOUGHT
J -- FY21 Scope Repair Service contract (VA-21-00028443)
- Notice Date
- 1/22/2021 1:47:08 PM
- Notice Type
- Sources Sought
- NAICS
- 811219
— Other Electronic and Precision Equipment Repair and Maintenance
- Contracting Office
- 242-NETWORK CONTRACT OFFICE 02 (36C242) ALBANY NY 12208 USA
- ZIP Code
- 12208
- Solicitation Number
- 36C24221Q0441
- Response Due
- 1/28/2021 8:00:00 AM
- Archive Date
- 01/28/2021
- Point of Contact
- Joseph R Cellino, Contract Specialist, Phone: 716-862-7895
- E-Mail Address
-
Joseph.Cellino@va.gov
(Joseph.Cellino@va.gov)
- Awardee
- null
- Description
- SOURCES SOUGHT NOTICE This is a SOURCES SOUGHT NOTICE only. This is not a request for formal proposals or quotes. No formal solicitation document exists at this time. This request is for planning purposes only and shall not be considered as an invitation for bid, request for quotation, request for proposal, or as an obligation on the part of the Government to acquire any products or services. Your response to this notice will be treated as information only. No entitlement to payment of direct or indirect costs or charges by the Government will arise as a result of contractor submission of responses to this announcement or the Government use of such information. PURPOSE AND OBJECTIVES: The intent of this notice is to identify capable sources interested in providing ENDOSCOPE REPAIR SERVICES for the Buffalo VA Medical Center located at 3495 Bailey Ave, Buffalo, NY 14215. The anticipated contract action is expected to be a Fixed-Price, Indefinite Delivery Vehicle. All responsible sources who believe they can furnish the service described in this notice may submit a capability statement clearly establishing an ability to provide the required service in the place of performance by emailing Joseph.Cellino@va.gov with details regarding your firm s capability no later than 11:00PM EST on January 28, 2021. Additionally, responses must specify whether loaners can be provided during repairs as well if the required turn-around time can be met. It is the responsibility of respondents to provide sufficient information. BRIEF DESCRIPTION OF REQUIREMENT: B.4.1 QUALIFICATIONS: All work to be performed by a qualified Field Service Engineer (FSE). A qualified FSE shall be defined as an individual who has successfully completed a formalized training program of the equipment the individual shall service and has a minimum of two years of experience with respect to scheduled and unscheduled preventive and remedial maintenance of the endoscopic instruments that individual shall service. Acceptable FSE training can be provided either by the original equipment manufacturer or through an internal training program. If the required training has been provided through an internal training program, the contractor shall provide documentation of the contents and format of their internal training program, so that a determination can be made whether it is acceptable. An acceptable training program shall be defined as an established ongoing training program that includes a formal method of evaluating a technician s competency/ proficiency and the individual(s) in charge of training shall be Original Equipment Manufacturer (OEM) certified on all endoscopes to be serviced. The Contractor shall provide written assurance to the competency of their personnel and a list of credentials of approved FSE(s) for each make and model the Contractor services at the VA. The Contracting Officer (CO) and/or Contracting Officer's Representative (COR) specifically reserves the right to reject any of the Contractor's personnel and refuse them permission to work on the VA equipment. B.4.2 SERVICES TO BE PROVIDED: B.4.2.1 REPAIRS All onsite visits shall be performed during the normal VA business hours (7:00 a.m. 4:30 p.m.) Monday through Friday, excluding Federal holidays, which shall be defined as New Year s Day, Martin Luther King Day, Presidents Day, Memorial Day, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day and Christmas Day. The Contractor shall be able to service all endoscopes listed in the attachment. All equipment being repaired shall be transported in appropriate protective containers or packaging that shall limit the possibility of damage to the scope while away from the hospital. Equipment shall be picked up and dropped off on site by contractor personnel, the use of third-party couriers is not acceptable. Acceptable transport containers shall be defined as the following: Pentax endoscopes shall be transported in the appropriate Pentax endoscope case based on the serial number of the Pentax endoscope. All other endoscopes, at a minimum the packaging for transport shall consist of a foam interior that tightly keeps the scope in place along with a hard exterior (at a minimum, cardboard). This packaging shall sufficiently protect the scope from any and all damage if it is accidentally dropped. The Contractor shall provide loaner equipment to the VA within 8 business hours of notification. The Contractor at no additional cost shall furnish a loaner of the same type of equipment to the Government as determined acceptable by VA clinicians. Loaned equipment shall be equal to or superior to equipment removed from the facility. Loaned equipment shall remain at the VA facility until repaired scope has been returned and the repair has been validated. Equipment shall be repaired to fully functional condition as soon as possible. In general, minor repairs should be completed within two (2) business days and major repairs should be completed within five (5) business days. All repairs shall be performed by qualified FSE. All completed repairs shall be verified by the Buffalo VA Medical Center biomedical Department prior to acceptance. The VA shall not provide service manuals or service diagnostic software to the Contractor. The Contractor shall obtain, have on file, and make available to its FSE(s), all operational and technical documentation (e.g., operational and service manuals, schematics, and parts lists) which are necessary to meet the performance requirements of this contract. The location and listing of the service data manuals, by name, and/or the manuals themselves shall be provided to the CO upon request. Any charges for parts, manuals, tools, or software required to successfully complete any service required shall be included within the scope of this task order and its agreed upon price. At the conclusion of each repair the Contractor shall provide a written service report indicating: Dates of service (including date received at the repair facility and date returned to the Government) Make, model, serial number, and barcode/ID number of the equipment serviced Name of FSE who performed the work Hours worked Description of the reported problem, and the services performed and parts replaced If the repair is caused by damage or abuse this shall be specified on the report including a justification for this determination At the end of each quarter the Contractor shall provide detailed history report of the repairs completed for that quarter. The contractor shall have an established formal quality control program implemented by OEM trained technician(s) for all of the endoscope models to be serviced to ensure repairs are done to OEM standards. B.4.2.2 PARTS The Contractor shall provide all replacement parts required to keep equipment performing within the Original Equipment Manufacturer (OEM) specifications. All parts shall meet or exceed manufacturer s factory specifications to maintain compatibility with systems presently in place and with future performance/reliability upgrades. Parts removed or replaced by the Contractor shall become property of the Contractor. The Contractor shall provide documentation with their quote that they shall only utilize parts/materials/components that are equal to or exceed OEM specifications, quality and performance standards. The parts/materials/components used shall not alter the effectiveness and validation sterilization/high level disinfection requirements in any way when the endoscope is reprocessed.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/5b19e9f7c71948e09527cacbafb89f44/view)
- Place of Performance
- Address: Buffalo VAMC 3495 Bailey Ave, Buffalo 14227
- Zip Code: 14227
- Zip Code: 14227
- Record
- SN05898206-F 20210124/210122230101 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |