Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JANUARY 27, 2021 SAM #6999
SOURCES SOUGHT

V -- Community Hoptel Service

Notice Date
1/25/2021 1:53:47 PM
 
Notice Type
Sources Sought
 
NAICS
721110 — Hotels (except Casino Hotels) and Motels
 
Contracting Office
249-NETWORK CONTRACT OFFICE 9 (36C249) MURFREESBORO TN 37129 USA
 
ZIP Code
37129
 
Solicitation Number
36C24921Q0109
 
Response Due
2/10/2021 9:00:00 AM
 
Archive Date
05/20/2021
 
Point of Contact
Michael Edwards, Contract Specialist, Phone: 615-225-5506
 
E-Mail Address
michael.edwards2@va.gov
(michael.edwards2@va.gov)
 
Awardee
null
 
Description
Page 4 of 9 This is a Request for Information Only; it is not a request for quotations or offers. CLASSIFICATION CODE: V231 Lodging Hotel/Motel NAICS CODE: 721110: Hotels Network-9 Contracting Office on the behalf of the James H. Quillen VA Medical Center, Corner of Lamont & Veterans Way, Mountain Home, Tennessee, has developed this Request for Information (RFI)/Sources Sought Notice to solicit market research information from industry to assist the Government with analysis of a Government requirement and provide commercial insight on performance-based solutions, best practices, possible contractual arrangements, and potential issues. This RFI is to determine the availability of Small Business (preferably Service-Disabled and/or Veteran-Owned Owned) entities within the Mountain Home area. THIS IS A REQUEST FOR INFORMATION ONLY. It is not a Request for Proposal, a Request for Quotation, an Invitation for Bids, a Solicitation, or an indication that Network-9 Contracting Office (NCO-9) will contract for the items contained in the RFI / Sources Sought Notice. This RFI/Sources Sought Notice is part of a Government market research effort to determine the scope of industry capabilities and interest, in accordance with Federal Acquisition Regulation (FAR) Part 15.201(e), response to this RFI / Sources Sought Notice are not offers and cannot be accepted by the Government to form a binding contract. Responses to this RFI / Sources Sought Notice are strictly voluntary and are consider as information only. The Government will not pay respondents for information provided in response to this RFI / Sources Sought Notice. Responses to this RFI / Sources Sought Notice will not be returned and respondents will not be notified of the result of the review. If a solicitation is issued, it will be announced a later date, and all interested parties must respond to that solicitation announcement separately from any response to this announcement. This RFI / Sources Sought Notice do not restrict the Government s acquisition on a future solicitation. Network-9 Contracting Office (NCO-9) and Mountain Home VA Medical Center are conducting market research for a Hoptel Services for the Department of Veterans Affairs (VA) at the Mountain Home VA Medical Center, Corner of Lamont & Veterans Way, Mountain Home, TN. 37684. Please review the draft Statement of Work (SOW) provided below before responding to the market research questions as the Government desires that respondents offer their experience and recommendations on the following questions and issues related to this requirement. When addressing these items, respondents should consider the size and scope of the requirement described herein. STATEMENT OF WORK: This is a summary of the Statement of Work. 1.0 INTRODUCTION The U.S. Department of Veterans Affairs requires the use of furnished hotel or motel rooms an average of 1-25 rooms per night ( the amount of hotel/motel rooms requested will vary based on VA lodging needs daily) each month. The rooms offered shall be within a five-mile radius of the James H. Quillen VA Medical Center, corner of Lamont & Veterans Way, Mountain Home, TN 37684. The contractor must be the established owner operator of the hotel/motel. 2.0 SCOPE 2.1 The Contractor shall provide fully furnished hotel or motel rooms weekly (the amount of hotel/motel rooms requested will vary based on daily VA lodging need, with the exception of Contractor black-out dates due pre-scheduled local area events). The fully furnished hotel/motel rooms will include contractor provided utilities. The hotel/motel rooms shall comply with all city, county and state building codes and ordinances applicable to the ownership and operation of the building in which the rooms are located. Rooms shall comply with the applicable NFPA 101, 2000, Chapter 29. 2.2 It is agreed by the Contractor that reserved rooms will be held until 11:00 pm each day. Any of the rooms that are not reserved by the VA will be available for the Contractor to place back in their inventory for sale and the VA will not be billed for rooms not used. 3.0 REQUIREMENTS All rooms shall be located in a single hotel or motel. Each room shall be on the ground floor or be elevator serviced. Access to rooms shall be from exterior hallways that are easily accessed from the front desk/elevator lobby area. The interior of the room shall not have any stairs. The rooms shall be smoke free. Contractor shall supply all utilities including heat, air conditioning, electricity, water and sewer, local telephone service, and basic television cable service. In the event the Veteran beneficiary is in an accident of any kind, the contractor shall first contact 911 emergency medical services to respond and then immediately notify authorized personnel of the Mountain Home VAMC, the AOD, or the COR of the emergency. A list of designated staff and contact information shall be provided to the contractor upon contract award. 3.9 Contractor shall provide each morning a continental breakfast or buffet, if available at no additional charge. On-site parking shall be available at no additional charge. 3.10 Occupancy: The VA must be able to take occupancy of the rooms no later than 14 calendar days following the award of the contract. The rooms must be in full compliance with all requirements of the contract by that date. 3.11 Inspection: The government reserves the right, at any time during the term of the contract, to inspect the premises and all other areas of the building to ensure a safe and healthy work environment for the Government tenants. 3.12 Room Reservations will be on the following basis: 3.12.0 The Contractor shall allow the occupancy of the room covered by this contract only upon the specific individual referral by the Contracting Officer s Representative (COR) or staff designated by the COR. The VA will inform the Contractor of arrival date and obtain a confirmation number from the Contractor. For this contract, the Contractor shall use its existing check in and check-out times. The COR or staff designated by the COR will notify the Contractor of when specific individuals will be checking out of the hotel/motel. In the event that a VA referred occupant refuses to leave the room, the Contractor shall immediately notify the COR. Also, in the event that a VA referred occupant checks out of the hotel/motel-without prior notice from the VA the Contractor shall immediately notify the COR or the VA Medical Center Officer of the Day if the check-out occurs in other than normal business hours. 3.13 The Contractor shall submit an invoice to the VA for payment for all rooms covered by this contract monthly in arrears. The invoice shall be for the actual number of rooms reserved in the previous month. Submit invoices to the following address: Dept of Veterans Affairs FSC P.O. Box 149971 Austin, TX 78714 Phone 1-866-372-1141 fax 512-460-5545 3.14 DAILY ROOM SERVICE: Daily room service shall be provided each room on the following basis: 3.14.0 If the previous night's occupant is different from the VA referred occupant for the next night, the bed linens will be changed daily as the room occupants change. 4.0 GENERAL BUILDING REQUIREMENTS & SPECIFICATIONS 4.1 Heating and Cooling Requirements: 4.1.0 Each room shall have permanently installed, functioning cooling and heating system with thermostatic control. All cooling and heating devices and appliances, shall be an approved type in good and safe working order and shall meet all installation and safety codes. Contractor shall maintain all appliances and utility systems Electrical and Lighting Requirements: 4.2.0 Every room shall be provided with not less than two electrical receptacle outlets and electric light fixtures in accordance with the Furniture and Accessories section of this solicitation. Every toilet room, bathroom, laundry room, furnace room, public hallway, porch and flight of stairs between stories shall contain at least one (1) supplied electric light fixture. Where an interior stairway or public hallway changes in direction, more than one (1) supplied electric light fixture is required. All electrical equipment, wiring and appliances shall be of an approved type, in good and safe working order and shall meet all installation and safety codes. 4.3 Sanitation Requirements: All plumbing fixtures shall be trapped and vented and connected to an approved sanitary sewer. All sanitary facilities, fixtures, equipment, structures and premises shall be of an approved type, in safe and sanitary condition and in good working order and meet all installation and safety codes. Telephone Service Requirements: 4.4.0 Contractor shall provide local area, touch tone, telephone service for each room. The telephone service shall be capable of long distance telephone service when long distance calls are placed using a telephone calling card or other telephone charge method. Contractor shall provide one telephone in each room. Telephone service shall be equipped with voice messaging system or front desk message service. Interior Space Requirements: 4.5.0 Ceilings shall be at least 8 feet and no more than 11 feet clear from floor to the lowest obstruction. Each room shall have acoustical treatment with a flame spread of ""5"" or less and smoke development rating of 50 of less (ASTME 84). Floor load shall be a minimum live load capacity of 60 pounds per square foot. Storage areas shall have a minimum live load capacity of 150 pounds per square foot. Floor shall be covered with vinyl floor covering or carpeting (vinyl asbestos floor tile shall not be used for new installations). Existing floor and/or window covering or carpet may be accepted providing the floor coverings are in good condition. Exterior doors to rooms shall open into a climate controlled hallway. Fire Safety: Buildings in which space is offered shall be evaluated in accordance with latest editions of the National Fire Codes and Uniform Building Code. 4.6.1 Equipment, services, or utilities furnished and activities of other occupants shall be free of safety, health, and fire hazards. When hazards are detected, the contractor shall promptly correct hazards. Maintenance of contractor-owned fire extinguishers shall be provided by the contractor in, accordance with NFPA Standard No: 101. As required by code, smoke detectors/alarms shall be installed in each room, office, storage area, hallways and other common areas. 4.7 Asbestos- No asbestos containing fireproofing or insulation on building structures, acoustical treatment, molded or wet-applied ceiling or wall finishes/decorations, will be permitted. 4.8 Wheelchair Accessibility: Common areas such as hallways and laundry room shall provide for accessible path of travel for wheelchairs. 4.9 Elevators: If elevators are a part of the room complex, they shall conform to the latest requirements of the American National Standard A171 and Al71a Safety Code for Elevators, except for elevator emergency recall and shall be inspected and maintained in accordance with American National Standard A17.1, Inspector's Manual for Elevators or equivalent local code. The elevators shall also comply with local codes and ordinances. 4.10 Miscellaneous: 4.10.0 No activity to the building and/or grounds that would cause an increase in dust, dirt or spores to be airborne (i.e., renovation to the building, movement of earth on the grounds) shall take place without the contractor's written notification to the VA at least seven (7) calendar days in advance of the event. 4.10.1 If the building is partially or totally destroyed or damaged by fire or other casualty so that the space is untenantable as determined by the Government, the government may terminate the contract upon 15 calendar days prior notice to the contractor and no further payments will be due. 4.10.2 The contractor shall maintain the premises, including the building and all equipment, fixtures, and appurtenances furnished by the contractor under this contract, in good repair and tenantable condition. 4.10.3 In the event the contractor fails to perform any service, to provide any item, or meet any requirement of this lease, the Government may perform the service, provide the item, or meet the requirement either directly or through a contract. The Government may deduct any costs incurred for the service or item, including administrative costs, from the payments. 4.10.4 The C&A requirements do not apply, and that a Security Accreditation Package is not required. 5.0 DELIVERABLES 5.1 FURNITURE AND ACCESSORIES: 5.1.0 Each room shall comply with the following general room requirements: (1) Each room shall double occupancy and be handicapped accessible, or be American Disability Act compliant. Access to rooms shall be from interior hallways that are accessed directly from the front desk/elevator lobby area. There shall be no physical barriers. Rooms shall be in a reasonably quiet or tranquil part of the hotel/motel. . 5.1.2 General Furniture Package (1) All furniture shall be in good general condition; shall be clean; free of stains and odors; and have no tears or rips in the fabric coverings. Non-upholstered furniture surfaces shall be free of scratches, broken surfaces, splinters, free of stains, and clean. (2) Each double size bed shall be supplied with the proper bed linens which will be freshly cleaned; free of stains, odors, tears, and in good condition. 5.1.3 Bathrooms must be properly cleaned with all the necessary accessories. MARKET SURVEY: 1. Please provide a capability statement that includes, as a minimum, the following information: a. Company Name: b. Company Address: c. Point of Contract Information: i. Name: ii. Title: iii. Phone Number: iv. Facsimile Number: v. E-mail Address: d. System for Award Management (SAM) Expiration Date: e. DUNS Number: f. CAGE Number: g. Business Size(*) (Note: (*) as it relates to NAICS Code: h. socioeconomic Category: Small Business SDVOSB VOSB Small Disadvantage Business 8(a) HUB Zone Women Owned Small Business 2. The number of rooms your firm can offer/provide: 3. The distance your firm is from the Mountain Home VA Medical Center Medical Center: 4. Comments on the (Draft) Statement of Work (SOW) provided below: 5. Comments on current market conditions and obstacles in providing these services to the Government: If interested, please provide a capability statement. Also, provide e-mail responses to this Request for Information (RFI)/Sources Sought Notice no later than Wednesday, February 9, 2021. The response time cannot be extended beyond the suspense date provided. THIS IS A REQUEST FOR INFORMATION/SOURCE SOUGHT NOTICE ONLY.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/a310dcb8208f4325b7ef689bf3a00b26/view)
 
Record
SN05899401-F 20210127/210125230105 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.