Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MARCH 06, 2021 SAM #7037
SOURCES SOUGHT

H -- Fire and Smoke Damper Inspection/Testing

Notice Date
3/4/2021 12:14:44 PM
 
Notice Type
Sources Sought
 
NAICS
541350 — Building Inspection Services
 
Contracting Office
241-NETWORK CONTRACT OFFICE 01 (36C241) TOGUS ME 04330 USA
 
ZIP Code
04330
 
Solicitation Number
36C24121Q0292
 
Response Due
3/9/2021 9:00:00 AM
 
Archive Date
05/08/2021
 
Point of Contact
John Shawki, Contract Specialist, Phone: 774-826-3192
 
E-Mail Address
issa.shawki@va.gov
(issa.shawki@va.gov)
 
Awardee
null
 
Description
THIS SOURCES SOUGHT/REQUEST FOR INFORMATION IS ISSUED FOR INFORMATION AND PLANNING PURPOSES ONLY AND IS NOT CONSIDERED A SOLICITATION. The purpose of this sources sought/RFI is to gain knowledge of businesses that are capable of satisfying the following work requirements: Statement of Work Fire and Smoke Damper Inspections Scope of Work The contractor will perform Fire and Smoke Door inspection at the Boston Healthcare System, West Roxbury Division. Contractor is responsible for all labor, materials, tools and special equipment required to perform the work. The work includes fire and smoke damper inspection, testing and documentation of: Building One-Qty 130 Building Two-Qty 134 Building Three-Qty 39 Contractor shall provide (1) electronic copy and (1) hard copy of individual inspection sheets for each door assembly inspected. Performance Requirements The periodic routine testing of existing fire damper includes: Clean debris from all surfaces of the fire damper Actuate each fire damper by removing the fusible link and making sure that the fire damper fully closes. Use pneumatic safety device if required to safely remove fusible link. Reset the fire damper. Use pneumatic safety device if required to safely re-install fusible link. Document the date that the fire damper was tested and if the fire damper passed or failed inspection. If a fire damper fails testing a detailed reason of why the fire damper failed will be provided. The fire damper testing report provided to the owner will be completed for each individual fire damper. Photograph each individual fire damper actuated and reset. Period of Performance: This is a one-time requirement. Options are not involved. The contractor will have 4 weeks to complete the work. Place of Performance: 1400 VFW Parkway, West Roxbury, MA 02132.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/c32d6b2ec498467b9b40c26d6797afca/view)
 
Place of Performance
Address: 1400 VFW Parkway, West Roxbury 02132, USA
Zip Code: 02132
Country: USA
 
Record
SN05933981-F 20210306/210304230115 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.