Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MARCH 13, 2021 SAM #7044
SOLICITATION NOTICE

Z -- Main Roof Replacement

Notice Date
3/11/2021 11:24:32 AM
 
Notice Type
Solicitation
 
NAICS
238160 — Roofing Contractors
 
Contracting Office
PBS R5 CHICAGO IL 60604 USA
 
ZIP Code
60604
 
Solicitation Number
47PF0021R0039
 
Response Due
3/15/2021 2:00:00 PM
 
Archive Date
03/30/2021
 
Point of Contact
Jennifer Dunne, Phone: 3123538796
 
E-Mail Address
jennifer.dunne@gsa.gov
(jennifer.dunne@gsa.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Description
The General Services Administration (GSA), Region 05, is seeking a qualified General Contractor (GC) for the Main Roof Replacement Project at the John W. Peck Federal Building in Cincinnati, Ohio. ��SCOPE OF WORK but is not limited to: The purpose of this project is to replace the existing lower main roof of the John Weld Peck Federal Building in Cincinnati. The existing construction of this building is a concrete and steel frame with stone and glass cladding and was built in 1961. The existing main roof structure, as noted in the existing drawings supplied bythe GSA, is a 17-inch deep, concrete waffle deck bearing on concrete wrapped, steel columns. The existing roof system that is being replaced is 32,456 S.F and is approximately seven years old. Test cuts of the existing roof revealed a 2-ply modified bitumen roof over a gypsum cover board over polyisocyanurate insulation with felt facers. This top roof assembly had been installed over a 3-ply built up asphalt roof system over a base sheet mopped over the concrete roof deck. The modified bitumen cap sheet is showing signs of granule based deterioration. The edges of the cap sheet are curling and splitting and the field of the roof is ponding water in several locations. It is the intention of the project to replace all the existing roof drains with new cast iron roof drains and match the roof system of the recently replace upper penthouse roof. This system is a 2-ply, cold applied SBS modified bitumen roof over a gypsum cover board over polyisocyanurate insulation over a temporary roof. In order to simplify maintenance and create a single source for warranty purposes, the recommended manufacturer of the main roof system is Siplast. In addition, the roof slope would be increased to � inch per foot to improve roof drainage.� Attach Amendment 0001 and 0002, sign in sheet and agenda for preproposal
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/495950c2ea064d8e91cd65b1a0d05935/view)
 
Place of Performance
Address: Cincinnati, OH 45202, USA
Zip Code: 45202
Country: USA
 
Record
SN05940044-F 20210313/210311230116 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |