Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MARCH 18, 2021 SAM #7049
SOLICITATION NOTICE

56 -- Emergency Department Doors Removal and Installation

Notice Date
3/16/2021 7:28:35 PM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238290 — Other Building Equipment Contractors
 
Contracting Office
248-NETWORK CONTRACT OFFICE 8 (36C248) TAMPA FL 33637 USA
 
ZIP Code
33637
 
Solicitation Number
36C24821Q0563
 
Response Due
3/19/2021 9:00:00 AM
 
Archive Date
04/18/2021
 
Point of Contact
John H. Shultzaberger, Contracting Officer, Phone: 352-381-5728
 
E-Mail Address
John.Shultzaberger@va.gov
(John.Shultzaberger@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
See below questions and answers pertaining to solicitation 36C24821Q0563 1,  Can you provide a floor plan showing the area of where the doors needed replacement are located? Answer: Yes. Drawing attached. Rooms J148-1 through J157-1 are the required installation locations.   2,  Who is the manufacturer of the existing doors? Answer: Assa Abloy.   3.  Will the installation be expected.      a. night      b. day      c.  weekend Answer: Night, day, and weekend work can be expected. 4.  Is there a staging area on premises? Answer: Yes. 5.  Site training required? Answer: Yes, upon completed installation of each different style of door. 6.  Background checks/etc? Answer: 10-Hour OSHA training card for each employee. Project manager is required to maintain a 30-Hour OSHA training card.   7.  Door Requirements: door perimeter mounted with curtain wall       Does the curtain wall exist?       Or is the opening sheet/metal stud framed. Answer: Sheet/metal stud framed. 8.  Full breakout in any position may require recessed track.      Concrete cutout in floor may be required.  NOT BY DCS.      Is there any issue with dust and noise when this type of work is being performed. Answer: Installed door must fit in existing location without modification to concrete deck. Concrete grinding or cutout is not permissible in this area. 9.  Glass is to be ¼ temp, any type of tint? Answer: Clear glass without tint.      Is it possible Interior Blind glass is required? Answer: Interior blinds are not required. 10. I was just preparing our proposal for 36C24821Q0563 Emergency Department Doors Removal and Installation and I notice that you have referenced submitting an SF 1449.  There is not one issued with the docs in Beta.Sam.gov.  Will you be issuing with one with an Amendment? Answer: The SF1449 document is not required to be submitted with this procurement. That provision is used in both combined synopsis solicitation and RFQ s that are posted using the actual SF1449. I will be posting clarification as well in the amendment containing other questions and answers.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/3f0672c130b84edda877533ccc0ed62f/view)
 
Place of Performance
Address: Department of Veterans Affairs North Florida/South Georgia VHS Malcom Randall VA Medical Center 1601 SW Archer RD, Gainesville, FL 32608, USA
Zip Code: 32608
Country: USA
 
Record
SN05944503-F 20210318/210316230121 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.