SOURCES SOUGHT
65 -- DUET Suction Unit
- Notice Date
- 3/17/2021 12:03:08 PM
- Notice Type
- Sources Sought
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 244-NETWORK CONTRACT OFFICE 4 (36C244) PITTSBURGH PA 15215 USA
- ZIP Code
- 15215
- Solicitation Number
- 36C24421Q0423
- Response Due
- 3/16/2021 12:00:00 PM
- Archive Date
- 03/26/2021
- Point of Contact
- andrew.taylor3@va.gov, Andrew Taylor, Phone: (724) 285-2533
- E-Mail Address
-
Andrew.Taylor3@va.gov
(Andrew.Taylor3@va.gov)
- Awardee
- null
- Description
- THIS IS NOT A SOLICITATION ANNOUNCEMENT. THIS IS A REQUEST FOR INFORMATION ONLY. This Request for Information (RFI) is intended for information and planning purposes only at this time; and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Because this is a Request for Information announcement, no evaluation letters and/or results will be issued to the respondents. No solicitation exists. Therefore, do not request a copy of a solicitation. Statement of Need SSCOR Duet Suction Unit _Aspirators Introduction The Department of Veteran Affairs Medical Center, 1111 East End Blvd, Wilkes-Barre, PA. 18711- BioMedical service has determined the need to purchase DUET Suction Unit manufactured by Armstrong. Justification: This replacement request is f for 44 SSCOR Duet Suction Units that are at or have past life expectancy. Batteries are failing at a high rate and are expensive for replacement and new Units come with a 3-year battery warranty. Request for new units made by BIOmed. Brand name or equal procurement of the requested SSCOR Duet Suction Unit Model # AE 6975 is consistent with currently used equipment and would allow us to continue to utilize the current supplies on hand. Requirements: An AC suction unit with battery back-up, the Duet provides instant, powerful suction whether or not AC power is available. Built-in charger maintains battery and will not overcharge. at all times for maximum battery health. 3 year battery replacement policy for properly cared for devices! When fully charged, the sealed lead acid battery provides 45 minutes +/- 10% of suctioning power, giving you the suction you need for emergency care procedures. Battery condition indicator. 1200cc Bemis canister included. Pump Airflow must be greater than 30 lpm and capable of at least 500 mmHg Clinical Airflow: 30+ lpm (achieved at tip of patient tubing). Size: 17""L x 9""H x 6""W; weighs 10.5 lbs. Battery Type: Sealed lead acid. Flat back unit sits conveniently on a cart or shelf. Bracket back unit will attach to the side of the cart or to a wall saving valuable shelf and cart top space. Quantity: 44 Delivery: Delivery accepted at VAMC Wilkes Barre, Warehouse, 1111 East End Blvd, Wilkes Barre, PA 18711; Weekdays 8:00am 4:00pm, excluding any government holidays. POC Dennelle Ripka X 27632 Request for Information - Instructions The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above. Responses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, DUNS Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 339112 (size standard of 1000 employees). Please answer the following questions: Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? Is your company considered small under the NAICS code identified under this RFI? Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? If not, Can you provide additional information shown below. This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers. Does your company exceed 500 employees Primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied; Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice; Obtained an individual or class waiver? If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to sub contracted work and completion of job. Does your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number. If you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. Please submit your capabilities in regard to the salient characteristics detailed above and any information pertaining to equal to items to establish capabilities for planning purposes? (11) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A. (12) Please provide your DUNS number. *** Submissions addressing number (10) should show clear, compelling and convincing*** evidence that all equal to items"" meet all the salient characteristics. This RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 13. Telephone responses will not be accepted. Responses must be received via e-mail to Andrew.Taylor3@va.gov no later than, 03:00 PM Eastern Standard Time (EST) on April 5, 2021. This notice will help the VA in determining available potential sources only. Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action. All questions will be addressed by the Contracting Officer, Andrew Taylor. All firms responding to this Request for Information are advised that their response is not a request for proposal, therefore will not be considered for a contract award. If a solicitation is issued, information will be posted on the beta.sam web site for all qualified interested parties at a later date and interested parties must respond to the solicitation to be considered for award. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information. Information will only be accepted in writing by e-mail to Contracting Officer at andrew.taylor3@va.gov. DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/a583fb6e1ce0492ebc2055a7fed4886e/view)
- Place of Performance
- Address: Wilkes Barre VA Medical Center 1111 East End Blvd Wilkes-Barre, PA. 18711 18711, USA
- Zip Code: 18711
- Country: USA
- Zip Code: 18711
- Record