Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MARCH 19, 2021 SAM #7050
SOURCES SOUGHT

65 -- Monitoring Systems for the Clement J. Zablocki VAMC located in Milwaukee, Wisconsin. BRAND NAME OR EQUAL.

Notice Date
3/17/2021 8:42:31 AM
 
Notice Type
Sources Sought
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
252-NETWORK CONTRACT OFFICE 12 (36C252) MILWAUKEE WI 53214 USA
 
ZIP Code
53214
 
Solicitation Number
36C25221Q0504
 
Response Due
3/22/2021 9:59:00 PM
 
Archive Date
04/21/2021
 
Point of Contact
Thomas H Chesak, Contracting Officer, Phone: 414-844-4813
 
E-Mail Address
thomas.chesak@va.gov
(thomas.chesak@va.gov)
 
Awardee
null
 
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI  53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide Monitoring Systems, TwitchView System (OEM: BLINK DEVICE COMPANY) brand name or equal, for the Clement J. Zablocki VAMC in Milwaukee, Wisconsin. General Requirements: BRAND NAME (TwitchView System - OEM: BLINK DEVICE COMPANY) OR EQUAL: Twenty (20) TwitchView Systems (p/n: TVSYS01) Shall meet the requirements of the following technical specifications: - Constant current, monophasic square wave. - Current range must be within: 0 80 mA: - ±5% of full-scale value above 20mA. - ±1 mA below 20mA. - Pulse width to be 100µs, 200µs, or 300µs. - Real-time noise cancellation for enhanced accuracy. - Maximum stimulation voltage shall not exceed 300V. - Maximum load shall not exceed 3.75 kOhm. - Frequency: 1Hz 50Hz ±5%. - EMG accuracy shall be within +/- 5%. - Battery Type: Lithium Ion, Rechargeable, 4.0 V, 3000 mAh. - Battery Life to be no less than 6 hours when fully charged. - Shall have touchscreen display. Ten (10) TwitchView Adult Electrode Array (p/n TVESA01) - 25 per case minimum. - Shall be single-use electrodes. - Shall be able to place on patient s hand or foot. Two (2) TwitchView Power Cables (p/n: TVAEA025) - Minimum 10FT long. - Shall be 120 V. Three (3) In-Service 1-Day (p/n: TVCAB01) - In-person staff training customized per facility request. - Total of 3 days. Twenty (20) TwitchView Extended Service Agreement (p/n: TVINSERVICE) - Minimum three (3) year service agreement (will be option years). - Parts and labor costs to replace or repair the TwitchView System Monitor and/or Charging Dock during the extended period shall be fulfilled. All interested firms who can meet the requirements stated above should respond, in writing, INCLUDING ALL THE FOLLOWING: Company name. Address. Point of contact (name/title/telephone number/e-mail address). FSS / SEWP Contract number, if applicable. DUNS number. Tax ID number. Indication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies. A capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above. Documentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer. Submit responses to the Contracting Officer, Thomas Chesak, at thomas.chesak@va.gov no later than 11:59 PM (Central Standard Time), 22 March 2021. 36C25221Q0504 Monitoring Systems for Milwaukee VAMC shall be referenced on all correspondence regarding this announcement. TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED. The NAICS Code 334510, Electromedical and Electrotherapeutic Apparatus Manufacturing, is applicable to this acquisition; the size standard is 1,250 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/977a2e37f8294bf08800b75f06c31046/view)
 
Record
SN05946125-F 20210319/210317230116 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.