66 -- Beta Microplate Reader

Notice Date
3/22/2021 2:03:41 PM
 
Notice Type
Sources Sought
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
NATIONAL INSTITUTES OF HEALTH NIDA Bethesda MD 20892 USA
 
ZIP Code
20892
 
Solicitation Number
NIMH-SBSS-21-002741
 
Response Due
4/1/2021 8:00:00 AM
 
Archive Date
04/02/2021
 
Point of Contact
Kim Stapleton, Valerie Whipple
 
E-Mail Address
kim.stapleton@nih.gov, valerie.whipple@nih.gov
(kim.stapleton@nih.gov, valerie.whipple@nih.gov)
 
Description
This is a Small Business Sources Sought notice. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding: (1) the availability and capability of qualified small business sources; (2) whether they are small businesses; HUBZone small businesses; service disabled, veteran-owned small businesses; 8(a) small businesses; veteran-owned small businesses; woman owned small businesses; or small disadvantaged businesses; and (3) their size classification relative to the North American Industry Classification System (NAICS) code for the proposed acquisition. Your responses to the information requested will assist the Government in determining the appropriate acquisition method, including whether a set-aside is possible. An organization that is not considered a small business under the applicable NAICS code should not submit a response to this notice. This notice is issued to help determine the availability of qualified companies technically capable of meeting the Government requirement and to determine the method of acquisition. It is not to be construed as a commitment by the Government to issue a solicitation or ultimately award a contract. Responses will not be considered as proposals or quotes. No award will be made as a result of this notice. The Government will NOT be responsible for any costs incurred by the respondents to this notice. This notice is strictly for research and information purposes only. The information requested will assist the Government in determining the appropriate acquisition method including small business socioeconomic set aside possibilities and to determine the availability of qualified Small Business companies technically capable of meeting the Government's potential requirement. All Small Business companies with the capability and availability to perform the requirement under the applicable NAICS code is invited to submit a response to this notice. Background: The Molecular Imaging Branch current liquid scintillation counter (Tricarb-3100TR), which is in building 49 (Rm B1A59) in our in vitro binding assay lab, is over 16 years old. This instrument is no longer supported by the manufacturer. A new replacement system is needed which allows performance at a higher throughput study. The old system has been used efficiently with protocols that were optimized to allow efficient procedures, but an improvement in a higher throughput studies with shorter time between start and obtaining useful results is needed. The requested Beta Microplate Reader instrument will be used to shorten the assay time and increase the throughput studies. Furthermore, although the MicroBeta system is a completely different technology and assay system, it will still allow us to use our existing protocols for comparative purposes and to allow secure switching to the new instrument. These studies include, but are not limited to, the investigations of selecting promising compounds that we synthesize and are targeting in human cyclooxygenase 1 and 2 (COX-1 & 2). The efficient assays for these two targets would be important to support our proposed protocols in finding compounds to radiolabel with 11C- and 18F- and perform positron emission imaging (PET) studies. Thus, the goal of our work is the successful research and development of brain receptor imaging.� Purchase Description: Beta Microplate Reader Salient characteristics: There are numerous characteristics that are useful about the Beta Microplate Reader system, but most importantly are the following: Has dual-PMT coincidence counting for top and bottom reading (2 PMT's per detector) which is essential in eliminating sample to sample assay variability. The feasibility of a 16-shelf load capacity (that can hold 16 plated or a 5 of the 4 mL vial cassettes. This allows the high throughput and with the 4 mL vials allows the merging of our old protocols with the new ones. Can count 4mL vials with special cassette adapter or Eppendorf tubes with special cassette and adapter allows large research flexibility in our assay. Has an internal computer running Win10 OS which allows ease in data processing and management of several projects at the same time. Quantity: one (1) Delivery Date: Thirty days after receipt of order. Period of Performance: N/A Warranty: one year (parts, labor, and travel) Capability Statement: Interested parties are expected to review this notice to familiarize itself with the requirements of this product or service. Failure to do so will be at your firm's own risk. Respondents must provide, as part of their response: (a) product, catalog, model, and/or part number(s); (b) product description; (c) best estimated delivery date after receipt of order; (d) all relevant information and documentation that the item(s) offered meets the salient physical, functional, or performance characteristics as specified in this announcement. Respondents that believe that they are authorized resellers of the equipment described in this announcement may provide, in addition to the aforementioned information, as part of their response: quantity; estimated price or cost; shipping, handling, and/or installation charges. The respondent must also provide their DUNS number, organization name, address, point of contact, and size and type of business (e.g., 8(a), HubZone, etc.) pursuant to the applicable NAICS code and any other information that may be helpful in developing or finalizing the acquisition requirements. One (1) copy of the response is required and must be in Microsoft Word or Adobe PDF format using 11point or 12point font, 8-1/2"" x 11"" paper size, with 1"" top, bottom, left and right margins, and with single or double spacing. The response is limited to ten (10) page limit. The 10-page limit does not include the cover page, executive summary, or references, if requested. The information submitted must be in an outline format that addresses each of the elements of the product requirement. A cover page and an executive summary may be included but is not required. The response must include the respondents' technical and administrative points of contact, including names, titles, addresses, telephone and fax numbers, and email addresses. Respondents must reference announcement number NIMH-SBSS- 21-002741 on all correspondence related to this Small Business Sources Sought notice. The response must be submitted to kim.stapleton@nih.gov and valerie.whipple@nih.gov and be received prior to the closing date specified in this announcement. Concluding Statements: Disclaimer and Important Notes. This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a presolicitation synopsis and solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation. Confidentiality. No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any nonproprietary technical information in any resultant solicitation(s).
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/0c47da74e04b43b88e4efdbcb7a72f27/view)
 
Place of Performance
Address: USA
Country: USA
 
Record
SN05950106-F 20210324/210322230115 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)