Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF APRIL 01, 2021 SAM #7061
SOLICITATION NOTICE

65 -- Safety Service PortaCount Equipment

Notice Date
3/30/2021 11:13:34 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
257-NETWORK CONTRACT OFFICE 17 (36C257) ARLINGTON TX 76006 USA
 
ZIP Code
76006
 
Solicitation Number
36C25721Q0598
 
Response Due
3/31/2021 1:00:00 PM
 
Archive Date
04/02/2021
 
Point of Contact
Myrtis Clemons, Contract Specialist, Phone: 210-694-6317
 
E-Mail Address
Myrtis.Clemons@va.gov
(Myrtis.Clemons@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
STATEMENT OF WORK (SOW) QUANTITATIVE RESPIRATOR FIT TESTER A. GENERAL INFORMATION Title of Project: Quantitative Respirator Fit Tester Scope of Work: The Central Texas VA Health Care System (System (CTVHCS) Safety Services, located at 1901 South First Street, Temple, Texas 76504, requestsis requesting solicitations for the purchase of 2-quantitative fit test machines. The machines should be PortaCount Brand Name or Equal. It is anticipated and expected for bothThe fit testers to have all should include all associated parts and accessories (including software) necessary for successful stand-alone, out-of-the box fit testing capabilities of both N-95 filtering face-piece respirators and half-face elastomeric respirators. Successful fit testing will meetFit Testing is expected to meet all OSHA requirements for quantitative fit testing as described in the Code of Federal Regulations, 29CFR 1910.134. Background: A quantitative fit test (QNFT) is one type of respirator fit test used to determine whether a respirator properly fits an individual employee. Respirator fit tests are used with tight fitting respirators to ensure a proper face-to-face-piece seal is achieved. Without a proper fit, ambient air can leak into the respirator and expose the wearer to airborne contaminants. U.S. Occupational Health and Safety (OSHA) regulations require that a respirator fit test be performed when a worker initially selects and is fitted for a tight-fitting respirator. Additional testing must be performed at least annually. Quantitative fit-testing is performed by collecting and analyzing air samples from within the respiratory inlet cover of the respirator while it is worn by the intended user. This collection is accomplished through use of a hose inserted into the face piece of the respirator, which then delivers the air sample to a separate device for analysis. This testing procedure results in a numeric value for the level of contaminants within the respirator by comparing this number to the concentration of the contaminant outside the mask. A fit-factor is calculated that indicates if and at what level any leakage exists when the worker is wearing the selected respirator Note: A quantitative fit test differs from a qualitative fit test because the latter relies on subjective feedback from the wearer to detect potential leaks. Salient Characteristics:RequirementsThe salient characteristics should include the features or specifications required for the machines. It should not include both machines. This would go in the MR document not the SOW. This will confuse the vendors and they will ask more questions like which do you want which will force us to choose one for you. Remove the company #1 and Company #2 this doesn t belong. Example: Compatible with new Modified CNC Protocols OSHA, CSA, HSE and ANSI Compliant for all tight-fitting respirators, including series 95, 99, 100, FFP1, FFP2 and FFP3 filtering facepiece respirators Built-in N95 Companion technology Measures fit factors greater than 10,000 Switch between N95 and N99 mode of operation in seconds Automates fit testing with FitPro+ Fit Test Software Standalone operation - no external computer required Use with external computer to generate reports and print fit test cards Color touchscreen enables operation via touch of a finger, pen or stylus Compatibility with FitPro Ultra Software available : Manufacturers that make quantitative fit test machines are limited due to the specialization required and the limited demand for the equipment. Fit tester selection becomes even more selective within Health Care Organizations who are required to use disposable N-95 filtering face-piece respirators, of which only two brands of fit test machines have been identified as being acceptable. The two brands acceptable for this solicitation are the Portacount Model 8048 or the Accufit 9000- PRO. General Characteristics: The Fit Tester must be able to perform Fit Testing Procedures as annotated in the OSHA Standard 1910.134, Part A, Fit Testing Procedures-General Requirements, and meet fit testing protocol for: Modified ambient aerosol condensation nuclei counter (CNC) quantitative fit testing protocol for full-facepiece and half-mask elastomeric respirators, Table A-1, and Modified ambient aerosol condensation nuclei counter (CNC) quantitative fit testing protocol for filtering facepiece respirators, Table A-2 Fit Test Machine must contain all accessories for out-of-the box fit testing, peripherals for maintaining operations for up to one year, data storage for both tablet input and software for database management. Compatible tablets should be included with each fit test machine. Contract should provide a minimum of a two-year service agreement for annual cleaning and calibration. Additional Salient Characteristics: Additional Salient characteristics for specific brands being considered: Company #1 Instrument Name: Portacount Model 8048-T Brand Name or Equal Manufacturer and Distributor: TSI 500 Cardigan Road Soreview, MN 55126 PortaCount Model 8048-T Company is regarded as the #1 supplier of quantitative fit testing equipment Years of experience Replacement parts readily available Comes with a tablet- no IT interface required Porta count 4048-T Salient Characteristics: Compatible with new Modified CNC Protocols OSHA, CSA, HSE and ANSI Compliant for all tight-fitting respirators, including series 95, 99, 100, FFP1, FFP2 and FFP3 filtering facepiece respirators Built-in N95 Companion technology Measures fit factors greater than 10,000 Switch between N95 and N99 mode of operation in seconds Automates fit testing with FitPro+ Fit Test Software Standalone operation - no external computer required Can be used with external computer to generate reports and print fit test cards. Color touchscreen enables operation via touch of a finger, pen or stylus Capable of fit testing in extremely clean environments to include particle generator if required to complete the fit test. Each Fit Tester must include the following: 8026 Particle Generator (115 VAC); Alcohol Cartridge; Alcohol Fill Capsule; Storage Cap; (2) Zero Check Filters; 3/16"" and 1/4"" Hose Adapters; (2) Spare Alcohol Wicks; (100) Sampling Probes; (100) Lock Washers; Probe Insertion Tool; Neck Strap; 8016 Alcohol Supply containing (16) 30mL Bottles of Reagent Grade Isopropyl Alcohol; FitPro Ultra Fit Test Software; Data Collector; USB-A & USB-C Cable; 2-Year Warranty Fit Test Sampling Probe Kit -N-95 Probe Kit for fit testing disposable filtering-facepiece respirators. Includes Installation Tool Set, 1500 Probes, 1500 Push Nuts, Instructions. Fit Test Adapter Kit for 3M Half Face 6000 respirators Minimum quantity of 4. Fit Test Adapter Kit for fit testing disposable, filtering facepiece N-95 respirators, to include as a minimum ium components for 500 fit tests. Calibration peripherals. 2-year calibration, cleaning and maintenance contract. Factory Calibration Certificate 5. Deliverables: Two Quantitative Fit Testers ready for operation. Two compatible tablets. All accessories including 3- probe devices for penetration 1of 500 probes and nuts for use with disposable filtering facepiece N-95 respirators. Probe attachments for 3M6000 Half Face Respirator (4) 2-year cleaning, maintenance & calibration contract for each fit test machine Software for non-network to laptop.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/f3bd472b948f4e65972c058f04b65ed2/view)
 
Place of Performance
Address: Department of Veterans Affairs Olin E Teague VAMC 1901 Veterans Memorial Dr., Temple, TX 76504-7451, USA
Zip Code: 76504-7451
Country: USA
 
Record
SN05957452-F 20210401/210331083227 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.