SOLICITATION NOTICE
59 -- UPS Capacitors and Fans Replacement
- Notice Date
- 4/1/2021 1:36:48 PM
- Notice Type
- Solicitation
- NAICS
- 33441
—
- Contracting Office
- 255-NETWORK CONTRACT OFFICE 15 (36C255) LEAVENWORTH KS 66048 USA
- ZIP Code
- 66048
- Solicitation Number
- 36C255Q0292
- Response Due
- 4/8/2021 1:00:00 PM
- Archive Date
- 04/23/2021
- Point of Contact
- Jon LutmerJonathan.lutmer@va.gov 410-446-3862, Phone: 410-446-3862
- E-Mail Address
-
Jonathan.lutmer@va.gov
(Jonathan.lutmer@va.gov)
- Small Business Set-Aside
- SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Description
- Statement of Work � UPS CAPACITOR AND FAN REPLACEMENT � INTRODUCTION � The Maintenance and Operations (Facilities) is responsible for the operation, maintenance and repair of Robert J Dole VA Medical Center; The Medical Center is located at 5500 East Kellogg (US 54) in Wichita, Kansas herein after referred to as the ""job site"". SUMMARY OF WORK � The contractor will perform the work described below for the 9315 300/330kVA Full Capacitor and Fan Replacement on the (Cath Lab UPS) and the Mitsubishi 2033A 75kVA (:IT� UPS) ����� New Capacitor and Fan Replacements Parts � Cath lab Bldg. 2 ������ (36) Duracap Capacitor � 5,800 uF, 300VDC (36) Aerovox Capacitor � 40uF, 600VAC, 4.75� Length, 2.5� Dia., Spade Terminals, Mounting (18) Aerovox Capacitor � 60uF, 370VAC, 3.875� Length, 2.5� Dia, Spade Terminals, Mounting Stud (3) Duracap Capacitor � 150.000. 35VDC (10) Cpp;trpm Fam-Axoa;. 24VDC. Sensing. Mew )��� shipping, Freight, Delivery and Handling Charges � Ground Service/Labor for UPS � Normal Hours ������ New Capacitor and Fan Replacements parts � IT area Bldg. 19 (8)� Capacitor � 2800uF, 450 VDC (1)� Capacitor - 3x298uF, 220 VAC (1)� Capacitor � 3x83uF, 240 VDC (2) Capacitor � 0.027uF, 1600 VDC (1) Capacitor � 33,000uF, 35 VDC ���(2) Fan � Axial, 200VAC, 3 phases new ����� ������ New Capacitor Inspection Inspect new capacitor to ensure correct capacitor and quantity received. Inspect new capacitor for any damages prepare mew capacitor for installation Measure/test new capacitor ������� Replacement � With Client permission, take system out of service (transfer system to bypass). If required and available transfer system to external maintenance bypass. ���� I NOTE: Some makes and models may require system and attached loads to be de-energized for ����������� Complete capacitor replacement. Disconnect and remove existing capacitor. Install new capacitor. Re-install capacitor connections Correct any corroded or damaged cables/connections. If external maintenance bypass was utilized. With client permission. Place system back into service (transfer unit out of bypass) Record as left condition. Discuss findings with customer and provide field service report. Dispose of old capacitors, packing, and refuse in client approved manor. Note 1: See capacitor proposal for additional scope of work. Note 2: Scope of work may be generic and subject to change to accurately reflect equipment on���� site. Note 3: Capacitor replacement performed in accordance with IEEE and OEM standards. Note 4: Complete power down of unit and supported loads may be required
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/923b98a5d066449bac5a273a775e3214/view)
- Place of Performance
- Address: Wichita, KS 67218, USA
- Zip Code: 67218
- Country: USA
- Zip Code: 67218
- Record
- SN05960366-F 20210403/210401230116 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |