Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF APRIL 07, 2021 SAM #7067
MODIFICATION

59 -- Isolation Panels Deficiencies Correction

Notice Date
4/5/2021 2:40:44 PM
 
Notice Type
Solicitation
 
NAICS
561210 — Facilities Support Services
 
Contracting Office
255-NETWORK CONTRACT OFFICE 15 (36C255) LEAVENWORTH KS 66048 USA
 
ZIP Code
66048
 
Solicitation Number
36C25521Q0297
 
Response Due
4/9/2021 10:00:00 AM
 
Archive Date
04/24/2021
 
Point of Contact
Jon LutmerJonathan.lutmer@va.gov 410-446-3862, Phone: 4104463862
 
E-Mail Address
Jonathan.lutmer@va.gov
(Jonathan.lutmer@va.gov)
 
Description
STATEMENT OF WORK Isolation Panels Deficiencies Corrections Robert J. Dole VA Medical Center Scope of Work � Scope The contractor shall provide complete software package and any additional Hardware, inter-connection cable, tools, equipment, parts, machinery and manpower to repair or make needed calibrations at the Robert J. Dole Medical Center (VA). �Lock out / Tag out procedures must be followed on all energized / deenergized circuits. �Based on the last Electric Field Service test report the following services will be needed. �Field Services contractor will provide (1) Field Service Representative(s) to be On-Site for (2) Days. �Building 34 Panel OR2-IPU3 �Green light is out�-Replacing defective remote indicator and Line Isolation Monitor. �Building 02 Panel Cath Lab-IP-CL2� Audible Alarm is faulty� Replace panel indicator, remote indicator and Line Isolation Monitor. Alternate: In addition, found issues with the grounding in booms that SE wasn�t testing as part of the inspection project. In OR3-the recommendation is that the electrical contractor who installed the ISO Panels be called back to perform this work.� Retesting to be completed after completion. � RJDMC Responsibilities �Provide free and clear access to the equipment. �Provide qualified personnel familiar with the electrical equipment to perform all switching, de-energization, re-energization, grounding and lockout of the equipment. �Coordinate all power outages and absorb any related costs. �Provide lighting and 120V power with GFI for Square D Services' onsite electrical equipment, if required. �Provide a list of job site hazards specific to its operation. These may include, but are not limited, to confined spaces, presence of chemicals and contaminants, and other operations in the area. �Provide emergency response training or documentation to Square D employees. �Notify its own employees to keep unqualified employees away from the work area for their own protection. �All costs, if any, incurred due to rescheduling of services. �Labor and expense cost overruns due to 1) delays by others; or 2) equipment is not ready to be serviced. � Work Not Included �Any site-specific or customer-specific safety or clearance training greater than one hour conducted during the date of service or required outside the dates of service. Schedule _X Shutdown scheduled working hours: Monday through Friday, 5:00pm � 3:00am. * *Excluding holidays, unless otherwise specified � Scheduling will be set up by VA personnel and work will start within 24 hours �of the VA personnel request or an agreed upon time and date. Service Provided by Contractor Contractor will provide: Correction of deficiencies as stated �Locks for Lock out / tag out requirements �Qualified personal �Repairs equipment or parts as needed. Installation Labor Re-testing of corrected deficiencies � Required Services The contractor shall provide a complete turnkey installation of all software And any hardware interconnections required for proper operation.�� The contractor shall Provide full maintenance on site to include all replacement parts, labor, travel expenses, Shipping charges, tools, test equipment and other incidentals necessary to maintain or Restore the listed workstations to operation specifications according to the manufactures� Recommendations from one year after installation at no extra charge.� The maintenance Shall be provided during business hours of 7:30AM � 5:00PM, Monday thought Friday unless otherwise noted, Excluding federal holidays. �Identification, Parking, and Smoking VA Regulations The contractor shall obtain a contractor�s badge from the Engineering office �in Building 20.� The badge shall be worn in a visible location on the worker at all �times while on the premises of the VA property.� It is the responsibility of the contractor �park in the appropriate designated parking areas.� Information on parking is �available from the VA Police.� The VA will not invalidate or make reimbursement for �parking violations of the contractor under any condition.� Smoking is prohibited inside �any buildings at the VA.� All completed service or installations will be confirmed and �approved by a VA Engineering COR.� On completion of service the contractor � must return Identification badge back to building 20.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/ceca8d71871949bebc0666611bb8f176/view)
 
Place of Performance
Address: Wichita, KS 67218, USA
Zip Code: 67218
Country: USA
 
Record
SN05962177-F 20210407/210405230058 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers