Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF APRIL 24, 2021 SAM #7084
SOURCES SOUGHT

65 -- AUDIO HI-PRO 2 PROGRAMMER

Notice Date
4/22/2021 4:34:24 PM
 
Notice Type
Sources Sought
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
262-NETWORK CONTRACT OFFICE 22L (36C262) LONG BEACH CA 90815 USA
 
ZIP Code
90815
 
Solicitation Number
36C26221Q0660
 
Response Due
4/28/2021 4:00:00 PM
 
Archive Date
05/28/2021
 
Point of Contact
adriana.garcia@va.gov, Contract Specialist, Phone: 562-766-2227
 
E-Mail Address
adriana.garcia@va.gov
(adriana.garcia@va.gov)
 
Awardee
null
 
Description
This is a sources sought synopsis only. The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classification (hubzone, 8(a), small, small disadvantage, small veteran owned business or service disabled veteran owned small business) relative to NACIS 334510 (size standard of 500 employees). Responses to this synopsis will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought synopsis, a solicitation announcement may be published in the Fedbizopps website. Responses to this sources sought synopsis are not considered adequate responses to the solicitation announcement. All interested offerors will have to respond to the solicitation announcement in addition to responding to this sources sought announcement. The Department of Veterans Affairs, Network Contracting Office NCO22, is seeking sources for vendors to purchase 39 Hi-Pro 2 Audiology Systems for the VA San Diego Healthcare System. The anticipated award date shall be 7/1/21 to coincide with the opening of the Kearny Clinic in San Diego. If you are interested and are capable of providing the required services please provide the requested information as indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Is your business small (2) If small, does your firm qualify as a small, emerging business, or small disadvantaged business? (3) If disadvantaged, specify under which disadvantaged group and if your firm is certified under Section 8(a) of the Small Business Act? (4) Is your firm a certified Hubzone firm? (5) Is your firm a woman-owned or operated business? (6) Is your firm a certified Service-Disabled Veteran Owned Small Business, (7) Is your firm a Veteran Owned Small Business? Small businesses considering participation in this potential solicitation process under any Small Business Set-aside procedure must do so in a manner consistent with the requirements of the Small Business Act. Responses to this notice shall be e-mailed to Adriana.garcia @va.gov. Telephone responses will not be accepted. Responses must be received in writing no later than 3:30 p.m.4/28/21. This notice is to assist the VA in determining sources only. A solicitation is not currently available. If a solicitation is issued it will be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this announcement. Responses to this sources sought is not a request to be added to a prospective bidders list or to receive a copy of the solicitation. The Salient Characteristics for the Hi-Pro 2: Must have: Universal programming interface for all hearing instrument brands USB connectivity Backward compatible must work with any hearing instrument that has been programmed by a Hi-Pro device, regardless of version PC Interface: Communication: USB 2.0 full speed (USB 1.1 compatible) USB Connector Type: Type B connector (on the Hi-Pro 2 unit) Power Supply: The Hi-Pro 2 unit is powered from the PC USB port Operating systems: Windows XP Pro SP3, Windows 7 (32 and 64 bit), Windows 8 (32 and 64 bit), Windows 10 Measurements must fit in existing clinical space: Work bench: 53 height X 32 length X 22 depth Jodivac XL: 2.5 height X 9 length X 6 depth Heavy-duty casters. Integrity meter to measure battery drain, transducer functionality, consistency of volume control taper. Acute atmospheric pressure reduction chamber. Vacuum/air delivery (required to comply with RME policy). Industrial grade diamond bits in multiple sizes with quick change chuck. Adjustable work light. Magnification lens. Compound-treated buffing wheel with padded safety bin. Ultra shell material and UV curing chamber. Pull-out work shelf. Clinical and biomed service training included.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/81b0ef9e488b457cb460eb238f417f20/view)
 
Place of Performance
Address: 3550 La Jolla Village Dr. San Diego, CA 92161
 
Record
SN05981078-F 20210424/210422230119 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.