SOURCES SOUGHT
99 -- MARFORCYBER � B8605 RENOVATION DB PROJECT, FORT MEADE, MD
- Notice Date
- 4/23/2021 8:38:56 AM
- Notice Type
- Sources Sought
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- W2SD ENDIST BALTIMORE BALTIMORE MD 21201-2526 USA
- ZIP Code
- 21201-2526
- Solicitation Number
- PANNAD-21-P-0000-004076
- Response Due
- 5/8/2021 10:00:00 AM
- Archive Date
- 05/23/2021
- Point of Contact
- Punatoto Taamu, Patricia Morrow
- E-Mail Address
-
Punatoto.V.Taamu@usace.army.mil, patricia.l.morrow@usace.army.mil
(Punatoto.V.Taamu@usace.army.mil, patricia.l.morrow@usace.army.mil)
- Description
- THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR PROPOSAL. THERE WILL NOT BE A SOLICITATION, SPECIFICATIONS, OR DRAWINGS AVAILABLE AT THIS TIME. The U.S. Army Corps of Engineers (USACE), Baltimore District, requests letters of interest from qualified PRIME CONSTRUCTION CONTRACTORS interested in performing work on the design-build project for renovation of Building 8605. By way of this Market Survey/Sources Sought Notice, the USACE Baltimore District intends to determine the extent of capable firms that are engaged in providing the services described below. The responses to this Notice will be used for planning purpose. Therefore, this Notice does not constitute a Request for Proposal (RFP); it does not guarantee the future issue of an RFP; nor does it commit the Government to contract for any supply or service. Further, this Agency will not accept unsolicited proposals. Respondents are advised that this Agency will not pay for any information or administrative cost incurred in response to this Notice; all costs associated with responding to this Notice will be solely at the responding party's expense. At this time, proprietary information is not being requested, and respondents shall refrain from providing proprietary information in response to this Notice. Please be advised that all submissions become Government property and will not be returned. Not responding to this Notice does not preclude participation in any future Solicitation, if any is issued. Responses to this announcement for sources sought will be used by the Government to make appropriate acquisition decisions. Therefore, the type of set-aside decision to be issued will in part depend upon the capabilities of the responses to this notice. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the U.S Government to form a binding contract. It is the responsibility of the interested parties to monitor this site for additional information pertaining to this Notice. PROJECT DESCRIPTION: This project will repair, sustain, and modernize an existing General Administrative Building 8605 that is in a failed or failing condition into a Sensitive Compartmented Information Facility for MARFORCYER located at Fort Meade, MD. The building was built in 1954 as a 39,197 square feet three story barracks with a hammerhead kitchen. The project repairs will increase the building to 43,160 square feet, by the addition of an elevator and stairs. The scope of work includes the following: Architecture: Repair by replacement to existing failed or failing architectural components. Replace all wall, floor and ceiling finishes. Replace all doors, door frames, windows, and hardware. Current building standards and life safety repairs consistent with a major repair project is required. Repair nonfunctional area with new stairs and elevator. Mechanical: Replace all fan coil units, associated dual temperature piping, condensate drain lines, thermostats and controls. An elevator addition is proposed as part of the repairs to serve floors 1-3 w/basement as the pit level. Electrical: Replace all electrical panels, circuit breakers, conduit, conductors, receptacles, switches and lights. Fire Alarm and sprinkler Systems: Replacement all sprinkler Systems, fire alarm system, Mass Notification Systems (MNS) and public address system. Security: Replace all security systems in accordance with ICD/ICS 705. Plumbing: Replace all plumbing fixtures, sinks, vanities, commodes, urinals, urinal screens, toilet partitions, toilet accessories, and associated sanitary lines, vent lines, water lines and valves. Roofing: Replace the failed flat roof with a sloped metal roof and gutter systems. Structural: Building structural systems will be evaluated for strength. Implementation of Progressive Collapse in the design was not needed since there is not significant risk in accordance to UFC 4-010-01 - Paragraph 3-7, DoD Minimum. HAZMAT: If any ACM is found, shall be abated as an integral part of the repair project in accordance to DA Pam 420-11 Para 2-1b. Site Work: Site will be regrading to cause water to flow away from building, include storm water management features, repair by replacement sidewalls, entr�e stairways, fire-fighting apparatus access routing and landscaping. Exterior: Seal the exterior with a Burnt Red Brick system to reduce life cycle maintenance costs and meet the requirements of the Installation Design Guide. Demolition: The project will completely gut the existing building interior. ATFP: Incorporate minimum anti-terrorism force protection (ATFP) measures. Communications: Replace the telephone, data and Local Area Network (LAN) systems. ACQUISITION APPROACH: The proposed project will be a competitive, firm-fixed price, Design-Build (D-B) contract.� CONSTRUCTION MAGNITUDE: In accordance with DFARS 236.204 the magnitude of construction is between $25,000,000 and $100,000,000. RESPONSES TO THIS NOTICE: Responders should address ALL of the following in their submittal: Firm�s name, address, point of contact, phone number, e-mail address, CAGE code and DUNS number. � In consideration of NAICS code 236220, with a small business size standard in dollars of $36.5M, indicate which of the following small business categories your business is classified under: Small Business, Veteran Owned Small Business, Service Disabled Veteran Owned Small Business, Small Disadvantaged Business, Woman-Owned Small Business, HUBZone Small Business, or 8(a) Business. � Indicate if your company is currently prohibited from doing business with the Federal Government. Yes/No. (If yes, explain). � Provide a letter from the surety regarding the bonding capability for a single contract action and aggregate of the interested prime contractor. � Provide at least three (3) example projects similar to the project description above completed by the interested prime contractor in the last five years. Projects shall be no less than $20M. Include point of contact information for the examples provided in order for the Government to verify the past performance on indicated projects. � Responders should have experience in the areas listed below and provide narratives identifying that specific experience: Antiterrorism Force Protection (ATFP) Compliance; UFC Criteria; experience with existing building structural work; experience with Sensitive Compartmented Information Facility (SCIF) design & construction in accordance with ICD/ICS 705; experience with meeting DD Form 254 � Security Requirements; experience with LEED certification of Silver or greater; and experience with Audio/Visual design. The Contractor shall show experience with design-build military construction. � Responders shall possess a Facility Site License (FSL) for facility clearance to handle classified documents to support the design in the DB effort. � The design firm and/or construction company shall be U.S. owned. All personal shall be U.S. citizens (no dual citizenship). Personal is not required to hold a security clearance. Does the Contractor have any constraints with a 1st quarter solicitation vs. a 4th quarter solicitation? � Total submittal shall be no longer than 10 pages in one (1).pdf file. Double sided pages will count as two (2) separate pages. Comments will be shared with the Government project team, but otherwise will be held in strict confidence. SUBMISSION INSTRUCTIONS Interested parties who consider themselves qualified to perform the above-listed requirement are invited to submit a response to this Sources Sought Notice NLT 10:00AM Eastern Standard Time (EST) May 08, 2021. All responses under this Sources Sought Notice must be emailed to, MAJ Puna Taamu, Contract Specialist � Punatoto.V.Taamu@usace.army.mil referencing the sources sought notice number PANNAD-21-P-0000-004076 Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. If you have any questions concerning this opportunity please contact: MAJ Taamu via email � Punatoto.V.Taamu@usace.army.mil.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/050f59295d86413fa65329dc127c6c8a/view)
- Place of Performance
- Address: Fort George G Meade, MD, USA
- Country: USA
- Country: USA
- Record
- SN05982084-F 20210425/210423230114 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |