SOURCES SOUGHT

59 -- Sources Sought for Intelligent Digital Kilo-Watt-Hour and Power Quality Meter as well as an Intelligent Digital Power Quality Meter with Remote Display

Notice Date
4/27/2021 12:21:11 PM
 
Notice Type
Sources Sought
 
NAICS
334515 — Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
 
Contracting Office
NAVAL FAC ENGINEEERING CMD PACIFIC JBPHH HI 96860-3134 USA
 
ZIP Code
96860-3134
 
Solicitation Number
N6274221IDKWHPQM
 
Response Due
5/12/2021 1:00:00 PM
 
Archive Date
05/27/2021
 
Point of Contact
Shaun Bissen, Phone: 8084714666, Erik Torngren, Phone: 8084746476
 
E-Mail Address
shaun.bissen@navy.mil, erik.torngren@navy.mil
(shaun.bissen@navy.mil, erik.torngren@navy.mil)
 
Description
Notice of intent to use a brand name product. The Naval Facilities Engineering Systems Command, Pacific (NAVFAC Pacific) is performing a market survey to determine if other potential sources of supply can provide an Intelligent Digital Kilo-Watt-Hour and Power Quality Meter as well as an Intelligent Digital Power Quality Meter with Remote Display that has equal performance and listing/approval requirements to the Schneider KWHM Model 8650A and Schneider PowerLogic PM5563 & Schneider PowerLogic PM5563 Remote Display respectively. FY21 MCON P-519 X-Ray Wharf Improvements, Berth 2, Naval Base Guam requires three (3) Intelligent Digital Kilo-Watt-Hour and Power Quality Meter as well as twenty (20) Intelligent Digital Power Quality Meters with twenty (20) Remote Displays that have the following characteristics: � Requirements for the Intelligent Digital Kilo-Watt-Hour and Power Quality Meter ANSI Class 0.2 and IEC 62053-22/23 Class 0.2S metering: For interconnection points on medium, high, and ultra-high voltage networks; twice as accurate as current IEC and ANSI Class 0.2 standards over all conditions and including single wide range current measurement. Power quality compliance monitoring: Monitor compliance with international quality-of-supply standards (IEC 61000-4-30 Class A/S, EN50160, IEC 61000-4-7, IEC 61000-4-15, IEEE 1159, IEEE 519). Digital fault recording: Simultaneous capture of voltage and current channels for sub-cycle disturbance transients. Complete communications: Multi-port, multi-protocol ports including serial, infrared, modem and ethernet. Simultaneously supports multiple industry standard protocols including: Itron MV-90, Modbus, Modbus Master, DNP 3.0 and IEC 61850. Multiple tariffs and time-of-use: Apply tariffs, seasonal rate schedules to measure energy and demand values for time periods with specific billing requirements. Multiple setpoints for alarm and control functions: A total of 65 setpoints are configurable for 1-second or � - cycle operation. Power quality summary: Consolidates all the power quality characteristics into a single trend index. Integrate with software: Meters integrate with ION Enterprise operations software or other energy management systems; MV90, DNP, Modbus, IEC 61850. Transformer/line loss compensation: Determine technical system losses in real time. Instrument transformer correction: Improve accuracy by correcting for less accurate transformers. Requirements for the Intelligent Digital Power Quality Meter with Remote Display Complies with standards ANSI Class 0.2 and IEC 62053-22/23 Class 0.2S metering; complies with IEC 61555-12 PMD/S/K70/0.2; IEC 62053-23; IEC 62052-11. Remote Display (96mm X 96mm) consisting of backlit LCD, multilingual, bar graphs, 6 lines, 4 concurrent values 4 selector pushbuttons. Power Quality Analysis of harmonics individually up to 63rd harmonic. Communications: Serial ports with Modbus protocol, Ethernet port with Modbus TCP protocol, Ethernet port with BACnet/IP Protocol with ability to simultaneously communicate via Modbus TCP/IP and BACnet/IP, Ethernet-to-serial gateway, Onboard Web server with Web pages. Capable of being daisy chained together as submeters with the ION 8650A meter as master. Data logging and internal memory up to 14 selectable parameters with configurable interval and duration (e.g. 6 parameters for 90 days at 15-minute intervals). Multiple setpoints for alarm and control functions: A total 29 set points are configurable for 1-second operation; single and multi-condition alarms; Boolean alarm logic. This notification is for market research purposes only to identify if other potential sources of supply can meet the requirements of the Government. This is not a request for proposals, quotes, or an invitation for bid. The intent of this notice is to identify other potential sources of this product. To be considered, please submit detailed technical data in order for the Government to conduct a comprehensive evaluation of your product to ensure compatibility with the existing system. In accordance with FAR 15.201(e), a response to this notice is not an offer and cannot be accepted by the Government to form a binding contract. The responder is solely responsible for the information it submits and any associated costs. The Government reserves the right to disregard any submittal that is incomplete or vague. Please do not submit company brochures. Please submit complete information via email to Mr. Shaun Bissen via electronic mail at shaun.bissen@navy.mil no later 12 May 2021 at 10:00 a.m. H.S.T. Information received after the due date/time will not be considered. Any information provided to the Government in response to this RFI will become U.S. Government property and will not be returned. All proprietary or classified information will be treated appropriately.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/8d91e438f21c4f14b5b7f2f5aa2078ac/view)
 
Place of Performance
Address: GUM
Country: GUM
 
Record
SN05984836-F 20210429/210427230115 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.