Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF APRIL 30, 2021 SAM #7090
MODIFICATION

Z -- Phoenix Indian Medical Center Compressor Replacement

Notice Date
4/28/2021 11:23:36 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
PHOENIX AREA INDIAN HEALTH SVC PHOENIX AZ 85004 USA
 
ZIP Code
85004
 
Solicitation Number
75H71221R00037
 
Response Due
5/13/2021 11:00:00 AM
 
Archive Date
07/01/2021
 
Point of Contact
Jonathan Schrader, Phone: 6023645372
 
E-Mail Address
jonathan.schrader@ihs.gov
(jonathan.schrader@ihs.gov)
 
Small Business Set-Aside
BICiv Buy Indian Set-Aside (specific to Department of Health and Human Services, Indian Health Services)
 
Description
The Phoenix Indian Medical Center uses compressed air to control the mixing boxes in the hospital. One compressor was replaced, this compressor will be the redundant unit to back-up the newly replaced compressor. The objective of this contract is to remove and replace the old compressor with a Chicago Pneumatic QRS-15 (or equal) to match the compressor we just replaced. This will improve the reliability of the pneumatic air control system. One compressor was replaced and we need a redundant unit to make sure the system is reliable. System Requirements - The system shall have the capacity to maintain 150 PSI and have a flow rate of about 50 cfm, the machine is rated at 56.3 cfm at 125 PSI. - A low sound enclosure. - Continuous operating capability. - ASME Receiver Mounted (60 gallon 3-7.5 HP) (120 gallon 10-15HP) - Tri-Voltage TEFC motor, 460 Volt - Vibration Isolated Assembly - Simple Maintenance with spin on oil filter and separator - UL and UL-C approved control panel - Included air dryer The awarded vendor shall be fully responsible for removing and replacing the compressor. The contractor shall also place new conductors from the motor control center to a new disconnect and provide new conduit and flexible ducting to the new unit. The new compressor shall be set up to run on 460 V. The contractor shall also pipe the discharge air from the machine to the existing piping, the contractor will look at the other system to match the piping needed.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/94287f62cb80462e84f63ce41a555b82/view)
 
Place of Performance
Address: Phoenix, AZ 85016, USA
Zip Code: 85016
Country: USA
 
Record
SN05985198-F 20210430/210428230114 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.