Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MAY 07, 2021 SAM #7097
SOLICITATION NOTICE

65 -- Ensite Precision Mapping System (Brand name only) This is not a request for quote

Notice Date
5/5/2021 1:44:49 PM
 
Notice Type
Presolicitation
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
244-NETWORK CONTRACT OFFICE 4 (36C244) PITTSBURGH PA 15215 USA
 
ZIP Code
15215
 
Solicitation Number
36C24421Q0667
 
Response Due
5/14/2021 12:00:00 PM
 
Archive Date
08/12/2021
 
Point of Contact
Allan Tabliago, Contract Specialist, Phone: 215-823-5800 x203443
 
E-Mail Address
allan.tabliago@va.gov
(allan.tabliago@va.gov)
 
Awardee
null
 
Description
THIS IS NOT A SOLICITATION ANNOUNCEMENT. THIS IS A REQUEST FOR INFORMATION ONLY. This Request for Information (RFI) is intended for information and planning purposes only at this time; and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Because this is a Request for Information announcement, no evaluation letters and/or results will be issued to the respondents. No solicitation exists. Therefore, do not request a copy of a solicitation. See Instructions on page 5. Ensite Precision Cardiac Mapping System INTRODUCTION/BACKGROUND: Advanced electrophysiology mapping system creates non-fluoroscopic 3D images of the heart chamber(s) through the use of either EnSite NavX Visualization and Navigation Technology or the non-contact EnSite Array catheter. System provides diagnostic tools which represent the anatomy of the cardiac chamber and electro-anatomical information (e.g. activation maps, voltage maps, CFAE maps, fractionation maps) as well as tracks the real-time location of electrophysiology catheters within the cardiac structure. System also assists in recording the location of ablation lesions as applied by an ablation generator. OBJECTIVE: The VA Pittsburgh Healthcare System, (646) Pittsburgh, Pennsylvania, hereby referred to as the VAMC Pittsburgh (646), is seeking the acquisition of one (1) Ensite Precision Cardiac Mapping System. MAJOR REQUIREMENTS: The Contractor/ Vendor must complete the following tasks to meet the needs of this acquisition: one Ensite Precision Cardiac Mapping System (2) Salient Characteristics Display Workstation with 32 GB RAM, 3.4 GHz dual six-core processors, and Quadro K2200 Graphics running most current version of operating system software. EnSite Amplifier Subsystem, magnetic unit, field frame, mapping software for 3D electroanatomical map creation and additional modules (listed below), RF generator, RF generator remote control, fiber optic light unit for contact force catheter, irrigation pump, fiber optic cables, serial cables, DVI cables, CAT5 cables, power supply units, color inkjet printer, physician and staff training. EnSite Precision Module - hardware EnSite PrecisionTM Link, Sensor EnabledTM EnSite PrecisionTM Field Frame EnSite Precision Module -software EnSite Verismo Creates 3D cardiac chamber models from CT/MR datasets for display on the EnSite Velocity System. EnSite Fusion The EnSite Fusion Registration Module with Dynamic Registration will incorporate a real time model with a segmented CT or MR model to facilitate navigation within the segmented geometry. EnSite Derexi The EnSite Derexi Module consists of software features that uniquely integrate the EP-WorkMate Recording System with the EnSite Precision System. These features consolidate patient and clinical information and reduce the duplicate steps in the workflow. EnSite Courier Imports CT/MR/3D Rotational Angiography cardiac datasets from the PACS server to the EnSite Precision System. Exports segmented 3D models back to the PACS server. Facilitates backup of EnSite Velocity System data to the PACS server. Allows review of case data from an EnSite Velocity System or a remote workstation. EnSite AutoMap The software module allows user to create high density maps with any catheter. Collect data with no point limit. Automatic deletion of points outside user-specific criteria. Automated point inclusion and exclusion criteria include: score threshold for morphology match, cycle length tolerance, catheter speed limit, distance threshold, signal to noise threshold, force. EnSite AutoMark The software module allows for automated lesion marker guidance based on user-defined criteria. Size and color lesion markers based on multiple criteria. Assess ablation catheter stability and AutoMark placement with the AutoTrack feature for automatic recording of precise tip location during RF energy application. System contains Instructions For Use (IFU). Service Coverage: Includes initial one year manufacturer s warranty Anti Fatigue Mat EnSite Contact Force Module Contains: EnSite Contact Force Module v1.0 TactiSys Quartz Allows contact force data to be viewed on the EnSite Velocity Cardiac Mapping System. Key benefits include an intuitive display of contact force data, easier set-up and an enhanced workflow. Service Coverage: Includes initial one-year manufacturer s warranty Ampere Generator Kit Increased efficiency and control - Designed for improved efficiency and decreased noise interference - User controlled Power or Temperature modes Easy to use standard options - Monitor real-time temperature and impedance data on the color LCD screen - Power, temperature, impedance and duration push-button controls - Increased lab efficiency through user presets - Easy bedside physician control with included Footswitch Solutions designed to reduce risk - Select maximum temperature for automatic modulation of power with the TempGuard mode - Manage procedural needs through user-configured variable Power Ramp-Up - Control irrigation flow rates with the Auto Flow feature - Enhanced control of RF delivery with Automatic RF shutoff parameters Seamless integration for the EP Lab Ampere RF generator integrates with our EnSite Velocity System, WorkMate Claris System, Cool Point Irrigation Pump and all other Abbott Laboratories Inc., standard and irrigated ablation catheters. The Ampere software is also upgradable via USB connection. Includes generator and footswitch with 2.5 m cable. Cool Point Irrigation Pump Cool Point Irrigation Pump Includes: Pump, power cord, pole clamp, 1779 communications (connecting) cable, tubing set (1 each) and operator s manual. Communication cable for the Cool Point Irrigation Pump (included with pump). Cool Point Tubing Set (sold individually). Service Coverage: Includes initial one-year manufacturer s warranty The Government and the Contractor understand and agree that the services to be delivered under this contract by the Contractor to the Government are non-personal services and the parties recognize and agree that no employer-employee or master-servant relationships exist or will exist under the contract between the Government and the Contractor s employees. POINT OF CONTACT (POC): The identified POC and technical representative for this acquisition is: Name: Joseph Falcona Phone Number: 412-360-1077 Email: joseph.falcona@va.gov ""No Government personnel, other than the Contracting Officer, have the authority to change or alter these requirements. The COR shall clarify technical points or supply relevant technical information, but no requirements in this scope of work may be altered as a sole result of such verbal clarification."" REPORTS/DELIVERABLES: Delivery confirmation of equipment and commodities will be made through the Logistics Department of the VAMC Pittsburgh (646). This will include documentation of receipt and assignment of a facility based EE number for identification and tracking purposes. Delivery confirmation of non-equipment/ commodities acquisitions is the responsibility of the receiving Facility and/ or Service. Request for Information Instructions The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above. Responses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, DUNS Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 334510 (size standard of 1250 employees). Please answer the following questions: Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? Is your company considered small under the NAICS code identified under this RFI? Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? If not, can you provide additional information shown below. This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers. Does your company exceed 500 employees; Primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied; Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice; Obtained an individual or class waiver? If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontract work and completion of job. Does your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number. If you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. Please submit your capabilities in regard to the salient characteristics detailed above and any information pertaining to equal to items to establish capabilities for planning purposes? Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A. Please provide your DUNS number. This RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 13. Telephone responses will not be accepted. Responses must be received via e-mail to allan.tabliago@va.gov no later than, 03:00 PM Eastern Standard Time (EST) on May 14, 2021. This notice will help the VA in determining available potential sources only. Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action. All questions will be addressed by the Contracting Specialist, Allan Tabliago. All firms responding to this Request for Information are advised that their response is not a request for proposal, therefore will not be considered for a contract award. If a solicitation is issued, information will be posted on the beta.sam web site for all qualified interested parties at a later date and interested parties must respond to the solicitation to be considered for award. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information. Information will only be accepted in writing by e-mail to Contracting Officer at allan.tabliago@va.gov. DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. GSA has determined unit prices to be fair and reasonable FAR subpart 8.404(d) End of Document
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/129842bb6ea94317adc91b6716385460/view)
 
Place of Performance
Address: VA Pittsburgh HCS Univeristy Dr C, Pittsburgh 15240, USA
Zip Code: 15240
Country: USA
 
Record
SN05992805-F 20210507/210505230117 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.