43 -- Dual Pump Condensate Tank Unit Replacement/Installation

Notice Date
5/7/2021 9:11:25 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
333912 — Air and Gas Compressor Manufacturing
 
Contracting Office
PHOENIX AREA INDIAN HEALTH SVC PHOENIX AZ 85004 USA
 
ZIP Code
85004
 
Solicitation Number
IHS1425524
 
Response Due
5/18/2021 8:00:00 AM
 
Archive Date
06/02/2021
 
Point of Contact
Phillip Wendzillo, Phone: 6023645015
 
E-Mail Address
phillip.wendzillo@ihs.gov
(phillip.wendzillo@ihs.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
REQUIREMENTS:� Indian Health Service (IHS) � Phoenix Area Office (PAO), 40 North Central Ave., Phoenix, Arizona 85004-4424 The contractor shall procure and install a new dual pump steam condensate collection and return system to include the dual pumps, collection tank, inlet strainer, control system, and all connections required to operate. The contractor shall install the new system in the same footprint as the existing system. The contractor shall provide all plant, labor, materials, transportation, equipment, and supplies required to complete the requirements outlined below. The contractor shall verify all locations and quantities. Procurement: The contractor shall procure a �Domestic Series CBE Condensate Unit Model 36CBE30-30� and associated system components. The system shall include dual pumps, collection tank, control panel, basket strainer, gauge glass, discharge butterfly valve, lifting eye, welded steel stand, discharge pressure gauge assembly, ball valves, gate valves, check valves, pressure switches, flow switches, couplers, nipples, tee�s, unions, and galvanized piping. Removal: The contractor shall provide all the necessary tools and equipment required to remove the existing dual pump condensate system to include dual pumps, collection tank, control panel, and associated components from the existing footprint/concrete foundation. The contractor shall electrically and mechanically isolate the compressor utilizing their lockout/tag out procedures. The contractor shall remove the existing system and associated components from the site and dispose of in accordance with regulatory requirements. Interim Functionality: The contractor shall ensure the domestic hot water system remains operational during the removal of the existing system and installation of the new system. When the system is being removed and installed, the condensate shall be diverted to a drain location 6� down to the adjacent utility tunnel floor and 50� down the utility tunnel. Installation: The contractor shall provide all necessary tools and equipment required to install the system. The contractor shall install the new dual pump steam condensate collection and return system in the same footprint as the existing compressor system. The contractor shall replace all the existing �� ball valves, 1� & 2� gate valves, 2� check valves, pressure switches, flow switches, couplers, nipples, tee�s, unions, and galvanized piping.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/cf820077fff845a8835df2c130e168e3/view)
 
Place of Performance
Address: Whiteriver, AZ 85941, USA
Zip Code: 85941
Country: USA
 
Record
SN05995366-F 20210509/210507230114 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.