Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JUNE 04, 2021 SAM #7125
SOLICITATION NOTICE

65 -- Stryker Power Load System

Notice Date
6/2/2021 11:24:07 AM
 
Notice Type
Presolicitation
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
257-NETWORK CONTRACT OFFICE 17 (36C257) ARLINGTON TX 76006 USA
 
ZIP Code
76006
 
Solicitation Number
36C25721Q0958
 
Response Due
6/2/2021 2:00:00 PM
 
Archive Date
06/12/2021
 
Point of Contact
Dr. Vinicky Ann Ervin Ph.D., Contract Specialist, Phone: Please place in email Subject Title as follows:, Fax: 36C25721Q0958 Power Load System
 
E-Mail Address
vinicky.ervin@va.gov
(vinicky.ervin@va.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Awardee
null
 
Description
General Requirements: Brand name or equal Power Load System are needed for the Temple, TX in accordance with the following requirements: Q&A Wednesday Jun 2- Friday Jun 4 1 PM CST Quote Due Wednesday 9 Jun 2021 4 PM CST. ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 3.00 EA $00.00 $00.00 MTS POWER LOAD LOCAL STOCK NUMBER: 639005550001 0002 3.00 EA $00.00 $00.00 6506 MTS PWRPRO COT HIGH CNFIG LOCAL STOCK NUMBER: 650605550003 0003 3.00 EA $00.00 $00.00 ProCare Power-PRO Prevent Service: Annual onsite prevention maintenance inspection and unlimited repairs including parts, labor and travel with battery coverage for Power-PRO XT LOCAL STOCK NUMBER: 71061PT 0004 3.00 EA $00.00 $00.00 ProCare Power-LOAD Prevent Service: Annual onsite preventive maintenance inspection and unlimited repairs including parts, labor and travel with battery coverage for MTS POWER LOAD LOCAL STOCK NUMBER: 76011PT GRAND TOTAL $00.00 Item Name: Power-Load Salient Characteristics: IPX6: The system is tested to withstand powerful water jets (IEC 60601-1 and IEC 60601-1-2) Conforms to industry standards for mechanical and electrical safety for medical electrical devices, as well as electromagnetic compatibility and immunity, BS EN-1789:2007 clause 4.5.9, when used with Power-PRO Cot and X-Restraints This is a dynamic crash test which subjects a 50th percentile dummy to nominal 10g deceleration for a minimum of 50ms. Following the test there shall be no sharp edges and SAE J3027 compliant when used with Stryker s Power-PRO Cot and X-Restraints provide a linear guide for loading and unloading the cot remote actuation from Power-PRO foot end controls Engages to the cot during loading and unloading, providing a means of lifting and lowering Safe working load of 870 lb and capable of lifting patients weighing up to 700 lbs. Mounts inside the patient compartment to prevent environmental exposure and corrosion Power washable and inductively charges Stryker s SMRT Battery. Item Name: Power-Pro XT Cot Salient Characteristics: IPX6: The system is tested to withstand powerful water jets (IEC 60601-1 and IEC 60601-1-2) Conforms to industry standards for mechanical and electrical safety for medical electrical devices, as well as electromagnetic compatibility and immunity, BS EN-1789:2007 clause 4.5.9, when used with Power-PRO Cot and X-Restraints This is a dynamic crash test which subjects a 50th percentile dummy to nominal 10g deceleration for a minimum of 50ms. Following the test there shall be no sharp edges and SAE J3027 compliant when used with Stryker s Power-PRO Cot and X-Restraints provide a linear guide for loading and unloading the cot remote actuation from Power-PRO foot end controls Engages to the cot during loading and unloading, providing a means of lifting and lowering Safe working load of 870 lb and capable of lifting patients weighing up to 700 lbs. Mounts inside the patient compartment to prevent environmental exposure and corrosion Power washable and inductively charges Stryker s SMRT Battery. Manual release handle for unloading that uses hydraulic dampening to prevent abrupt jarring to the patient or operator battery is placed at the foot end of the stretcher cot legs power-retract in 3.5 seconds which speeds load time cot load height of 36 and is operator adjustable to match the deck height of individual ambulances foot-end of the cot provides lifting bars and operator controls at two different heights, thus providing optimal ergonomics to most operator heights The foot end of the cot contains a large battery indicator light which displays amber or green which indicates battery level A warning is given by a flashing amber light, providing the operator the time to change the battery before full depletion of power has 6 x 2 sealed casters and bearings foot end mounted hourly usage meter powder-coating of the aluminum frame (including the patient handling surfaces) and sealed caster bearings, thus reducing aluminum oxidation throughout the cot power washable The Department of Veterans Affairs is seeking both manufacturers and/or distributors of the exact match or functionally equivalent equipment/ services to the following listed above Stryker Power Load System. 52.211-6 Brand Name or Equal. As prescribed in 11.107(a), insert the following provision: Brand Name or Equal (Aug 1999)       (a) If an item in this solicitation is identified as brand name or equal, the purchase description reflects the characteristics and level of quality that will satisfy the Government s needs. The salient physical, functional, or performance characteristics that equal products must meet are specified in the solicitation.       (b) To be considered for award, offers of equal products, including equal products of the brand name manufacturer, must-            (1) Meet the salient physical, functional, or performance characteristic specified in this RFI.            (2) Clearly identify the item by-                 (i) Brand name, if any; and                 (ii) Make or model number.            (3) Include descriptive literature such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the Contracting Officer; and            (4) Clearly describe any modifications the offeror plans to make in a product to make it conform to the solicitation requirements. Mark any descriptive material to clearly show the modifications.       (c) The Contracting Officer will evaluate equal products on the basis of information furnished by the offeror or identified in the offer and reasonably available to the Contracting Officer. The Contracting Officer is not responsible for locating or obtaining any information not identified in the offer.       (d) Unless the offeror clearly indicates in its offer that the product being offered is an equal product, the offeror shall provide the brand name product referenced in the solicitation. (End of clause) VAAR 852.212-72 Gray Market Items: a) Gray market items are Original Equipment Manufacturers' (OEM) goods sold through unauthorized channels in direct competition with authorized distributors. This procurement is for new OEM medical equipment only for VA Medical Centers. No remanufactures or gray market items will be acceptable. (b) Vendor shall be an OEM, authorized dealer, authorized distributor or authorized reseller for the proposed equipment/system, verified by an authorization letter or other documents from the OEM, such that the OEM's warranty and service are provided and maintained by the OEM. All software licensing, warranty and service associated with the equipment/system shall be in accordance with the OEM terms and conditions. (End of clause) FAR 52.212-2 Evaluation-Commercial Items: A copy of the authorized distributor letter from the contractor to verify that you are an authorized distributor of the products/services SHALL BE SUBMITTED WITH THE QUOTE AND IS MANDATORY. Please title email with RFQ Solicitation Number and Name Power Load System
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/5c372bd16cb84d82909cc541afa1107b/view)
 
Place of Performance
Address: Olin E. Teague Veterans' Medical Center 1901 Veterans Memorial Drive, Temple, TX 76504, USA
Zip Code: 76504
Country: USA
 
Record
SN06019505-F 20210604/210602230121 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.