Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JUNE 13, 2021 SAM #7134
SOURCES SOUGHT

65 -- Automatic Blood Pressure Monitors for Home-Use

Notice Date
6/11/2021 1:46:08 PM
 
Notice Type
Sources Sought
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
COMMODITIES & SERVICES ACQUISITION SERVICE (36C791) DENVER CO 80225 USA
 
ZIP Code
80225
 
Solicitation Number
36C79121Q0005
 
Response Due
7/2/2021 2:00:00 PM
 
Archive Date
08/31/2021
 
Point of Contact
Chris Binkley, Contract Specialist, Phone: TBD
 
E-Mail Address
christopher.binkley@va.gov
(christopher.binkley@va.gov)
 
Awardee
null
 
Description
Page 5 of 5 This RFI is issued solely for information and planning purposes only and does not constitute a Request for Quote (RFQ)/Invitation for Bid (IFB)/Request for Proposal (RFP). This notice does not commit the U.S. Government to contract for any supply or service. Furthermore, the U.S. Government is not seeking quotes, bids or proposals at this time and will not accept unsolicited proposals in response to this Request for Information. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. Submittals will not be returned to the responder. Please submit your company s capabilities statement and completed vendor responses electronically to Ms. Star Yeo at star.yeo@va.gov AND Mr. Chris Binkley at christopher.binkley@va.gov no later than July 02, 2021 at 3:00 p.m. Mountain Daylight Time (MDT). Please include your company name in the subject of the email response as: Attention: Automatic Blood Pressure Monitor RFI VENDOR NAME HERE . Title: Sources Sought Notice for Automatic Electronic Blood Pressure Monitors for Home-Use, hereinafter called Blood Pressure Monitors, and Associated Items in support of the Department of Veterans Affairs. The Department of Veterans Affairs (VA), Commodities & Services Acquisition Service (CSAS) is seeking information from vendors regarding the availability and business practices regarding the procurement of Blood Pressure Monitors and Associated Items. Please provide requested information using the below stated Minimum Technical Requirements (MTR) for the response to the VA. Additionally, address the Business Size Classification of the vendor interested (SDVOB, 8(a), SDB, Hub, WOSB, EWOSB, Small, or Other). The qualifying NAICS code for this effort is 339112, Surgical and Medical Instrument Manufacturing, and employee size standard is 1000 employees. Minimum Technical Requirements and Functions: The minimum technical requirements and functions for Blood Pressure Monitors listed below can be updated because of VA need or due to responses to this RFI. Please address Brand Name, Model Number and Part Number and origin of manufacturing. Automatic Electronic Blood Pressure Monitor for Home Use shall include the monitor and cuff: Monitor Technical Functions Back Lit LCD or LED read out window displays systolic and diastolic blood pressures in mmHg with pulse rate in beats per minute (BPM) Numbers must be easily viewable via VVC or other telehealth technology Readout number must be at least 1 inch Pressure rating indicator with normal slightly elevated elevated using the AHA recommendations Irregular heartbeat indicator Unit has a memory function and can store and retrieve at least 60 readings Memory must record date and time stamp each result One (1) button start and stop Should support Bluetooth Core Specification Version 4.0 Monitor should be clinically validated by an independent organization. Blood pressure measurements determined with device are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultation method within the limits prescribed by the American National Standards Institute (ANSI/AAMI SP10) for electronic sphygmomanometers Average reading feature Cuff Technical Functions Cuff Technical Functions Arm cuff must be well marked with a symbol for placing sensor on the brachial artery Proper fit range indicator and cuff size is imprinted on the cuff Small Cuff (fits arms approximately 18 to 23 cm) Indicate size of offered item Standard/Adult Cuff (fits arms approximately 23 to 31 cm) Indicate cuff size of offered item Large Cuff (fits arms approximately 35 cm to 44 cm) Indicate cuff size of offered item Extra Large Cuff (fit arms approximately 43 cm to 52 cm) Indicate cuff size of offered item Arm cuff sizes (small, medium, large, and extra-large) must fit user arm circumferences from 18 cm to 52 cm Cuffs and tubing shall be Latex free Automatic wrap cuff or intelliwrap Other Attributes Must include carrying case Copy of 510(k) Premarket Notification Approval Instruction Manual for each Blood pressure monitor, and cuff offered. Must be written in English and Spanish and typestyle minimum of 10 or 11 Provide Toll-Free 800, 855, or 866 Customer Service number Blood Pressure Monitor must be both AC Port with adapter and battery operated and include all batteries required to operate the unit Please address the following: Corporate information Provide your company s contact information (Company name, address, Point of contact name and email). Indicate whether your business is a Small Business (SB) or Large Business (LB). If small, indicate if your firm qualifies as a small, emerging business, or small disadvantaged business. If disadvantaged, specify the disadvantaged group of Service Disables Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), 8(a), HUBZone, Woman Owned Small Business (WOSB). Include the DUNS number of your firm. State whether your firm is registered with the System for Award Management (SAM) at http://www.sam.gov and/or the VetBiz Registry at http://vip.vetbiz.gov. *NOTE: any future solicitation can only be awarded to a contractor who is registered in SAM; to receive award based on VOSB or SDVOSB status, you must be registered and certified in the VetBiz Registry. Is your business the Manufacturer of the product or a Dealer/Distributor? General Information Can replacement cuffs be ordered separately from the Blood Pressure Monitor? Are the products you offer Trade Agreements Act (TAA) compliant? Are there supply chain issues with the unit as a whole or with individual components that would hinder prompt fulfillment? Are there alternative products available for providing Blood Pressure Monitoring for patients who cannot use an Arm Cuff? Provide product information, including product specifications and whether they are commercially available and length of time they have been in use. What are your products lead time? Upon order, how long does it take to receive from the manufacturer (if not the manufacturer), prepare, and be ready to ship? Please provide any additional considerations in the category of Blood Pressure Monitors and any additional information you would like the VA to consider when developing the specifications for this proposed contract. The Government will use responses of this notice to make appropriate acquisition decisions upon review of documentation. a request for proposals may be issued to the government wide point of entry Contract Opportunities (www.sam.gov). Responses to this Sources Sought Notice are not considered adequate responses to any corresponding solicitation announcement. Not responding to this notice does not preclude participation in any future RFQ or IFB or RFP, if any is issued. If a solicitation is released, it will be synopsized on the Government-wide Point of Entry. It is the responsibility of potential offerors to monitor the Government-wide Point of Entry for additional information pertaining to this requirement.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/fc729c53b0d1438cb5a4ba1add3295f7/view)
 
Record
SN06029829-F 20210613/210611230116 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.