65 -- Anesthesia Machine and Monitors

Notice Date
6/16/2021 3:36:05 PM
 
Notice Type
Presolicitation
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
248-NETWORK CONTRACT OFFICE 8 (36C248) TAMPA FL 33637 USA
 
ZIP Code
33637
 
Solicitation Number
36C24821Q1135
 
Response Due
6/18/2021 4:00:00 PM
 
Archive Date
07/28/2021
 
Point of Contact
Tonya Bradley, Contract Specialist, Phone: 407-646-4013
 
E-Mail Address
tonya.bradley@va.gov
(tonya.bradley@va.gov)
 
Awardee
null
 
Description
Sources Sought Notice only. This is neither a solicitation nor a request for quote (RFQ) and does not obligate the Government to award a contract. Request for a solicitation will not receive a response. The Government will not pay nor reimburse any costs of preparing this response. The purpose of this sources sought notice is for market research to make the appropriate acquisition decisions and to gain knowledge of potential qualified and their Small Business Administration (SBA) size classification in relation to North American Industry Classification System (NAICS) 339112, Surgical and Medical Instrument Manufacturing, size standard of 1,000 Employees. The Network Contracting Office (NCO) 08, Orlando Veterans Affairs Healthcare System is seeking a source to provide an Anesthesia Machine and Monitors to the Department of Veterans Affairs Orlando VA Healthcare System, 13800 Veterans Way, Orlando, FL, 32827. The Government intends to award a single, firm fixed price contract and the period of performance is for a one time order. Seeking qualified businesses to provide the following: The contractor shall deliver the following item Brand Name or Equal: Anesthesia machine Apollo components to include: Main features: suitable for low and minimal inhalation anesthesia, adult, pediatric and neonatal patients, precise, electrically driven ventilator requiring no driving gas, mechanically controlled fresh-gas deli and **Country-specific features** Target country: USA Standard floor unit SW version 4.53 * Non-consumptive gas module 3 Gas - O2 / AIR N2O CLIC adapter For using the CLIC absorber on the anesthesia workstation ** Gas connection ** (d) Dräger Auto Exclusion, 3 vap. ** Gas connection ** (e) Press.red. O2, small, CGAV-1 Press.reducer N2O f.s.cylind. ** Cyl.holder & press reg. (f) Press.red. N2O, small, CGAV-1 Press.reducer AIR f.s.cylind. ** Cyl.holder & press reg. (g) Press.red. AIR, small, CGAV-1 (h) SW Advanced Views to include: new mini trend display, new parameters for #MVCO2, #02 uptake, #PEEP/Cpat (i) AF + enh. Ventilation + Monitoring Software option package Autoflow + Advanced Ventilation + Advanced Monitoring and Spirolog (j) Dräger AGS (k) AGS transfer hose, 1.0 m (l) Endotrach (m) Endotr, suction swivel arm (n) Writing tray, Dimensions: approx. 21.6 inch x 15.7 inch (width x depth) (o) Apollo w/options Total Care (p) Power cable 10A 0.75m gy RoHS (q) Kit power outlet strip (r ) Halogen lamp 12V (s) Halogen lamp holder (t) Hose ASM-02 DISS HAND 15L (u) Hose ASM-N2O DISS HAND 15L (v) Hose ASM-AIR DISS HAND 15L (w) Hose ASM-VAC DISS HAND 15L (x) Hose ASM-WAGD HAND DISS N 15L (y) Vapor 2000 (z) D-Vapor (aa) Arm Extension (bb) GCX Channel 7in Salient Characteristics: The device must be a continuous-flow anesthetic machine, which provides a steady flow of air containing a regulated supply of gas while also monitoring important vital signs of the patient to ensure quality and safety. Compatibility 200 W ; Operating Voltage 100 to 127 VAC (- 15 % + 10 %) 45 65 Hz Dimensions 59 × 33.5 × 31.5 inches (150 × 85 × 80 cm) Weight 365 lbs. (165 kg) Industry Standard N/A Governing Body or Organization N/A Complete generic identification Front Lighting control (dimmer) location 12 Central brake 2 Screen with user interface 13 Footrest 3 Rotary knob 14 Drawers (2) (for storage) 4 Fresh-gas flow controls: O2, Air, N2O 15 Anesthetic gas receiving system AGS (optional) 5 Mains power switch 16 Endotracheal aspiration system (optional) 6 Total flow meter 17 Flexible breathing bag arm 7 O2 flush button O2+ 18 Auxiliary oxygen flow meter 8 Writing table 19 Water trap with sample line connection 9 Breathing system 20 Vaporizer units with interlock system (optional) 10 Release button for ventilator module 21 Auxiliary AC outlet (for Desflurane vaporizer) 11 Absorber (optional: disposable CLIC absorber) 22 Top shelf (for external monitors) Rear 1 Auxiliary outlet panel 2 Cylinder tank yoke bar 3 Filter for fan 4 Type plate 5 Scavenging nozzles 6 Cylinder support bar 7 AC power connector 8 Gas supply block 9 Connector for optional halogen lamp (remove cap before use). Use the lamp specified in the list of accessories only. 10 Connectors (3) for backup gas cylinder pressure sensors (covered; access from behind gas supply block) 11 Interface panel Applicable model/make/catalog number OPC5280 Manufacturer name Drager, Inc. Anesthesia Monitors Patient Information Center iX Expand New Add On or Expand PIC iX Enterprise Link Pro Rev C PIC iX Software Release C IntelliVue MX800 USE IntelliVue X3 CBL OR 5-Lead ECG Trunk Cable, AAMI/IEC CBL 5 Leadset, Grabber, AAMI, ICU Dual IBP Adapter Adult NIBP Air Hose 3.0m rainbowSET 10' Cable For LNCS Thermal Array Recorder Module Temperature Parameter Module Invasive Blood Pressure Module Analog Output for Balloon IntelliBridge EC10 Module IntelliBridge EC5 ID-Module Hook: VHM, M-Series, 4 Hook VHM-PL: MX600-850, SA Facilities Implem Solutions Installation Site Services WMTS registration services Project Management Services Clinical Config. & Impl. Services (CMS) Salient Characteristics: MX800 Monitor Essential/significant physical, functional, or performance characteristics. Compatibility 100-240 VAC Dimensions 47.8 x 36.4 x 15.2 (18.8 x 14.3 x 6) Weight (22 kg) Industry Standard 12-lead ST-segment, anesthetic gas, BIS, CCO, CO, CPP, ECG/HR, EEG, IBP, multilead arrhythmia, NIBP, OxyCRG, PPV, PR, QT, QTc, respiration, sidestream/ mainstream/ microstream ETCO2, spirometry, SpO2, SvO2, tcpO2/tcpCO2, temperature, traditional and derived 12-lead ECG, wedge. Governing Body or Organization FDA Complete generic identification Remote viewing via XDS; system features integrated iPC (medical-grade PC) to allow continuous operation in patient vicinity; iPC uses Windows 10 or XP to host a variety of applications (e.g., iSite clients or application launch pad, third-party applications, or hospital owned and developed software); iPC safely shares main display with MX800 (single display setup) and/or is used with standard or medical-grade display (dual display setup); iPC supports displays with or without touch operation; iPC has 6 USB 2.0 ports (5 at rear and one at the side of the monitor) supporting high-speed mode for computer peripherals; MX800 monitors offer comprehensive range of measurements; functionality can be extended by connecting Philips plug-in modules; MX800 monitors are available as stand-alone or networked solutions; modular design allows added capabilities for future requirements. Applicable model/make/catalog number 865240_NAM Manufacturer name Phillips Interested parties may respond by submitting a qualifications letter to include the following information: Company Name Address Point of Contact Phone, Fax, and Email DUNS Number Authorized Distributor Letter Capability Statement specific to the technical requirements. This must not be a generic line card but something that the government can positivity use to determine the procurement strategy of this requisition. Socio-Economic Category (i.e., SDVOSB, VOSB, HUBZone, etc...) Contract Number, if applicable Provide verification that your firm can prove the requested item(s) to include past and/or current contract for the same requirements and any other convincing evidence to help the Government determine your company s capabilities. To be eligible for award, prospective offerors must be registered in the System for Award Management (SAM) Internet Site, www.sam.gov. Responses to this notice shall be sent to via email, no later than 7:00PM Eastern Daylight Time on June 18, 2021. Telephone and facsimile responses will not be considered. Responses shall be submitted via email only to Tonya.Bradley@va.gov. When responding via email ensure the subject line is titled with RFI# 3624821Q1135 Anesthesia Machine and Monitors for the Orlando VA Healthcare System. If a solicitation is issued it will be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this announcement. Responses to this sources sought is not a request to be added to a prospective offerors list or to receive a copy of the solicitation. Questions concerning this announcement should be directed to the Contract Specialist using the e-mail address provided. No other information is available at present time. Thank you for your interest and time to prepare and submit a response.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/5b07c9f96888411b913685152f3500ff/view)
 
Place of Performance
Address: Department of Veteran Affairs Orlando VA Healthcare System 13800 Veterans Way, Orlando 32827
Zip Code: 32827
 
Record
SN06033970-F 20210618/210616230123 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.