J -- Whiteman AFB 6th Year Fire Extinguisher Maintenance

Notice Date
6/23/2021 3:13:24 PM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
811310 — Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
 
Contracting Office
FA4625 509 CONS CC WHITEMAN AFB MO 65305-5344 USA
 
ZIP Code
65305-5344
 
Solicitation Number
FA462521Q1056
 
Response Due
6/29/2021 8:00:00 AM
 
Archive Date
07/14/2021
 
Point of Contact
2d Lt Kedzie, Phone: 6606872370
 
E-Mail Address
wiktor.kedzierzawski.1@us.af.mil
(wiktor.kedzierzawski.1@us.af.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
This is Amendment 0001 to solicitation FA462521Q1056.� The purpose of this amendment is to: 1.� Extend quote due date to 29 June 2021, 10:00 AM CDT 2.� Add Attachment 7, Progress Schedule Questionnaire, as a required element of quote submission.�� 3.� Revise Attachment 1, PWS, par. 3.4, by adding clarifying information (no more than�31 extinguishers may be serviced at a time).� Quoters are reminded to acknowledge this amendment in Attachment 4, Price Schedule and Acknowledgment.� Amendment Posting Date is 23 June 2021. //PREVIOUS// NOTE:� This requirement has changed since the Sources Sought (FA462521N1001).� Notably, a pressure leak test is required instead of visual inspection (see TCTO 13F4-4-501C) and the completion date was adjusted to 8 November 2021.�� See attachments.� The Contractor shall provide all labor and parts required to conduct a 6-year maintenance on 131 halon fire extinguishers (Amerex 150 lb. Wheeled Stored Pressure Halon 1211 Extinguisher Model 600), including a Low Pressure Leak Test on the solder found at the joint connecting the Down Tube, Valve Assembly, and add NSN 4210-01-044-1429 to the Inspection criteria.� The Low Pressure Leak Test removes the need for visual inspection and uses a low-pressure test to determine serviceability of the soldered joint.� All fire extinguishers shall be inspected and maintained in accordance with (IAW) the National Fire Protection Association standard titled ""Portable Fire Extinguishers"", NFPA-10 and the requirements of local authorities having jurisdiction.� The work shall be performed IAW TO 13F4-4-121, TCTO 13F4-4-501, and TCTO 13F4-4-501C�(Note: TCTO 13F4-4-501C supplements, and is used in conjunction with, TCTO 13F4-4-501).� All work shall be accomplished NLT 8 November 2021. //PREVIOUS//
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/cb3cf01d6d19421ebad49fab5dad2417/view)
 
Place of Performance
Address: Whiteman AFB, MO 65305, USA
Zip Code: 65305
Country: USA
 
Record
SN06039919-F 20210625/210623230107 (samdaily.us)
 