SOLICITATION NOTICE
Z -- Reverse Osmosis System Upgrade 610A4-21-513
- Notice Date
- 6/29/2021 6:11:14 AM
- Notice Type
- Solicitation
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- 250-NETWORK CONTRACT OFFICE 10 (36C250) DAYTON OH 45428 USA
- ZIP Code
- 45428
- Solicitation Number
- 36C25021B0031
- Response Due
- 6/28/2021 8:00:00 AM
- Archive Date
- 07/28/2021
- Point of Contact
- Robin L Fletcher, Contract Specialist
- E-Mail Address
-
Robin.Fletcher@va.gov
(Robin.Fletcher@va.gov)
- Awardee
- null
- Description
- Description of purpose work nature and volume: Contractor shall provide all needed labor, materials, to upgrade the Reverse Osmosis system for Sterile Processing to meet AAMI TIR34 Water for Sterile Processing Specifications at the VA Northern Indiana Health Care System Fort Wayne Campus located at 2121 Lake Avenue, Fort Wayne, IN 46805. SPECIFIC: To include: Triple 20 Final Ultrafilters for Bacteria/Endotoxin Removal Triple 20-inch housings/filters Inlet and outlet pressure gauges and sample ports Return Flowmeter Manifold Includes flowmeter and back pressure relief valve to adjust loop velocity Includes loop return sample port and temperature gauge Includes internal return sprayball Tank Vent Filter Assembly with filter 10-inch housing assembly 10-inch Hydrophobic Vent Filter to allow tank to filter air Audible Remote Alarm Assembly To be wired into your Conductivity Monitor to alarm if water quality is below set point. Wiring to be run by others if audible being installed outside of water room through ceiling Ozone Fittings To be installed in storage tank and on outgoing loop for ozone sanitization of loop and tank Installation of RO return line Connect to existing RO supply line above laboratory sink in room 618 and route to existing RO storage tank in room 49C. Pipe material and fittings will be IPEX high purity pipe and fusion weld fittings Provide and install ball valves at each end of new return line Penetrations thru walls and firestopping of same Grundfos VFD pump, 460v, 10gpm@60psi Equipment installation, Loop sanitization with Ozone and Start up Work may require to be performed after hours or weekend The magnitude of construction project is estimated between $25,000 and $100,000. Location of the work: All work to be performed, according to the drawings and specifications, at the Northern Indiana Health Care Systems Fort Wayne Campus, 2121 Lake Avenue, Fort Wayne, Indiana 46805. Tentative dates for issuing invitations, opening bids, and completing contract performance; The Invitation for Bids (IFB) should be posted on/about 03/24/2021 and the Bid Opening should be within 30-45 days thereafter. After award, Contractor will have 21 days from the receipt of Notice to Proceed to complete all work, to include checklist items, controls installation and configuration, testing and balancing, painting, site cleanup and equipment disposal, etc. Plans will be available for inspection without charge: The specification and drawings will be available with the IFB when released. Date by which requests for the invitation for bids should be submitted: Requests for the IFBs should be submitted on/before 03/24/21 at 11:00 A.M. EST. Set-Aside: 100% Total-Set aside for SDVOSB concerns. Amount to be charged for solicitation documents: Not Applicable.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/6d18de174ed94126b45f09c91db4180e/view)
- Record
- SN06046165-F 20210701/210629230149 (samdaily.us)