SOLICITATION NOTICE
66 -- Combined mass spectrometer and flash chromatography system
- Notice Date
- 7/1/2021 11:25:36 AM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- NATIONAL INSTITUTES OF HEALTH NIDA Bethesda MD 20892 USA
- ZIP Code
- 20892
- Solicitation Number
- 75N95021Q00270
- Response Due
- 7/12/2021 9:00:00 AM
- Archive Date
- 07/27/2021
- Point of Contact
- Andrew Varley, Phone: 3014436677, Fax: 3014437595, Polina Klimenkova, Phone: 3018276848
- E-Mail Address
-
andrew.varley@nih.gov, polina.klimenkova@nih.gov
(andrew.varley@nih.gov, polina.klimenkova@nih.gov)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- The purpose of this acquisition is to procure (1) one mass spectrometer and flash chromatography� system for the real-time analysis of compounds designed and synthesized for the study and treatment� of drug of abuse. The requested chromatography system must satisfy the following requirements: 1. � Integrated ELSD component to detect compounds. 2. � Maximum dimensions Flash Chromatography: 26.8 x 14.1 x 17 inches (66 x 36 x 43cm); must� operate in a fume hood. 3. � Maximum dimensions Mass Spectrometer: 26� x 11� x 22 inches (66 x 28 x 56cm); 4. � The small molecule mass spectrometer must easily interface with the flash chromatography� system to add mass direct fractionation to the purification of novel compounds synthesized by� chemists in the laboratory. 5. � The instrument must automatically switch between positive and negative ionization modes� throughout the run and include a fluid interface module to remove sample and redirect t mass spec� for analysis. 6. � The mass spec must include the following: full mass spectra data on any fraction tube, must� automatically clean mass spec interface, must have multiple ionization settings, an option for� multiple peak detection settings of an individual sample, capable of probe wash and cone cleaning after each run, and single point of control of all mass spectrometer and 2 flash parameters. 7. � Users must have the ability to manually inject for pre-purification verification. 8. � ESI (electrospray ionization) is required for polar, ionizable, and acidic/basic compounds. 9. � The software must be user friendly and compatible between systems. The Signal to Noise ratio� shall be increased, faster scan speed, and updated fluid interface decreasing pulsation during runs� and improving signal trace. 10. Warranty against defects in material or workmanship. Instrument found to be defective during� the warranty period will be repaired or replaced by the factory designated service center at no� charge to the Government. A longer warranty is considered more desirable by the Government. 11. The selected contractor will also be required to provide installation and training. No� government furnished equipment or supplies will be provided to the selected contractor for� installation or training. Installation and training shall be coordinated with the technical� end-user, who will be identified in the purchase order, and be conducted during normal business hours (excluding Federal Holidays). �
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/1f3be4dc1a8a4633822f659e06116eb4/view)
- Place of Performance
- Address: Rockville, MD 20850, USA
- Zip Code: 20850
- Country: USA
- Zip Code: 20850
- Record
- SN06049690-F 20210703/210701230120 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |