SPECIAL NOTICE
66 -- 66--FLOUROMETER SENSORS
- Notice Date
- 7/7/2021 2:39:22 PM
- Notice Type
- Special Notice
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- OFFICE OF ACQUISITON GRANTS SACRAMENTO CA 95819 USA
- ZIP Code
- 95819
- Solicitation Number
- 140G0321Q0149
- Response Due
- 7/13/2021 1:00:00 PM
- Archive Date
- 07/28/2021
- Point of Contact
- Allan-Loucks, Dana, Phone: 916-278-9344
- E-Mail Address
-
dallan-loucks@usgs.gov
(dallan-loucks@usgs.gov)
- Description
- Sources Sought The U. S. Geological Survey (USGS) is conducting market research to determine the availability of qualified businesses capable of providing in-situ fluorometers as described in the attached Salient Characteristics. This sources sought announcement is not a request for quote or proposal and the Government is not committed to award of a purchase order or contract pursuant to this announcement. The information resulting from this market research is simply for planning purposes to assist the Government in determining its acquisition strategy. The Government will not pay for any costs incurred in the preparation of information for responding to this notice. The North American Industry Classification System (NAICS) code - 334516, Analytical Laboratory Instrument Manufacturing and associated size standard 1,000 employees apply to this announcement. All responsible sources may submit a brochure and/or technical specifications detailing the ability of their product to meet the Salient Characteristics included in this announcement. Responses to this announcement shall only be accepted through electronic mail addressed to dallan-loucks@usgs.gov and must be uploaded and received in their entirety no later than 07/13/2021 1500 ES. Responses submitted by hardcopy shall not be accepted or considered. Submersible Fluorometer: Salient Characteristics The Water Mission Area (WMA) Water Quality Program (WQP) Proxies Project requires the procurement of multiple submersible fluorometers to carry out planned field work in support of project goals and objectives. The minimum necessary salient characteristics of the fluorometric sensors that are needed are as follows: A) a single submersible unit that can collect fluorometric information from up to SIX independent optical sensors (each set for discrete excitation/emission wavelength pairs), plus an internal temperature sensor; B) Specific fluorometric sensors needed include those for: turbidity, fluorescent dissolved organic matter (FDOM), chlorophyll (with blue excitation optics), fluorescein, refined fuels, and optical brighteners (custom) C) The custom `optical brightener� sensor must conform to an excitation window of 340-380 nm and an emission window of 400-440 nm D) the primary unit must compatible with a submersible battery for self-contained extended deployment (e.g. 30 days) E) Capable of continuous data capture/ storage with integrated firmware F) the primary unit must include a mechanical wiper and copper antifouling plate to mitigate biofouling during deployment
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/6fa6ad58b2d14d56b69069d9ebf1230a/view)
- Record
- SN06053089-F 20210709/210707230112 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |