Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JULY 09, 2021 SAM #7160
SOURCES SOUGHT

65 -- 509-21-3-528-0299 Wall Mounted UV Lights (VA-21-00065087)

Notice Date
7/7/2021 5:51:30 PM
 
Notice Type
Sources Sought
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
247-NETWORK CONTRACT OFFICE 7 (36C247) AUGUSTA GA 30904 USA
 
ZIP Code
30904
 
Solicitation Number
36C24721Q0959
 
Response Due
7/9/2021 12:00:00 PM
 
Archive Date
09/07/2021
 
Point of Contact
Contracting Officer, Joseph Locke, Phone: 803-776-4000 x7814
 
E-Mail Address
joseph.locke@va.gov
(joseph.locke@va.gov)
 
Awardee
null
 
Description
This is a sources sought announcement only. All responses will be used for market analysis in determining the availability of potential qualified businesses that may be used to determine appropriate acquisition strategy. No solicitation is being issued at this time but may be issued later. The Columbia Healthcare VA System (WJB Dorn VA Medical Center) located at 6439 Garners Ferry Road, Columbia, SC 29209 on behalf of the Augusta, VAMC is seeking Service Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB) and vendors falling into other socioeconomic Small Business (SB) categories to provide wall mounted UV lights. The offeror must meet or exceed all stated salient characteristics identified below. Interested offerors are encouraged to respond to this notice via e-mail and provide their companies name and associated DUNS number. This notice will be posted for a period of 2 business days, closing on Friday, July 9, 2021 at 3pm EST. Questions regarding this notice should be forwarded to Joseph Locke via e-mail at joseph.locke@va.gov SALIENT CHARACTERISTICS: System must meet or exceed all stated salient characteristics identified below: One (1) remote, wireless Ultraviolet C (UVC) challenge calibration sensor/s that measure both direct and indirect/incident UVC energy one (1) required for calibration of multiple rooms. Equipment must have the ability to measure, record, confirm and then report the necessary dosage is delivered to any target in the room being treated. Equipment must have the ability to deliver repeatable room disinfection results without being operator dependent. Equipment must have the ability to Measure, Record and Report both direct and indirect/incident prescribed lethal UVC energy dose to the system host of any delivered UVC dose at any required targeted area of disinfection for proof of compliance and confirmation of room disinfection Wall mounted tablet remote control interface with multiple, customizable, and programmable UVC lethal doses of desired pathogens Voltage 120 (Volts Alternating Current) 7 amperes (AMPS) per fixture Frequency 50/60 Hertz (HZ) Exterior Dimensions Length (L): 72 in. (182.88 cm) Width (W): 14.5 in. (36.83 cm) Depth (D): 14.5 in. (36.83 cm) Fixture Weight 56 pounds each Equipment must have the ability to disinfect/sanitize/cleanse the following: COVID-19, Prions, Bacterial spores (C. Difficile), Mycobacteria, Small, non-enveloped viruses (nor, polio, EV-D68), Fungal spores, Gram-negative bacilli (Acinetobacter), Vegetative fungi and algae, large, non-enveloped viruses, Gram-positive bacteria (MRSA, VRE); Enveloped viruses (Ebola, MERS-CoV). Steady state mercury vapor technology producing 200-300 NM (Nanometers) with peak UVC at 253.7 NM Mercury vapor lamps that do not produce ozone 185 Nanometers (NM) ozone block/ filter on mercury vapor lamps System must be able to confirm lethal UVC dose and eliminate shadow areas Customizable dose dependent disinfection cycles Must be programmable with multiple dose target settings. One (1) (or more) door safety sensor/s Emergency shut-off in case of an emergency Self-contained computer Data capture system software & reporting with cellular connectivity to transmit disinfection job report data to the reporting portal as required including room treated, cycle time, dose delivered, individual sensor readings and operator identification all for proof of compliance SYSTEM COMPONENTS: System Components supplied with each package (fixture type and quantity vary by application and package): Quantity (2) High Output Single Lamp UVC Fixture with Ultra-Reflector, ballast, and lamp. or Quantity (2, 4, 6, or 8) High Output Double Lamp UVC Fixture with Ultra-Reflector, ballasts, and lamps; and Quantity (1) Wall mounted Smart Touchscreen Control. Quantity (2) Red E-Stop Switches with Wall Plates. Quantity (2) Sets of Door Contacts with Magnets. Quantity (1) Remote mounted Control Box (usually mounted above the ceiling) Quantity (1) USB cable. Quantity (1) Smart Touchscreen Power Cable; and Quantity (1) Special installation screwdriver.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/85aa46a27bc1411d9abcd2f9802e9308/view)
 
Place of Performance
Address: Charlie Norwood VA Medical Center 1 Freedom Way Augusta, GA 30904, Augusta
 
Record
SN06054218-F 20210709/210707230120 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.